IoT glossary: F

IoT and SCADA terms starting with F: Fail-safe, Failover, Fault tolerance, FCU and 34 more, each with a plain definition.

IoT and SCADA terms starting with F include Frequency plan, Firmware signing, Fleet management and FEC. Each of the 38 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.

38 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)

F

Fail-safe

Designed so that a failure leads to a safe state. A valve that closes when it loses power and a control loop that stops when it loses its signal are fail-safe.

Automation and controlRelated: Interlock, Watchdog, SIL

Failover

Switching automatically to a standby component, such as a second server, link or gateway, when the active one fails. Good failover is fast and keeps data, and is tested regularly rather than assumed to work.

OperationsRelated: Redundancy, High availability, Hot standby

Fault tolerance

The ability of a system to keep working, possibly at reduced capacity, when one of its parts fails. It is built with redundancy, failover and designs that avoid a single point of failure.

OperationsRelated: Redundancy, High availability, Failover

FCU (fan coil unit)

A small HVAC unit with a fan and a water coil that heats or cools one room or zone, fed by a central boiler or chiller. Its valve, fan speed and room temperature are typical points read and controlled by a BMS.

BuildingsRelated: HVAC, BMS, Chiller

FDD (fault detection and diagnostics)

Software that analyses building or equipment data against rules and models to find faults, such as a valve leaking by or heating and cooling fighting each other, and suggests their cause. It turns BMS data into a list of things to fix.

BuildingsRelated: BMS, Anomaly detection, Condition monitoring

Feature engineering

Turning raw sensor data into the inputs a model learns from, such as hourly averages, peaks, rates of change or frequency bands. Good features often matter more for predictive maintenance than the choice of model.

Data and analyticsRelated: Predictive maintenance, FFT, Machine learning

FEC (forward error correction)

Adding redundant bits to transmitted data so the receiver can correct some errors itself without asking for a resend. LoRa’s coding rate is a form of FEC: more redundancy makes a link more robust but longer on air.

ConnectivityRelated: Coding rate, Link budget, Time on air

Feeder (electrical)

A circuit that carries power from a substation or main switchboard to a group of loads or a distribution board. Monitoring each feeder’s current, power and breaker state shows where load and faults are on a site or network.

EnergyRelated: Sub-metering, Circuit breaker, Energy meter

FFT (fast Fourier transform)

An algorithm that turns a signal over time into its frequency content. Vibration monitoring uses it to find the frequencies of unbalance, misalignment or bearing faults that a single overall value would hide.

Data and analyticsRelated: Vibration monitoring, Sampling rate, Predictive maintenance

FHSS (frequency-hopping spread spectrum)

A radio technique in which the transmitter switches between many channels in a known pattern during transmission. It makes a link robust against interference on any one channel and is used in several industrial and LPWAN radios.

ConnectivityRelated: ISM band, LBT

A connection that carries data as light through glass or plastic fibre, over long distances and immune to electrical interference and lightning. Plants, substations and campuses use it between buildings and in electrically noisy areas.

ConnectivityRelated: Ethernet, Backhaul, EMC

Field device

An instrument or actuator installed out on the process, such as a transmitter, valve, pump starter or meter, as opposed to controllers and servers in the control room. Field devices are where data starts and where commands finally act.

Automation and controlRelated: Sensor, PLC, Fieldbus

Fieldbus

A family of digital networks that connect sensors, actuators and controllers in a plant, replacing a wire per signal. Modbus, PROFIBUS, CAN and their Ethernet successors are all fieldbuses.

ProtocolsRelated: Modbus RTU, CAN bus, PROFINET

Filter differential pressure

The pressure drop across an air or liquid filter, which rises as the filter clogs. Measuring it lets maintenance change filters when they are actually dirty instead of on a fixed calendar.

BuildingsRelated: AHU, Condition monitoring, Differential pressure

Firewall

A network device or software that allows or blocks traffic according to rules, for example letting devices only make outgoing connections to one platform. Firewalls between office and control networks are a basic part of OT security.

SecurityRelated: Zero trust, Network segmentation, VLAN

Firmware

The software that runs on a device itself. Keeping firmware up to date fixes bugs and security holes, which is why remote updates matter for fleets in the field.

Devices and sensorsRelated: OTA, Firmware signing, FUOTA

Firmware rollback

Returning a device to its previous firmware when a new image fails to start or behaves badly. Devices with two firmware slots can roll back on their own, which makes over-the-air updates far safer.

OperationsRelated: OTA, Firmware, Watchdog

Firmware signing

Attaching a cryptographic signature to a firmware image so a device installs it only if it comes from the maker and has not been changed. It protects fleets from tampered updates.

In Hermetry Hermetry accepts update images with a detached Ed25519 signature or signed for ESP32 Secure Boot V2; unsigned images are only for test devices. More about Firmware signing

SecurityRelated: OTA, PKI, Firmware

Flash memory

Non-volatile memory that holds firmware and stored data in a device and keeps it without power. It is erased in blocks and wears out after a number of write cycles, so data logging firmware spreads writes across it.

