New: the AI firewall watches the whole platform and explains each incident in plain words. See how it works

IoT glossary: S

IoT and SCADA terms starting with S: Sampling rate, Satellite IoT, SBOM, SCADA and 66 more, each with a plain definition.

IoT and SCADA terms starting with S include SCADA, Smart meter, SMS and SNMP. Each of the 70 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.

70 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)

S

Sampling rate

How often a value is measured, such as once a second or once every 15 minutes. It should follow how fast the thing changes and what the data is used for.

Data and analyticsRelated: Telemetry, Report by exception, Downsampling

Satellite IoT

Connecting devices through satellites where there is no cellular or radio coverage, such as at sea, on pipelines or in remote farmland. Low-earth-orbit services suit small, infrequent messages; 3GPP has also added satellite links (non-terrestrial networks) to NB-IoT and LTE-M.

ConnectivityRelated: NTN, LPWAN, Backhaul

SBOM (software bill of materials)

A list of every software component and version inside a product, including open-source libraries. When a new vulnerability is published, an SBOM tells you at once which devices contain the affected component.

SecurityRelated: Vulnerability management, Firmware

SCADA (supervisory control and data acquisition)

A system that collects data from field equipment across a site or many sites, shows it on process screens, raises alarms and lets operators send commands. It sits above the local controllers, which keep running the process if the SCADA connection is lost.

In Hermetry Hermetry has a SCADA designer with an animated symbol library, in 2D and 3D, in the browser. More about SCADA

Automation and controlRelated: HMI, Historian, PLC

Scaling (engineering units)

Converting a raw value into a real unit, such as turning a 4–20 mA signal or a register value of 0–4095 into 0–10 bar. A wrong scale gives plausible-looking but wrong numbers.

Devices and sensorsRelated: Analog input, Modbus register, Current loop

Schema (data)

A description of the shape data must have: which fields exist, their types, units and allowed ranges. Agreeing on a schema between devices and the platform catches malformed messages early and lets dashboards and rules rely on the data.

Data and analyticsRelated: JSON, Payload, Codec

SDK (software development kit)

A set of libraries, examples and tools for building software against a platform or a chip. Device SDKs typically handle connecting, authentication and message formatting, so firmware developers can focus on the sensor logic.

Data and analyticsRelated: API, Firmware, MQTT

Secure boot

A start-up check in which each piece of firmware verifies the digital signature of the next before running it, starting from code that cannot be changed. A device with secure boot refuses to run firmware that was tampered with or not signed by its maker.

SecurityRelated: Firmware signing, Root of trust, OTA

Secure element

A tamper-resistant chip that stores keys and performs cryptographic operations without ever exposing the keys to the main processor. It gives a device a strong, hard-to-copy identity and is common in smart meters, payment terminals and SIM cards.

SecurityRelated: Root of trust, TPM, X.509 certificate

Sensor

A device that measures a physical quantity, such as temperature, pressure, level, flow or vibration, and turns it into a signal or a number. Many sensors include electronics that linearise, compensate and digitise the reading before sending it on.

Devices and sensorsRelated: Analog input, Telemetry

Sensor drift

A slow change in a sensor’s readings over time even though the measured quantity has not changed, caused by ageing, fouling or temperature. Drift is caught by comparing against a reference or a neighbouring sensor and corrected by recalibration.

Devices and sensorsRelated: Calibration, Measurement uncertainty, Anomaly detection

Sensor fusion

Combining readings from several sensors to get a better estimate than any one alone, such as an accelerometer and gyroscope giving a stable orientation, or GNSS and wheel speed giving position in a tunnel. Filters such as the Kalman filter weigh each sensor by how much it can be trusted at that moment.

Data and analyticsRelated: GNSS, Virtual sensor

Sensor hub

A low-power processor that reads several sensors continuously and only wakes the main processor when something interesting happens. It lets a device notice movement or a threshold without the power cost of running everything all the time.

