IoT and SCADA terms starting with E include Edge computing, eSIM, EU868 and EUI-64. Each of the 41 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.
Showing 0 terms on E · Clear
41 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)
E
EAP-TLS
A network sign-in method in which a device proves its identity with a certificate instead of a password, using TLS inside the Extensible Authentication Protocol. It is the usual choice for putting unattended devices on an enterprise Wi-Fi or wired network that checks every client.
ECC (elliptic-curve cryptography)
A family of public-key algorithms that reach the same strength as RSA with much shorter keys. Short keys and fast signatures make ECC the common choice for device certificates and secure elements on small microcontrollers.
Edge AI
Running a trained machine-learning model on the device or gateway itself instead of in the cloud. It cuts latency and data volume, keeps working when the connection drops, and lets a camera or vibration sensor send a result rather than raw data.
Edge computing
Processing data close to where it is produced, on a gateway or a local server, instead of sending everything to the cloud. It cuts traffic, keeps working when the connection drops and reacts faster.
Edge gateway
A device on site that reads local equipment over serial, fieldbus or local network protocols and forwards the data, often after filtering or buffering it. It is the bridge between the field and the platform.
In Hermetry Hermetry Edge runs on the gateways and routers Hermetry supports, reads field devices and can keep data locally during outages, depending on the model. More about Edge gateway
eDRX (extended discontinuous reception)
A cellular power-saving feature of LTE-M and NB-IoT in which a device listens for the network only at long, agreed intervals, from seconds to hours. It saves battery while still letting the network reach the device, unlike PSM where the device cannot be reached at all.
EEPROM
Non-volatile memory that keeps small amounts of data, such as settings, calibration values and counters, when the power is off, and can be rewritten byte by byte. It wears out after a limited number of writes, so firmware avoids writing it too often.
EER (energy efficiency ratio)
The cooling output of an air conditioner or chiller divided by its electrical input, at stated test conditions. In imperial units it is BTU per hour per watt; a higher EER means less electricity for the same cooling.
Electrical conductivity (EC)
How easily a liquid carries an electric current, which rises with the amount of dissolved salts. It is used to check nutrient strength in hydroponics and fertigation, and salinity and contamination in water.
Electromagnetic flow meter
A flow meter that measures the voltage induced when a conductive liquid flows through a magnetic field, which is proportional to its velocity. It has no moving parts and no pressure loss, which is why water and wastewater networks use it widely.
Embedded system
A computer built into a product to do one job, such as a sensor, meter or controller, usually around a microcontroller with fixed firmware. Most IoT devices are embedded systems with a radio or network port added.
EMC (electromagnetic compatibility)
The ability of an electronic device to work properly near other equipment without disturbing it or being disturbed. Industrial devices are tested for emissions and immunity to standard levels before they may be sold in most markets.
Emission factor
A number that converts an activity into greenhouse gas emissions, such as kilograms of CO₂ per kWh of grid electricity or per litre of diesel. Energy data multiplied by the right factors gives a site’s carbon footprint.
EMS (energy management system)
Software, often with meters and controllers, that measures, reports and controls energy use across a site or a group of sites. It shows where energy goes, finds waste and can shift or limit loads to cut peaks and cost.
Encoder (rotary)
A sensor that turns the rotation of a shaft into pulses or a digital position, so a controller knows speed, direction and angle. Incremental encoders count steps from a reference; absolute encoders report the exact position even after a power loss.
Encryption at rest
Encrypting stored data, such as databases, backups and files, so that a stolen disk or copy cannot be read without the key. It complements encryption in transit, which protects data while it moves.
Encryption in transit
Encrypting data while it travels between a device, a gateway and the cloud, usually with TLS or a VPN. It stops anyone on the path from reading or changing readings and commands.
End device (LoRaWAN)
A sensor or actuator that talks to a LoRaWAN network over the air, as opposed to the gateways that relay its frames. End devices are identified by their DevEUI and join the network through OTAA or ABP.
End-to-end encryption
Encryption that is applied by the sender and removed only by the final recipient, so no system in between, such as a gateway or broker, can read the content. LoRaWAN payloads, for example, are encrypted end to end between the device and the application.
Energy baseline
A reference figure for how much energy a site or machine uses under normal conditions, against which savings are measured. A fair baseline adjusts for things like weather and production volume, so savings are not confused with a warm winter.
Energy harvesting
Powering a device from its surroundings, such as light, heat differences, vibration or radio waves, instead of from a battery alone. It suits sensors that send small amounts of data in places where changing batteries is costly.
Energy meter
A meter that measures electrical energy in kWh and often power, voltage, current and power factor too. Meters with a communication port, usually Modbus or M-Bus, can be read remotely.
