DALI (Digital Addressable Lighting Interface)
A standard two-wire bus for lighting control, defined in IEC 62386, on which each driver or ballast has its own address. Controllers can dim lamps individually and read back faults and lamp hours.
DAQ (data acquisition)
Measuring signals from sensors and turning them into digital data a computer can store and analyse, often at high sampling rates. DAQ systems are used for testing and for capturing fast events that slower telemetry would miss.
Dashboard
A screen that shows live readings, trends, alarms and controls together, so people see a site’s state at a glance. Good dashboards are built for one job or one role rather than showing every value.
In Hermetry Hermetry boards show live device data, alarms, maps, process drawings and 3D views. More about Dashboard
Data aggregation
Combining many readings into fewer values, such as an hourly average, a daily total or the minimum and maximum of a shift. Aggregation makes long periods fast to chart and cheap to store, at the cost of detail.
Data compression
Making data smaller for sending or storing, by encoding it more efficiently or by keeping only changes. In time-series data, compression often removes points that lie on a straight line between their neighbours.
Data contextualisation
Attaching meaning to raw values: which machine, which unit, which product batch and which shift a reading belongs to. Context turns a column of numbers into data people can compare and act on.
Data diode
A hardware device that lets data flow in one direction only, for example from a control network out to a business network, with no physical path back. It lets data be shared without opening a way in.
Data lake
A store that keeps large amounts of raw data in its original form, from many sources, for later analysis. It is flexible but needs good naming and metadata, or it turns into a pile nobody can use.
In Hermetry To keep every reading in a data lake of your own, a Hermetry flow can forward it after saving, by HTTP request, MQTT out or webhook. More about Data lake
Data logger
A device that records readings at intervals and stores them, for later download or for sending in batches. In IoT, data loggers often double as gateways that also send live values.
Data model
The agreed structure of data: what kinds of things exist, what properties they have and how they relate. A shared data model lets dashboards, rules and integrations work the same across thousands of devices.
Data normalisation
Bringing data from different devices into one consistent form: the same units, names, time zone and number formats. It is needed before data from different makers can be compared or combined.
Data pipeline
The chain of steps that moves data from devices to where it is used: ingestion, decoding, checking, enrichment, storage and forwarding. Each step can be watched for delays and errors.
Data point
A single value with its time, such as one temperature reading. In building automation the term also means a named signal, like a room temperature or a valve position, that a controller exposes.
Data quality
How fit data is for use: complete, accurate, on time and consistent. Missing readings, stuck values and wrong units are common IoT quality problems, and quality flags help users know which data to trust.
Data rate (LoRaWAN DR)
A numbered setting in LoRaWAN, DR0 to DR15, that stands for a spreading factor and bandwidth pair in a given region. Higher data rates send faster and use less airtime but reach less far.
In Hermetry Hermetry’s network server manages data rates with ADR and the MAC commands that go with it. More about Data rate
Data residency
The requirement that data is stored and processed in a particular country or region, often set by law or by a customer’s policy. It decides which cloud region or on-premises installation a project can use.
In Hermetry Every Hermetry organisation has one home region, where its data lives; the docs explain what stays in it and how to check. More about Data residency
Data retention
How long readings and events are kept before they are deleted or reduced to summaries. Raw readings are often kept for months and hourly or daily summaries for years.
In Hermetry Hermetry has retention classes of 7, 30, 90, 365 and 1,095 days: raw readings are kept short, and their summaries are kept for the whole retention period. More about Data retention
dBi
Antenna gain in decibels compared with an isotropic antenna, an ideal antenna that radiates equally in all directions. A 3 dBi antenna sends twice the power in its best direction as the isotropic one would.
dBm
Power in decibels relative to one milliwatt: 0 dBm is 1 mW, 14 dBm about 25 mW and −120 dBm a tiny received signal. Each 3 dB step doubles or halves the power, which makes link budgets easy to add up.
DCS (distributed control system)
A control system for large continuous processes, such as refineries and power plants, in which controllers are spread across the plant but engineered and operated as one system. It combines control, operator screens and history in one integrated package.
DDS (Data Distribution Service)
A standard publish-subscribe middleware for real-time systems, in which applications share data by topics with quality-of-service settings. It is used in robotics, vehicles and defence systems where timing matters.
Dead reckoning
Estimating position from the last known point, the direction and the distance travelled, using motion sensors when satellite positioning is lost, such as in tunnels or warehouses. Its error grows with distance, so the estimate is corrected as soon as a satellite fix or a known landmark is available again.
Deadband
A band around a value inside which changes are ignored. In reporting, a device sends only when the value moves more than the deadband; in alarms, a deadband stops an alarm from switching on and off around its limit.
Debounce
Waiting until a condition has held for a set time before acting on it, so a single spike or a contact bounce does not raise an alarm. A debounce of 2 minutes means "only if it stays above the limit for 2 minutes".