Devices and sensorsRelated: MCU, Sleep mode

Service discovery

Letting devices and applications find each other on a network without fixed addresses, for example through multicast DNS on a local network. It makes plug-in setup easier but should be limited on industrial networks for security.

ConnectivityRelated: DNS, Zero-touch provisioning, UDP

Session keys (LoRaWAN)

The keys a LoRaWAN device and the network use for one session: one for network integrity and one for application payload encryption. OTAA derives new ones at every join.

ConnectivityRelated: OTAA, ABP, AES-128

Setpoint

The target value a control loop works to hold, such as 21 °C or 3.5 bar. Changing a setpoint remotely changes how equipment runs, so it deserves rights and logging.

In Hermetry A set point card on a Hermetry board sends a new set point to a device as a command. More about Setpoint

Automation and controlRelated: PID controller, Command, Device shadow

Sewer overflow monitoring

Measuring level and spills at points where a sewer can overflow into rivers or streets, especially in combined sewers that carry rainwater too. Regulators increasingly require spill counts and durations, which only continuous monitoring can provide.

WaterRelated: Ultrasonic level sensor, Wastewater treatment, Rain gauge

Shelf-life monitoring

Using the temperature history of perishable goods to estimate how much of their shelf life is left, instead of relying on a fixed date. A product that spent hours too warm in transit can be sold or used first.

LogisticsRelated: Cold chain, Temperature excursion, MKT

Shunt resistor

A small, precise resistor in a current path whose voltage drop shows how much current flows. It is a simple, cheap way to measure DC current in batteries, solar systems and power supplies, but unlike a current transformer it is in contact with the circuit.

Devices and sensorsRelated: CT, Energy meter, SoC

Signal conditioning

Preparing a raw sensor signal for measurement: amplifying it, filtering noise, isolating it electrically and converting it to a standard form such as 4–20 mA. Thermocouples, strain gauges and RTDs all need conditioning before a converter can read them.

Devices and sensorsRelated: Current loop, Thermocouple, Analog input

Signal tower (stack light)

The column of coloured lights on a machine that shows its state, typically green running, yellow warning and red stopped or faulted. Reading the tower’s signals is one of the simplest ways to monitor older machines without touching their controllers.

ManufacturingRelated: Digital input, OEE, Retrofit

SIL (safety integrity level)

A level from 1 to 4 in IEC 61508 and IEC 61511 for how much risk reduction a safety function must provide. Safety functions are handled by certified local systems, not by monitoring software.

StandardsRelated: Interlock, Fail-safe

SIM

The module that identifies a device to a mobile network and holds its subscription. IoT SIMs come as removable cards, soldered chips or eSIMs.

ConnectivityRelated: eSIM, APN, Cellular IoT

Single-board computer

A complete small computer on one circuit board, running a full operating system such as Linux. It is often used for prototypes and as an edge gateway, where it can run protocol converters and local logic.

Devices and sensorsRelated: Edge gateway, MCU, SoC

SIS (safety instrumented system)

An independent control system whose only job is to bring a process to a safe state when it goes dangerously wrong, for example by closing a valve on high pressure. It is designed to IEC 61511 and kept separate from the normal control system and from remote monitoring.

Automation and controlRelated: SIL, Interlock, Fail-safe

SLA (service level agreement)

A written commitment from a provider about the level of service, such as 99.9 % availability per month, support response times and what happens if they are missed. Reading what counts as downtime is as important as the percentage.

OperationsRelated: Uptime, Availability, RPO and RTO

SLD (single-line diagram)

A simplified drawing of an electrical system in which each three-phase circuit is shown as one line, with its breakers, transformers, busbars and loads. SCADA screens for power distribution are usually built on the single-line diagram.

EnergyRelated: Substation, SCADA, P&ID

Sleep mode

A low-power state in which a device turns off most of its circuits and wakes on a timer or an event. Battery sensors spend nearly all their life asleep, drawing a few microamps, so the sleep current largely decides battery life.