Devices and sensorsRelated: EEPROM, Firmware, Store and forward

Fleet management (devices)

Running many devices as one population: their versions, settings, health, certificates and updates. It turns a hundred individual devices into one job.

In Hermetry Every Hermetry device uses one device profile: change the profile, and every device of it follows. More about Fleet management

OperationsRelated: OTA, Provisioning, Heartbeat

Flow computer

A dedicated device that calculates corrected volume, mass or energy of gas or liquid from flow, pressure and temperature readings, following measurement standards. It is used where the flow is sold or taxed, such as pipelines and custody transfer.

EnergyRelated: Custody transfer, Flow meter, Gas volume correction

Flow meter

A meter that measures how much liquid or gas passes through a pipe, as a rate (m³/h) and often as a running total. Common types are electromagnetic, ultrasonic and mechanical.

Devices and sensorsRelated: Totalizer, Pulse counter, DMA

FMEA (failure mode and effects analysis)

A structured review of how each part of a system can fail, what the effect would be and how likely and detectable it is. It is used to decide which failures to monitor, prevent or design out first.

OperationsRelated: Predictive maintenance, RCM, MTBF

Fog computing

Spreading computing and storage between devices and the cloud, on gateways, local servers and network equipment. It is close to edge computing; the term stresses a layered network of such nodes rather than single edge devices.

Data and analyticsRelated: Edge computing, Edge gateway, Hybrid cloud

Forecasting (time series)

Predicting future values of a measurement, such as demand, consumption or a tank level, from its history and related factors like weather or calendar. Forecasts let operators plan pumping, energy purchase and maintenance ahead.

Data and analyticsRelated: Time series, Predictive maintenance, Anomaly detection

FOTA (firmware over the air)

Updating a device’s firmware remotely over its network connection. It is the firmware case of OTA updates; see OTA and FUOTA.

OperationsRelated: OTA, FUOTA

FOUNDATION Fieldbus

A digital fieldbus for process plants in which instruments share one two-wire bus that carries power and data, and can even run control functions in the field. Its H1 variant links instruments; HSE is its Ethernet backbone.

ProtocolsRelated: Fieldbus, HART, PROFIBUS

FPGA (field-programmable gate array)

A chip whose logic can be configured after manufacture, so it can run custom digital circuits in parallel at high speed. It is used in edge devices for fast signal processing, protocol handling and machine vision.

Devices and sensorsRelated: MCU, Edge AI, Embedded system

Frame counter (FCnt)

A number in every LoRaWAN frame that goes up with each message. The network rejects a frame whose counter it has already seen, which stops recorded messages from being replayed.

ConnectivityRelated: LoRaWAN, Session keys, MIC

Frequency converter

Another name for a variable frequency drive (VFD): a device that changes the frequency and voltage fed to a motor to control its speed. See VFD.

Devices and sensorsRelated: VFD

Frequency plan

The set of radio channels, data rates and power limits a LoRaWAN network uses in a region, such as EU868 or US915. Devices, gateways and the network server must all use the same plan.

In Hermetry Hermetry’s network server works with the LoRaWAN regions and frequency plans listed in the docs. More about Frequency plan

ConnectivityRelated: ISM band, LoRaWAN, Duty cycle

Fresnel zone

The football-shaped space around the direct line between two antennas that radio waves need mostly free of obstacles. A link can have clear line of sight and still lose strength if trees or roofs block much of this zone.

ConnectivityRelated: Line of sight, Link budget, Path loss

Frost protection

Measures that keep crops, pipes or equipment from freezing, such as wind machines, sprinklers or heating, triggered when temperature sensors approach 0 °C. Fast, reliable alarms matter because damage can happen within an hour.

AgricultureRelated: Weather station, Threshold, Irrigation controller

FSK (frequency-shift keying)

A simple radio modulation that sends bits by switching between two or more frequencies. Many sub-GHz sensors, older remote controls and the FSK mode of LoRaWAN radios use it.

ConnectivityRelated: LoRa, ISM band, Data rate

FSPL (free-space path loss)

The loss of radio signal strength over distance in open space, with nothing in the way, which grows with both distance and frequency. It is the starting point of every link-budget estimate; real links lose more because of terrain, buildings and foliage.

ConnectivityRelated: Path loss, Link budget, Fresnel zone

Fuel level sensor

A sensor that measures the fuel in a tank, for example with a capacitive probe or float, so fleets and generator sites can track consumption, refills and theft. Sudden drops while a vehicle is parked are a typical theft alarm.

LogisticsRelated: Fleet management, Level sensor, Generator monitoring

Functional safety

The part of overall safety that depends on control systems working correctly, such as an emergency shutdown acting when needed. Standards like IEC 61508 and IEC 61511 set how such systems are specified, built and tested.

StandardsRelated: SIL, IEC 61508, SIS

FUOTA (firmware update over the air)

Sending new firmware to devices by radio, in LoRaWAN usually by multicast in many small fragments. It is slow on low-power networks, so images are kept small and sent in planned windows.

OperationsRelated: OTA, Firmware, Multicast