In Hermetry Hermetry alarm rules can debounce by readings in a row or by seconds of device time. More about Debounce
Decommissioning
Taking a device out of service properly: removing it from the platform, revoking its credentials and keys, and keeping or deleting its data as required. Forgotten devices with live credentials are a security risk.
Deep sleep
A low-power state in which a device switches off almost everything except a timer or wake-up input, drawing only microamps. Battery sensors spend most of their life in deep sleep and wake briefly to measure and send.
Defence in depth
Protecting a system with several independent layers, such as network segmentation, strong sign-in, encryption, monitoring and backups, so that one failed layer does not expose everything. It is a central idea of industrial security standards such as IEC 62443.
Delta T
The temperature difference between the supply and return of a heating or cooling circuit. A delta T well below design usually means too much water is being pumped, wasting energy in pumps and chillers.
Demand charge
The part of an electricity bill based on the highest power drawn in a short interval, often 15 minutes, rather than on energy used. One short peak can set the charge for a whole month, which is why sites watch their load curve.
In Hermetry The energy meter use case shows Hermetry reading a store’s main meter as demand nears its contracted maximum. More about Demand charge
Demand response
Changing electricity use in answer to a signal from the grid or a price, for example by switching off non-essential loads during a peak. Connected meters and controls make it possible to respond automatically and to prove the reduction.
Demand-controlled ventilation
Adjusting how much outside air a building takes in according to how many people are there, usually measured by CO₂ sensors. Rooms get fresh air when they are used and save energy when they are empty.
DER (distributed energy resource)
A small energy source or store connected near where energy is used, such as rooftop solar, batteries, small generators and controllable loads. Grids increasingly monitor and coordinate many DERs together.
DevAddr (device address)
The 32-bit address a LoRaWAN device uses in every message during a session, assigned at join for OTAA or set beforehand for ABP. Unlike the DevEUI it is not globally unique, so the network also checks each message’s integrity code.
In Hermetry An ABP device is registered in Hermetry with its DevAddr and its two session keys, and Hermetry handles its frame counters. More about DevAddr
Device attestation
A device proving to a server that it is genuine and running approved software, using keys kept in protected hardware such as a secure element or TPM. It stops cloned devices and tampered firmware from joining a fleet.
Device class (LoRaWAN class A, B, C)
How a LoRaWAN device listens for downlinks. Class A listens only briefly after each uplink and saves the most battery; class B also listens at scheduled times; class C listens almost always and is usually mains-powered.
In Hermetry Hermetry supports class A and class C; class B is not supported. More about Device class
Device discovery
Finding devices on a network automatically, such as scanning a Modbus bus for responding addresses or asking BACnet devices to announce themselves. It speeds up installation on sites with many devices.
Device identity
What lets a platform know which device it is talking to, such as a unique identifier backed by a key or certificate that cannot be copied. Strong identity is the base of secure provisioning, data trust and access control.
In Hermetry Hermetry protects both steps: a device must prove who it is before its data is accepted, and an organisation must prove it owns a device before adding it. More about Device identity
Device management
Everything needed to run a fleet of devices: registering them, configuring them, watching their health, updating firmware and retiring them. It is often harder than collecting the data itself.
Device profile
A template describing a type of device: its data fields, units, decoder, alarms and commands. Every device of that type inherits the profile, so a change is made once instead of per device.
In Hermetry In Hermetry a device profile describes how one kind of device behaves; every device uses exactly one, and follows it when it changes. More about Device profile
Device shadow
A stored copy of a device’s last reported state and its desired state on the server. Applications read and write the shadow, and the device catches up with the desired state when it next connects.
Device twin
Another name for a device shadow: the platform’s copy of a device’s reported state and desired settings. See device shadow.
Device-to-cloud message
A message sent from a device to the platform, such as a reading, an event or a status report. It is the most common direction of traffic in IoT.
Dew point
The temperature at which air becomes saturated and water starts to condense, calculated from temperature and relative humidity. It matters for cold stores, compressed air, buildings and electronics, where condensation causes damage.
DGA (dissolved gas analysis)
Analysing the gases dissolved in a transformer’s insulating oil to detect faults such as overheating and arcing long before failure. Online DGA monitors send these readings continuously.
DHCP (Dynamic Host Configuration Protocol)
The protocol that gives devices on an IP network their address and network settings automatically when they connect. Industrial devices are often given fixed addresses or DHCP reservations so they can always be found.
Differential pressure
The difference in pressure between two points, used to measure flow across an orifice, how clogged a filter is, the level in a closed tank or whether a cleanroom is kept at higher pressure than its neighbours. A differential pressure transmitter has two pressure ports and reports the difference between them.
In Hermetry The cleanroom use case watches room pressure cascades in Hermetry, with door-aware alarms and named acknowledgements. More about Differential pressure
Digital input
An input that reads an on or off signal, such as a door contact, a pump’s running signal or an alarm relay. Many digital inputs can also count pulses from meters.
Digital output
An output that switches something on or off, usually through a relay or a transistor: a pump, a siren, a valve. Remote control of an output is a command and deserves the same care as any action on equipment.