In Hermetry The energy meter use case reads site meters into Hermetry, with demand, power factor and data completeness alarms. More about Energy meter
Energy monitoring
Measuring energy use by site, building, line or machine over time, so waste and peaks can be found. It is the basis of energy management and of savings that can be proven.
EnPI (energy performance indicator)
A measure of energy performance chosen by an organisation, such as kWh per tonne produced or per square metre. ISO 50001 uses EnPIs, compared with a baseline, to show whether energy performance is really improving.
Epoch time (Unix time)
A way of writing a moment as the number of seconds, or milliseconds, since 1 January 1970 at 00:00 UTC. Devices and APIs use it because it is a single number, free of time zones and date formats.
Escalation (alarm)
Passing an alarm on to further people or teams when nobody acknowledges or resolves it within a set time. Escalation chains make sure a critical alarm at night reaches someone who can act.
eSIM
A SIM that is built into the device and can receive operator profiles over the air, so changing operator does not require a visit to swap a card. Industrial devices usually use it in a soldered form.
In Hermetry Hermetry manages the eSIM profiles of supported routers, which reach it over their mobile uplink. More about eSIM
Ethernet
The common family of wired network standards (IEEE 802.3) for local networks, from 10 Mbit/s to many Gbit/s over copper or fibre. Industrial Ethernet variants, rugged switches and Power over Ethernet make it the backbone of most plant and building networks.
Ethernet-APL (advanced physical layer)
A two-wire Ethernet physical layer for process plants that carries data and power over long cable runs and can be made intrinsically safe. It brings Ethernet down to field instruments in hazardous areas, where 4–20 mA and HART used to be the only options.
EtherNet/IP
An industrial Ethernet protocol that carries the Common Industrial Protocol over standard Ethernet and IP. It connects controllers, drives and I/O on the plant floor.
ETL (extract, transform, load)
The process of taking data out of one system, reshaping and cleaning it, and loading it into another, such as a data warehouse. In IoT it often means moving cleaned telemetry from an operational platform into analytics or reporting tools.
EU868
The LoRaWAN regional plan for the 863–870 MHz band used in Europe, with three default 125 kHz channels and duty-cycle limits per sub-band. Devices and gateways must use the plan of the region where they operate.
In Hermetry Hermetry’s LoRaWAN docs use the EU868 plan (Europe, 863–870 MHz) to show channels, data rates, payload sizes and duty-cycle limits. More about EU868
EUI-64 (DevEUI, JoinEUI)
A globally unique 64-bit identifier. In LoRaWAN, each device has a DevEUI and points to a JoinEUI; together with the device’s root key they identify it when it joins a network.
In Hermetry A LoRaWAN device that joins over the air is registered in Hermetry with its DevEUI, JoinEUI and AppKey. More about EUI-64
eUICC
The secure chip inside an eSIM that can hold several operator profiles and switch between them remotely, following standard procedures for consumer or machine devices. It is what lets a device in the field change mobile operator without anyone swapping a card.
EV charger (charging point)
Equipment that delivers electricity to an electric vehicle, from slow AC wall boxes to fast DC chargers. Connected chargers report their state, energy and faults and accept limits from a back office or a site energy manager.
Evapotranspiration (ET)
The water lost from soil and plants to the air through evaporation and plant transpiration, usually given in millimetres per day. Irrigation systems use it, together with rainfall and soil moisture, to decide how much water a crop actually needs.
Event
Something that happened at a point in time, such as a door opening, a status change or an alarm, as opposed to a regular reading. Events usually carry a type, a time and a few details.
Event-driven architecture
A design in which systems react to events, such as a new reading, a door opening or an alarm, as they happen, instead of asking each other at fixed times. It keeps traffic low and reactions fast, which suits large fleets of devices.
Explosion-proof enclosure (flameproof, Ex d)
A housing strong enough to contain an explosion inside it and built so that hot gases cool before they escape, so the surrounding atmosphere is not ignited. It is one of the protection methods allowed for electrical equipment in hazardous areas.
Exponential smoothing
A way of smoothing a noisy series in which each new value is a weighted mix of the latest reading and the previous smoothed value. Recent readings count most, older ones fade gradually, and it needs almost no memory, so it fits small devices well.
Extended coverage (coverage enhancement)
A feature of LTE-M and NB-IoT in which a device in a poor spot, such as a basement, repeats its transmissions many times so the network can still decode them. It extends reach deep indoors at the cost of extra airtime and battery.
See your own devices on Hermetry
Connect a first device, watch its readings live and set an alarm on it. Start free, or ask us to set it up with you.