Devices and sensorsRelated: Quiescent current, PSM, Battery life

Smart building

A building whose systems, such as HVAC, lighting, access, metering and occupancy sensing, share data so they can be monitored and run together. The usual goals are lower energy use, comfort and less time spent finding faults.

BuildingsRelated: BMS, HVAC, Occupancy sensor

Smart grid

An electricity network that uses measurement and communication throughout, from substations to meters, to balance supply and demand, find faults faster and connect distributed generation such as rooftop solar and batteries. Smart meters, automated substations and grid sensors are its typical IoT devices.

EnergyRelated: Smart meter, Demand response

Smart irrigation

Watering based on measured need rather than a fixed timetable, using soil moisture, weather data and evapotranspiration. Valves and pumps are controlled remotely, and flow meters confirm that the water actually went where it was sent.

AgricultureRelated: Soil moisture sensor, Evapotranspiration, Flow meter

Smart lighting

Lighting that can be dimmed, scheduled and monitored remotely, from office luminaires to street lights. Each controller reports power, burning hours and faults, so failed lamps are found without patrols and energy use drops through dimming.

Smart cityRelated: DALI, Energy monitoring

Smart meter

A utility meter that records consumption in short intervals and sends it remotely, often with two-way communication for tariffs and remote disconnection. Utilities use smart meter data for accurate billing, load planning and finding losses in the network.

EnergyRelated: Energy meter, M-Bus, Load profile

Smart parking

Detecting whether each parking bay is free, with magnetic or radar sensors in the bay or with cameras, and guiding drivers to free spaces. Occupancy data also helps cities set prices and enforcement times.

Smart cityRelated: Occupancy sensor, Video analytics

Smart waste management

Measuring how full bins and containers are, usually with ultrasonic or radar sensors, so collection routes visit only the ones that need emptying. It saves truck kilometres and avoids overflowing bins.

Smart cityRelated: Ultrasonic level sensor

Smoke detector

A sensor that detects smoke, optically by light scattering or by ionisation. Connected detectors report alarms, faults and low batteries remotely, but they complement rather than replace a certified fire alarm system.

BuildingsRelated: Smart building, Alarm

SMS (short message service)

Text messages over the mobile network. In IoT, SMS is used to send alarms to people without a data connection or app, and some devices accept SMS commands or wake-up messages when their data session is down.

In Hermetry Hermetry sends SMS only to phone numbers you name explicitly, with a per-number throttle, quiet hours and opt-outs. More about SMS

ConnectivityRelated: Cellular IoT, Alarm, Notification

SNMP (Simple Network Management Protocol)

A protocol for reading and changing the status of network equipment, UPS units and servers. Version 3 adds authentication and encryption, which earlier versions lack.

In Hermetry Hermetry polls SNMP agents, with SNMPv3 recommended and SNMPv2c available, and needs no MIB file. More about SNMP

ProtocolsRelated: SNMP trap, Polling, UPS

SNMP trap

A message a device sends on its own to report an event, such as a UPS switching to battery, instead of waiting to be polled. Traps arrive at once, but are usually sent only once, so many systems also poll to catch any that were lost.

ProtocolsRelated: SNMP, Event

SNR (signal-to-noise ratio)

How far a signal stands above the background noise, in dB. LoRa can decode signals below the noise level, down to about −20 dB at the slowest spreading factor.

ConnectivityRelated: RSSI, Link budget, Spreading factor

SNTP (Simple Network Time Protocol)

A lighter version of NTP for devices that only need to set their clock from a server, without NTP’s full filtering and clock steering. It gives accuracy in the tens of milliseconds, which is enough for most telemetry timestamps.

ProtocolsRelated: NTP, RTC, Timestamp

SoC (state of charge)

How full a battery is, as a percentage of its current capacity. It is estimated from voltage, counted charge and temperature, and is the basic reading for battery storage, electric vehicles and battery-powered devices.

EnergyRelated: SoH, BESS, Battery life

SoC (system on chip)

A single chip that combines a processor, memory, radio and peripherals. Many IoT modules are built on one, which keeps devices small, cheap and low-power. Do not confuse it with SoC as state of charge.

