New: the AI firewall watches the whole platform and explains each incident in plain words. See how it works

IoT glossary: N

IoT and SCADA terms starting with N: N+1 redundancy, Nameplate data, NAT, NB-IoT and 32 more, each with a plain definition.

IoT and SCADA terms starting with N include NB-IoT, NFC, Network server and NTP. Each of the 36 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.

36 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)

N

N+1 redundancy

Having one more unit than needed, such as five pumps where four carry the load, so one can fail or be serviced without loss. The same idea applies to servers, power supplies and gateways.

OperationsRelated: Redundancy, High availability, Availability

Nameplate data

The ratings printed on a motor, pump, transformer or meter: rated power, voltage, current, speed, serial number. Recording them with the device gives monitoring its limits, such as the current at which a motor is overloaded.

Devices and sensorsRelated: Metadata, Digital twin, Condition monitoring

NAT (network address translation)

A router function that lets many devices with private addresses share one public address. It also means devices behind NAT cannot be reached from outside, which is why IoT devices open the connection outwards to the platform.

ConnectivityRelated: VPN, Remote access, Private network

NB-IoT (Narrowband IoT)

A cellular technology for IoT that uses a narrow 200 kHz band, giving deep indoor and underground coverage and long battery life. It suits fixed devices that send little data, such as meters.

In Hermetry Gateways and devices with NB-IoT connectivity are listed in Hermetry’s device catalogue. More about NB-IoT

ConnectivityRelated: LTE-M, Cellular IoT, PSM

Net metering

A billing arrangement in which electricity a customer exports from solar panels offsets what they import, measured by a meter that counts both directions. Monitoring import and export separately shows how much self-generated power is used on site.

EnergyRelated: PV (photovoltaic) system, Smart meter

Network segmentation

Splitting a network into separate zones with controlled traffic between them, for example keeping controllers apart from office PCs. In OT security it limits how far an attacker or a fault can spread.

SecurityRelated: VLAN, Purdue model, Zone

Network server (LNS)

The server at the centre of a LoRaWAN network. It removes duplicate frames heard by several gateways, checks and decrypts them, manages data rates and sends downlinks through the best gateway.

In Hermetry Hermetry includes its own LoRaWAN network server; each organisation has its own server address. More about Network server

ConnectivityRelated: LoRaWAN, LoRaWAN gateway, ADR

Network slicing

A 5G feature that runs several virtual networks with different performance guarantees on the same physical network. A slice can, for example, give a utility’s devices reserved capacity and low latency apart from public traffic.

ConnectivityRelated: Private network, RedCap, Latency

Network topology

The way the nodes of a network are arranged and connected: star, bus, ring, tree or mesh. Topology decides how far a failure spreads and how messages travel, for example star for LoRaWAN and mesh for many building radios.

ConnectivityRelated: Mesh network, Star topology, Fieldbus

Neural network

A machine-learning model made of layers of simple connected units that learn weights from examples. Small neural networks can run on edge devices to recognise sounds, images or vibration patterns without sending raw data to the cloud.

Data and analyticsRelated: Machine learning, TinyML, Edge computing

NFC (near-field communication)

A very short-range radio, a few centimetres, used to tap a phone against a device to read it or set it up. Many sensors use NFC for commissioning.

ConnectivityRelated: Provisioning, BLE

Night flow (minimum night flow)

The lowest flow into a water area at night, typically between 2 and 4 a.m., when almost no one uses water. Most of it is leakage, so a rising night flow is the classic sign of a new leak.

In Hermetry The water network use case shows minimum night flow per DMA watched in Hermetry. More about Night flow

WaterRelated: DMA, Leak detection, NRW

Night setback

Lowering heating setpoints, or raising cooling ones, outside occupied hours to save energy. Monitoring checks that setback really happens and that rooms recover in time before people arrive.

BuildingsRelated: Setpoint, BMS, HVAC

NIS2 Directive

The European Union directive on the security of network and information systems, replacing the first NIS Directive. It covers many essential and important sectors, including energy, water and manufacturing, and requires risk management, incident reporting and supply-chain security.

StandardsRelated: IEC 62443, Audit log, Zero trust

NIST Cybersecurity Framework

A widely used framework from the US National Institute of Standards and Technology that organises security work into functions such as govern, identify, protect, detect, respond and recover. Organisations use it to structure and compare their security programmes, including for OT.

StandardsRelated: IEC 62443, NIS2 Directive, OT security

NMEA 0183

A simple serial text format, standardised by the marine electronics association, in which GNSS receivers and marine instruments send sentences such as position and speed. Many GPS modules in trackers still output NMEA 0183 sentences.

ProtocolsRelated: GNSS, UART, NMEA 2000

NMEA 2000

A CAN-based network standard for connecting marine instruments, engines and displays on a vessel. Gateways read it to bring boat and engine data into remote monitoring.