Digital signature
A value made with a private key that proves who created data and that it has not been changed since. Anyone with the matching public key can check it; firmware updates and certificates rely on signatures.
Digital thread
A connected record of a product’s data across its life, from design and production to service, so information flows between stages instead of being re-entered. IoT data from products in use closes the loop back to design.
Digital twin
A live digital model of a physical asset or site, kept up to date with its readings, so people can see and analyse it as it is now. The word is used for anything from a 3D drawing with live values to a full physics simulation.
In Hermetry Hermetry Twin models your sites as a tree of buildings, floors, rooms, lines and machines, with each device placed in it and live status on tables, maps and views. More about Digital twin
DIN rail
A standard 35 mm metal rail used to mount controllers, gateways, power supplies and terminal blocks inside electrical cabinets. Most industrial IoT hardware is made to clip onto it.
Direct-to-device satellite
Satellite connectivity that reaches ordinary or lightly modified IoT devices directly, without a dish or ground terminal, often using mobile network standards. It covers places with no mobile network, such as oceans, deserts and remote farms.
Disaster recovery
Planning and practising how to restore a system after a serious failure, such as a data centre loss. Two figures define it: how much recent data may be lost (RPO) and how quickly service must return (RTO).
Discrete manufacturing
Making distinct items that can be counted, such as cars, phones and furniture, as opposed to process industries that make products in continuous flows or batches. Monitoring focuses on part counts, cycle times and machine states.
Dissolved oxygen
The amount of oxygen dissolved in water, in milligrams per litre. Wastewater plants control aeration by it, one of their largest energy uses, and fish farms and rivers need enough of it for life.
District heating
A network that supplies heat from central plants to many buildings through insulated pipes carrying hot water. Heat meters, temperatures and pressures across the network show losses and customer use.
DMA (district metered area)
A part of a water network with metered inlets and outlets, so the water going in can be compared with the water used. DMAs are the standard way to find which part of a network is leaking.
In Hermetry The water network use case shows DMA inflow and minimum night flow watched in Hermetry, with a burst alarm. More about DMA
DNP3
A protocol used between control centres and outstations in electricity and water utilities. It handles unreliable links well, reports by exception and can time-stamp events at the source.
DNS (Domain Name System)
The system that turns names like a server’s address into IP addresses. Devices that rely on fixed IP addresses instead of names can break when a service moves.
In Hermetry To use your own domain with Hermetry, you create the DNS records the docs list; Hermetry verifies them and gets the certificate itself. More about DNS
Door contact sensor
A sensor, usually a magnet and a reed switch, that reports whether a door, lid or hatch is open or closed. In cold rooms and cabinets it explains temperature rises and shows unauthorised access.
DoS (denial of service)
An attack that makes a service unavailable by overloading it or a network link, often from many sources at once (a distributed attack). Badly secured IoT devices have been recruited in large numbers to carry out such attacks.
Downlink
A message from the network or the platform to a device, such as a command or a new setting. In LoRaWAN, a class A device can only receive a downlink right after it sends an uplink.
In Hermetry Hermetry queues LoRaWAN downlinks as commands and sends them through its network server; a downlink can ask the device to confirm it. More about Downlink
Downsampling
Reducing data to fewer points, for example turning one reading a minute into hourly averages, minimums and maximums. It keeps long-term charts fast and storage small while keeping the shape of the data.
In Hermetry Hermetry reads minute, hour or day summaries depending on the time window, so long charts stay fast. More about Downsampling
Downtime
Time when a machine, line or service is not available. Planned downtime is scheduled, such as maintenance; unplanned downtime comes from failures and is what monitoring aims to reduce.
Drive-by meter reading
Reading radio-equipped meters from a vehicle that drives past them, collecting many readings in one trip. It is cheaper than visiting each meter but gives only occasional readings, unlike fixed networks.
Dry contact (volt-free contact)
A switch contact that carries no voltage of its own, such as an alarm relay inside a panel. Whatever reads it supplies the voltage, so it can be wired to almost any digital input.
DTLS (Datagram Transport Layer Security)
The version of TLS for connectionless traffic such as UDP. It secures CoAP and other lightweight protocols that do not use TCP.
Dual SIM
A device that holds two SIM cards, or profiles, from different networks so it can switch if one fails. It is common in gateways and routers that must stay online.
Duty cycle
The share of time a radio may transmit on a channel. Many channels of the European 868 MHz band allow 1 %, about 36 seconds of transmitting in any hour, which limits how often a LoRaWAN device can send.
In Hermetry The LoRaWAN airtime calculator on our tools page shows how many messages fit in a 1 % duty cycle. Open the tool
Dwell time
How long something stays in one place, such as a container at a port, a truck at a dock or a pallet in a zone. Long dwell times point to bottlenecks; in radio regulations the term also means how long a transmitter may stay on one channel.
See your own devices on Hermetry
Connect a first device, watch its readings live and set an alarm on it. Start free, or ask us to set it up with you.