IoT and SCADA terms starting with O include OPC UA, OEE, OTA and OTAA. Each of the 41 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.
Showing 0 terms on O · Clear
41 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)
O
OAuth 2.0
An authorisation framework in which an application gets a limited access token instead of the user’s password. It is the usual way third-party tools and integrations get scoped, revocable access to an IoT platform’s API.
OBD-II (on-board diagnostics)
The standard diagnostic port and protocol set in passenger cars and light vehicles, giving access to fault codes and live data such as speed and engine load. Plug-in telematics devices read it for fleet monitoring.
Object detection
A computer vision task that finds and labels objects in an image, such as vehicles, people or parcels, with their positions. Running it on cameras or edge devices turns video into counts and events without storing footage.
Object storage
Storage that keeps data as objects in buckets, each with an address and metadata, rather than as files in folders or rows in tables. It is cheap and scales well, so it is used for archives, exports, images and firmware files.
Observability
How well the inside state of a system can be understood from what it emits: metrics, logs and traces. For an IoT fleet it also means device health data such as uptime, signal and battery, so problems can be found without a site visit.
Occupancy sensor
A sensor that tells whether a space is in use, using infrared, radar, CO₂, sound or camera-based counting. Occupancy data drives lighting and HVAC, and shows how rooms and desks are actually used.
OCPP (Open Charge Point Protocol)
An open protocol between electric vehicle chargers and the back-end systems that manage them: starting and stopping sessions, reporting meter values and status, and setting charging limits. Because it is open, chargers and management systems from different suppliers can work together.
Odour monitoring
Measuring gases such as hydrogen sulphide and ammonia around wastewater works, landfills and farms with electronic sensors. Continuous data links complaints to actual events and to wind direction.
OEE (overall equipment effectiveness)
A measure of how well a machine or line uses its planned time: availability × performance × quality. An OEE of 85 % is usually called world class; many lines run far below it.
In Hermetry Hermetry collects the run, stop and counter signals OEE is built from; the production tracking use case shows how. More about OEE
Offset error
A constant difference between a sensor’s reading and the true value, the same across the range. It is corrected with a single calibration point, unlike gain errors that grow with the reading.
Ohm’s law
The relation between voltage, current and resistance in a conductor: V = I × R. It is the basis for sizing resistors, working out cable losses and turning a 4–20 mA loop current into a voltage at an input.
Oil condition monitoring
Tracking the state of lubricating or insulating oil, through sensors for water content, particles, viscosity or dielectric strength, or by lab samples. Worsening oil warns of wear or leaks in gearboxes, engines and transformers before they fail.
On-premises
Software installed on the customer’s own servers or private cloud rather than used as a hosted service. It is chosen when data must stay on site or the network has no internet.
In Hermetry The same Hermetry platform can be installed on your own servers, with telemetry, dashboards, users and audit logs kept inside your network. More about On-premises
On/off control
The simplest control method: switch the output fully on below the setpoint and fully off above it, usually with a hysteresis band to avoid rapid switching. Thermostats and level controls with pumps often work this way.
OPC DA (OPC Classic)
The older OPC standard for real-time data access between Windows applications, built on the operating system’s component technology. It is still found in many plants, often bridged to OPC UA by a wrapper or gateway.
OPC UA
A platform-independent standard for industrial data exchange, with an information model, built-in security and client-server or publish-subscribe communication. Many modern controllers and machines offer an OPC UA server.
In Hermetry Hermetry Edge, on the gateways Hermetry supports, can read OPC UA servers, depending on the gateway model. More about OPC UA
OPC UA companion specification
A standard information model built on OPC UA for a particular kind of equipment or industry, such as machine tools, robots or pumps. Devices that follow one describe themselves the same way, so software can use them without custom mapping.
OPC UA PubSub
The publish-subscribe part of OPC UA, in which data is sent to subscribers through a broker such as MQTT or directly over UDP, instead of client-server sessions. It suits sending plant data to the cloud and fast machine-to-machine exchange.
Open protocol
A communication protocol whose specification is public and can be implemented by anyone, often without fees. Open protocols such as MQTT, Modbus and BACnet reduce lock-in and let devices from different makers work together.
