IoT and SCADA terms starting with V include VPN, V2G, VAV and VFD. Each of the 20 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.
Showing 0 terms on V · Clear
20 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)
V
V2G (vehicle-to-grid)
Letting electric vehicles not only charge from the grid but also send energy back when the grid needs it. It needs bidirectional chargers and communication between charger, vehicle and grid operator.
Valve actuator
The motor, pneumatic or hydraulic unit that opens and closes a valve on command. Remote actuators report position, torque and faults, so an operator can confirm that a valve actually moved, not just that the command was sent.
VAV (variable air volume)
An HVAC system, and the box in each zone, that controls temperature by varying how much conditioned air flows into a room. VAV systems save fan energy compared with constant-volume systems, because air flow follows the actual demand of each zone.
Vector database
A database that stores items as lists of numbers that capture their meaning, so it can find the most similar items quickly. AI assistants use it to look up relevant documents, manuals or past incidents before answering a question.
Vendor lock-in
Depending on one supplier so heavily that switching becomes difficult or expensive, for example because data cannot be exported or devices only talk to one platform. Open protocols, data export and standard formats reduce it.
Vertical farming
Growing crops in stacked layers indoors under artificial light, with closely controlled climate, water and nutrients. It depends heavily on sensors and automation for temperature, humidity, CO₂, light and nutrient solution.
VFD (variable frequency drive)
An electronic drive that controls a motor’s speed by changing the frequency of its supply. Slowing pumps and fans with a VFD saves a large share of their energy.
Vibration monitoring
Measuring how a machine shakes, as velocity, acceleration and frequency content. Rising vibration is often the first sign of imbalance, misalignment or bearing wear.
Vibration velocity
The speed of a machine surface’s vibration, usually given as an RMS value in mm/s. ISO 20816 groups velocity levels into zones from good to unacceptable for different machine classes, which makes it the most common figure for judging machine health.
Video analytics
Software that analyses camera images automatically, for example to count vehicles, detect intruders or check that people wear protective equipment. Running it at the edge means only events and snapshots need to be sent, not continuous video.
Virtual sensor (computed value)
A value calculated from other readings instead of measured, such as power from current and voltage or efficiency from flow and energy. It adds a value without adding hardware, as long as the readings it is built from are trustworthy.
VLAN (virtual LAN)
A way to split one physical network into separate logical networks, for example to keep control devices apart from office computers. VLANs are a basic step in network segmentation for control systems.
VOC (volatile organic compounds)
Carbon-based chemicals that evaporate easily at room temperature, released by paints, cleaning products, furniture and people. Indoor air quality sensors often report a total VOC index alongside CO₂ and particles.
Voltage divider
Two resistors in series that produce an output voltage that is a fixed fraction of the input. It is used to scale a voltage down to what an analogue input can read, for example to measure a 24 V battery with a 3.3 V converter.
Voltage regulator
A circuit that keeps a steady output voltage from a varying input, such as 3.3 V from a battery that falls from 4.2 V to 3.0 V. On battery devices, a regulator with very low quiescent current is essential for long life.
Voltage sag (dip)
A short drop in supply voltage, typically lasting from half a cycle to a few seconds, often caused by a fault elsewhere on the network or a large motor starting. Sags can stop production lines and reset controllers, so power quality monitors record them.
VPD (vapour pressure deficit)
The difference between how much moisture air could hold at its temperature and how much it actually holds, in kPa. It drives how fast plants transpire; growers in greenhouses often aim for roughly 0.8–1.2 kPa during growth and adjust ventilation, heating and misting to keep it there.
VPN (virtual private network)
An encrypted tunnel that joins a device or a network to another network across the internet. A classic VPN gives access to a whole network, so it is limited to the people and devices that need it.
VPP (virtual power plant)
Many small energy resources, such as batteries, solar inverters, heat pumps and backup generators, controlled together so they act like one power plant. Their combined flexibility is offered to grid operators and energy markets.
Vulnerability management
The ongoing work of finding, ranking and fixing security weaknesses in devices and software, from tracking published vulnerabilities and severity scores to rolling out patches. For IoT fleets it depends on knowing every device’s firmware version and being able to update it remotely.