Devices and sensorsRelated: MCU, Firmware, Single-board computer

SOE (sequence of events)

A record of state changes, such as breaker trips and alarms, time-stamped at the source with millisecond precision. It shows exactly which event came first during a fast incident, which ordinary polling every few seconds cannot do.

Automation and controlRelated: Timestamp, Root cause analysis, IEC 61850

SoH (state of health)

How much capacity a battery has left compared with when it was new, as a percentage. A battery at 80 % SoH holds four fifths of its original energy; tracking SoH tells you when to replace batteries in backup systems and devices.

EnergyRelated: SoC, UPS, BESS

Soil moisture sensor

A probe that measures how much water the soil holds, usually as volumetric water content from the soil’s electrical properties, or as tension, which shows how hard roots must pull. Readings at several depths show whether irrigation reaches the root zone.

AgricultureRelated: Smart irrigation, Evapotranspiration, Precision agriculture

Solar PV (photovoltaics)

Panels that turn sunlight directly into electricity. Monitoring a PV system compares inverter output with irradiance and temperature, so dirty panels, failed strings and inverter faults show up as lost energy rather than going unnoticed.

EnergyRelated: Performance ratio

Sound level monitoring

Measuring noise continuously, usually as A-weighted decibels, dB(A), which follow how people hear. Cities and sites use it to check night-time limits near homes and to find machines that have become noisier, often an early sign of wear.

Smart cityRelated: Vibration monitoring, Threshold

Sparkplug B

An open specification for using MQTT in industrial systems. It fixes the topic structure, a compact binary payload and birth and death messages, so every subscriber knows which devices exist, what they report and whether their data is still current.

ProtocolsRelated: MQTT, UNS, Last will

SPC (statistical process control)

Watching a process with statistics, typically control charts with upper and lower control limits, to tell normal variation from a real change. A run of points trending one way can show a drifting machine before it makes bad parts.

ManufacturingRelated: OEE, Trend

SPI (serial peripheral interface)

A fast, short-distance bus between a microcontroller and chips on the same board, such as radios, flash memory and sensors. It uses separate lines for clock, data out, data in and chip select, and is not meant for cables between devices.

Devices and sensorsRelated: UART, MCU

Split brain

A failure in a redundant system in which the members lose contact with each other and each believes it is the active one, so both accept writes or issue commands. Quorum rules and fencing are used to prevent it.

Data and analyticsRelated: Quorum, High availability, Redundancy

Spreading factor (SF)

In LoRa, how long each symbol is stretched, from SF7 to SF12. Each step up roughly doubles time on air and adds range, at the cost of battery and network capacity.

In Hermetry The LoRaWAN airtime calculator on our tools page shows how time on air grows with each spreading factor. Open the tool

ConnectivityRelated: Data rate, Time on air, ADR

SSL (Secure Sockets Layer)

The predecessor of TLS. All SSL versions are obsolete and insecure; the name lives on in everyday speech, as in SSL certificate, but current connections use TLS 1.2 or 1.3.

SecurityRelated: TLS, X.509 certificate, mTLS

SSO (single sign-on)

Signing in once with a company identity and using several applications without new passwords, through standards such as SAML 2.0 and OpenID Connect. When someone leaves the company and their account is switched off, they lose access to every connected application at once.

In Hermetry Each Hermetry organisation can connect its own SAML 2.0 or OpenID Connect identity provider and keep members in step with SCIM 2.0. More about SSO

SecurityRelated: RBAC, JWT

Stale data

A value that is still shown but is no longer current, because the device stopped reporting. Showing the age of a value, or greying it out, keeps people from acting on old data.

Data and analyticsRelated: Heartbeat, Quality code, Timestamp

Star topology

A network in which every device connects to a central point, such as sensors to a gateway or switches to a core switch. It is simple to manage, and a failed device does not affect the others, but the centre is a single point of failure.