ProtocolsRelated: CAN bus, NMEA 0183, J1939

NO₂ (nitrogen dioxide) monitoring

Measuring nitrogen dioxide in outdoor air, mainly from road traffic and combustion. Low-cost sensor networks map street-level pollution between official reference stations, provided they are calibrated and corrected for temperature and humidity.

Smart cityRelated: PM2.5 and PM10, Air quality sensor, Calibration

Node

Any device on a network that sends, receives or forwards data: a sensor, a gateway, a router or a server. In LoRaWAN and mesh networks the word often means an end device.

ConnectivityRelated: Gateway, Mesh network, End device

Noise floor

The level of background radio noise at a receiver, below which signals cannot be told apart from noise. A raised noise floor from nearby equipment shrinks range even when the signal itself has not changed.

ConnectivityRelated: SNR, RSSI, Link budget

Noise monitoring

Measuring sound levels with sensors, usually as A-weighted decibels averaged over set periods. Cities, construction sites and venues use it to check limits at night and to answer complaints with data.

Smart cityRelated: Sensor, Threshold

Nominal capacity (battery)

The capacity a battery is rated for, in mAh or Ah, under the manufacturer’s test conditions. Real devices see less because of cold, high pulse currents and self-discharge, so battery-life estimates should include a margin.

Devices and sensorsRelated: Battery life, Primary cell

Non-repudiation

Assurance that someone cannot later deny an action they took, such as sending a command or approving a change. It rests on strong authentication, digital signatures and tamper-evident audit logs.

SecurityRelated: Audit log, Digital signature, PKI

Non-volatile memory

Memory that keeps its contents without power, such as flash or EEPROM. Devices store settings, keys, counters and buffered readings there so they survive resets and battery changes; it has a limited number of write cycles.

Devices and sensorsRelated: Firmware, Store and forward, MCU

Nonce

A number used only once in a security protocol, so that an old message cannot be replayed as if new. LoRaWAN join requests, for example, carry a device nonce that the network checks has not been seen before.

SecurityRelated: Join procedure, Frame counter

Normally open / normally closed (NO/NC)

Whether a contact is open or closed when it is at rest. Alarm circuits are often normally closed, so a broken wire looks like an alarm instead of looking like calm.

Automation and controlRelated: Dry contact, Relay, Fail-safe

Northbound interface

The interface a system offers upwards to higher-level applications, such as a platform’s REST API, webhooks or data export. The southbound side faces the devices and field networks.

Data and analyticsRelated: REST API, Webhook

Notification

A message that tells a person something happened, sent by e-mail, SMS, push, chat or voice. Good notifications go to the right person, say what to do and are not sent so often that people learn to ignore them.

In Hermetry Hermetry offers each notification to its recipients on every channel that applies: in-app, e-mail, SMS, push and chat apps, with quiet hours. More about Notification

OperationsRelated: Alarm, Push notification, Escalation

NR (New Radio)

The radio interface of 5G as defined by 3GPP. NR covers everything from high-speed broadband to reduced-capability devices for IoT, and it is used in public and private 5G networks.

ConnectivityRelated: RedCap, Cellular IoT, Network slicing

NRW (non-revenue water)

Water that is put into a network but never billed: leaks, theft, meter errors and unbilled use. It is the main loss figure of a water utility.

WaterRelated: Night flow, DMA, Leak detection

NTC thermistor

A temperature-sensing resistor whose resistance falls as temperature rises. It is cheap and sensitive, so it appears in many sensors and appliances, but it needs a curve or table to convert resistance to degrees.

Devices and sensorsRelated: Pt100, Analog input

NTN (non-terrestrial network)

A cellular network that uses satellites or high-altitude platforms instead of, or alongside, ground towers, as specified by 3GPP for NB-IoT and NR. It extends IoT coverage to seas, deserts and remote pipelines.

ConnectivityRelated: Satellite IoT, NB-IoT, NR

NTP (Network Time Protocol)

A protocol that sets device clocks from time servers over the network. Accurate clocks matter because every reading and event is time-stamped.

In Hermetry When readings drift a little more every day, Hermetry’s troubleshooting guide points to the device clock: use NTP, or leave the timestamp out. More about NTP

Data and analyticsRelated: Timestamp, GNSS

Nuisance alarm

An alarm that fires often without needing any action, for example from a noisy reading near its threshold. Nuisance alarms train operators to ignore alarms and are a main target of alarm management.

Automation and controlRelated: Alarm flood, Deadband, ISA-18.2

NVR (network video recorder)

A device that records video streams from IP cameras on the network and serves them for playback. Monitoring its disks, recording state and camera connections catches gaps before footage is needed.

In Hermetry Hermetry adds a network video recorder’s channels from the Devices page and tests the connection before it stores anything. More about NVR

Devices and sensorsRelated: IP camera, Heartbeat

NwkSKey (network session key)

The LoRaWAN session key used by the network server to check message integrity and handle MAC commands. It is one of the session keys created at join (or set by hand with ABP); see session keys.

SecurityRelated: Session keys, MIC

See your own devices on Hermetry