Open source
Software whose source code is published under a licence that lets others use, study, change and share it. Much IoT infrastructure, from brokers to databases and device libraries, is open source, and its licence terms still have to be followed.
Open window detection
Recognising an open window, from a contact sensor or a sudden temperature drop, so heating or cooling in that room pauses. It saves energy and shows up repeated causes of discomfort.
Open-collector output
An output that switches a connection to ground through a transistor but supplies no voltage of its own, so the receiving side needs a pull-up. Many meters use open-collector pulse outputs.
Open-loop control
Control that sets an output without measuring the result, such as running a pump for a fixed time. It is simple but cannot correct for disturbances, unlike closed-loop control with feedback.
OpenID Connect (OIDC)
An identity layer on top of OAuth 2.0 that lets applications sign users in through an identity provider and learn who they are. It is a common basis for single sign-on to IoT platforms.
In Hermetry Each Hermetry organisation can connect its own SAML 2.0 or OpenID Connect identity provider. More about OpenID Connect
Operating hours counter
A running total of the hours a machine has been on, counted from a run signal or a current threshold. Service intervals for pumps, compressors and engines are often based on it rather than on calendar time.
Optimum start
A building control that works out how early to start heating or cooling so rooms reach their setpoint just as people arrive, using indoor and outdoor temperatures. It saves energy compared with fixed early start times.
Optocoupler (opto-isolator)
A component that passes a signal through light between two electrically separate circuits. Inputs on industrial controllers use optocouplers so faults and noise on field wiring do not reach the electronics.
Orchestration (containers)
Automatically deploying, scaling and restarting software containers across servers. Platforms and edge gateways use orchestration so services recover from failures and can be updated without manual steps.
Orifice plate
A plate with a hole placed in a pipe; the pressure difference across it, measured by a transmitter, gives the flow rate. It is simple and robust and still common in oil, gas and steam measurement.
ORP (oxidation-reduction potential)
A measurement in millivolts of a water’s tendency to oxidise or reduce substances. It is used to monitor disinfection in pools and drinking water and treatment stages in wastewater.
OSI model
A seven-layer reference model of network communication, from the physical layer (cables, radio) up to the application layer. It helps place protocols, for example LoRa at the physical layer and MQTT at the application layer.
OT (operational technology)
The hardware and software that monitor and control physical processes: controllers, SCADA, drives and safety systems. OT puts availability and safety first, which shapes how it is secured.
OT security
Protecting operational technology such as controllers, SCADA and safety systems from cyber attack, where availability and safety come before confidentiality. It relies on segmentation, controlled remote access, inventory and standards such as IEC 62443.
OTA (over-the-air update)
Updating a device’s firmware or settings remotely over its network connection. Safe OTA checks the image’s signature and can roll back if the new version fails to start.
In Hermetry Hermetry sends signed firmware packages to devices, follows each device’s update state and can roll updates out in waves. More about OTA
OTAA (over-the-air activation)
The usual way a LoRaWAN device joins a network: it sends a join request and receives fresh session keys. Keys change with every join, which is safer than ABP.
In Hermetry Hermetry supports OTAA devices and shows where a failing join stops. More about OTAA
OTP (one-time password)
A code valid for a single sign-in or a short time, generated by an app or a security token or sent by message. It is a common second factor in multi-factor authentication.
Out-of-band management
A separate path for managing devices, such as a cellular modem or console line, that works even when the main network is down. It lets a team reach a stuck router or gateway without travelling to site.
Outdoor reset (weather compensation)
Adjusting the heating water temperature to the outdoor temperature: warmer water on cold days, cooler water in mild weather. It keeps rooms comfortable and lets boilers and heat pumps run more efficiently.
Outlier
A reading far from the others, caused by a real event, a sensor fault or a transmission error. Detecting outliers before averaging or alarming keeps single bad values from distorting reports.
Overcurrent protection
Devices such as fuses, circuit breakers and protection relays that disconnect a circuit when current exceeds safe limits. Monitoring their trips and states shows faults and overloads on feeders and motors.
Overflow monitoring
Measuring when and how much a tank, sewer or storm overflow discharges, using level sensors and alarms. Utilities report overflow events to regulators and use the data to plan network upgrades.
See your own devices on Hermetry
Connect a first device, watch its readings live and set an alarm on it. Start free, or ask us to set it up with you.