ConnectivityRelated: Mesh network, Ring topology, LoRaWAN

State machine

A model in which a system is always in one of a set of states and moves between them on defined events, such as a pump going from stopped to starting to running. Firmware, alarm handling and process sequences are often written as state machines.

Automation and controlRelated: Interlock, Event, IEC 61131-3

Static IP address

An address that stays the same instead of being assigned anew on each connection. Devices that must be reached from outside, such as a site router, often need one, or a private network or VPN that provides fixed addresses.

ConnectivityRelated: APN, VPN, Remote access

Store and forward

Keeping readings in local memory while the connection is down and sending them, with their original time stamps, once it is back, so no data is lost. How much can be kept depends on the device’s memory and how long the outage lasts.

In Hermetry Readings a device buffers during an outage still land in Hermetry’s history; alarms opened from them are marked Backfilled, and nobody is paged for the past. More about Store and forward

Data and analyticsRelated: Data logger, Edge computing, Queue

Strain gauge

A sensor whose electrical resistance changes as it is stretched or compressed, bonded to a structure or built into a load cell. It is the basis of most weighing systems and of stress measurement on bridges and machines.

Devices and sensorsRelated: Load cell, Structural health monitoring, Signal conditioning

Stream processing

Handling data as it arrives, message by message or in short windows, instead of storing it first and querying it later. Rules engines, live aggregates and real-time alarm checks are forms of stream processing.

Data and analyticsRelated: Rules engine, Ingestion, Time series

Structural health monitoring

Measuring bridges, buildings, tunnels and dams over time with strain gauges, tilt sensors, crack meters and accelerometers, to see how a structure behaves and spot damage early. Long-term data shows slow changes, such as settlement or growing cracks, that inspections can miss.

Smart cityRelated: Strain gauge, Tilt sensor, Vibration monitoring

Sub-metering

Metering parts of a site separately, such as a floor, a line or a tenant, under the main meter. It shows where energy or water actually goes and allows fair cost splitting.

In Hermetry The building HVAC and energy use case brings main and sub-meters into Hermetry with the plant they serve. More about Sub-metering

EnergyRelated: Energy meter, Energy monitoring, CT

Submersible pump

A pump whose motor and pump sit together under the liquid, in boreholes, wells and sewage pits. Because it cannot be seen, monitoring current, run hours, starts per hour and temperature is the main way to spot clogging and wear.

WaterRelated: Run hours, VFD, Pumping station

Substation

Part of an electricity network where voltage is transformed and circuits are switched and protected. Substation automation collects breaker states, measurements and protection events, increasingly over IEC 61850.

In Hermetry The substation use case brings power analysers, transformer temperature, fault indicators and switch positions of secondary substations into Hermetry. More about Substation

EnergyRelated: IEC 61850, SLD, Transformer monitoring

Supercapacitor

A capacitor that stores far more energy than an ordinary one and can be charged and discharged hundreds of thousands of times. In IoT it buffers energy-harvesting sources and covers short current peaks, such as a radio transmission, that a small battery cannot supply.

Devices and sensorsRelated: Energy harvesting, Battery life, UPS

Surge protection (SPD)

Devices that divert short voltage spikes, such as those from lightning or switching, safely to earth before they reach equipment. Outdoor sensors, antennas and long signal cables at remote sites need surge protection on power, data and antenna lines.

Devices and sensorsRelated: RCD, IP rating, Antenna gain

Symmetric encryption

Encryption in which the same secret key locks and unlocks the data, such as AES. It is fast and suits small devices, but both sides must already share the key securely, which is why it is often combined with public-key methods during a handshake.

SecurityRelated: AES-128, PKI, TLS

Syslog

A standard way for devices and servers to send log messages to a central collector, defined in RFC 5424. Routers, firewalls and gateways commonly use syslog, which makes it a simple source for security monitoring.

SecurityRelated: Audit log, SNMP trap

See your own devices on Hermetry

Connect a first device, watch its readings live and set an alarm on it. Start free, or ask us to set it up with you.