IoT and SCADA terms starting with R include RS-485, REST API, RFID and RPC. Each of the 53 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.
Showing 0 terms on R · Clear
53 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)
R
Radar level sensor
A sensor that measures the level of a liquid or bulk solid by timing a microwave signal reflected from the surface. It does not touch the medium and is barely affected by vapour, dust or temperature, which makes it common on tanks, silos and open channels.
Radio channel
A slice of a frequency band that one transmission uses. Devices spread their messages over several channels so that one busy or noisy channel does not block them.
Rain gauge
An instrument that measures rainfall. The common tipping-bucket type sends a pulse each time a small bucket fills, often for every 0.2 mm of rain, so a pulse counter can record both totals and intensity.
Ramp rate
How fast a value is allowed to change, such as a heating set point rising 2 °C per minute or a generator increasing output in kW per second. Ramp limits protect equipment and processes from sudden changes.
Rate limiting
Capping how many requests or messages a client may send in a period, and rejecting or delaying the rest. It protects a service from overload and from a single faulty or hostile client, and devices should be written to back off when they hit a limit.
In Hermetry Hermetry’s REST API answers 429 when a rate limit is reached, and the docs list each limit and how to retry safely. More about Rate limiting
Rate-of-change alarm
An alarm that fires when a value rises or falls faster than expected, rather than when it crosses a fixed limit. A tank level dropping 10 cm a minute may still be well within range but already signals a burst or an open valve.
RBAC (role-based access control)
Giving rights by role rather than person by person: an operator may acknowledge alarms, an engineer may change rules, an admin may add users. It keeps rights consistent as people join, move and leave, because only the role assignment changes.
In Hermetry A Hermetry member’s rights come from their role, their groups and access policies, with ready IoT operator and IoT viewer templates. More about RBAC
RCD (residual current device)
A safety switch that cuts power when the current going out on the live conductor differs from the current coming back, a sign that it is leaking to earth, possibly through a person. Devices for personal protection usually trip at 30 mA. Monitoring can report trips at remote sites.
RCM (reliability-centred maintenance)
A structured method for deciding how each asset should be maintained, based on how it can fail and what the failure would cost. It chooses between condition-based, time-based and run-to-failure approaches item by item, instead of servicing everything on the same schedule.
Reactive power
Power that moves back and forth between the supply and inductive or capacitive loads, such as motors, without doing useful work, measured in kvar. It loads cables and transformers, and many utilities charge for it, which is why sites correct their power factor.
Real time
In monitoring, data that arrives within seconds; in control, a guaranteed response within a fixed deadline. The two meanings differ by several orders of magnitude.
Receiver sensitivity
The weakest signal a receiver can still decode reliably, in dBm. The lower the number the better: LoRa at its slowest settings can decode signals near −137 dBm, which is why it reaches so far. Sensitivity is one side of every link budget.
Recipe (batch control)
A set of parameters and steps for making a product, such as temperatures, times and quantities, that a control system loads before a batch starts. ISA-88 describes how recipes are structured. Recording which recipe each batch used is part of traceability.
Recloser
A circuit breaker on overhead power lines that opens on a fault and then closes again automatically a few times, because most faults, such as a branch touching a line, clear on their own. Remote monitoring shows its state, counts operations and reports lockouts.
RedCap (5G reduced capability)
A lighter class of 5G devices with less bandwidth, fewer antennas and lower power than full 5G, for wearables, industrial sensors and gateways that need more than LTE-M. It suits devices that need moderate data rates and the low latency of 5G networks, without the cost and power of a smartphone modem.
Redundancy
Having a second unit, link or path ready to take over when the first fails, such as two network links on a gateway or two power supplies. It raises availability, but only if the switch-over itself is tested and the second unit does not share the first one’s weak point.
Reefer container
A refrigerated shipping container with its own cooling unit. Remote reefer monitoring reports set point, supply and return air temperature, door state and alarms during the journey, so a failing unit can be dealt with before the cargo spoils.
Refrigeration monitoring
Continuous measurement of cold rooms, freezers and display cases, usually air temperature plus door contacts, defrost state and compressor status. It catches failing equipment and doors left open early, and produces the temperature records food and pharma rules require.
Regional parameters (LoRaWAN)
The part of the LoRaWAN specifications that sets, for each region, the frequency plan, channels, data rates, maximum payloads, transmit power and duty-cycle rules, for example EU863-870 or US902-928. A device and its network must use the same regional settings.
Relative humidity (RH)
How much water vapour air holds compared with the most it could hold at that temperature, in percent. Because warm air holds more, the same air shows a lower RH when heated, so humidity readings are almost always paired with temperature.
Relay
An electrically operated switch: a small control signal opens or closes a separate circuit, such as a pump contactor. Relays also give galvanic separation, so a low-voltage controller can switch mains-powered equipment safely.
Remote access
Reaching a device or a local network from afar, for example to open a controller’s web panel or change a PLC program, without driving to the site. It saves time and travel, but it is also a way in for attackers, so it needs strong sign-in, narrow rights and a record of every session.
In Hermetry Hermetry opens the web panel of a claimed router through a tunnel the router dials out to, so the router needs no fixed IP address and no open ports. More about Remote access
Remote I/O
Input and output modules placed near the equipment they connect to and linked back to a controller or gateway by a network, instead of running every signal cable to a central panel. It cuts wiring and makes it easy to add points at distant sites.
Repeater
A device that receives a radio signal and sends it out again to extend its reach, or that regenerates a signal on a long wired bus. In mesh networks many devices act as repeaters for each other; in star networks such as LoRaWAN, extra gateways are used instead.
Report by exception
Sending a value only when it changes by more than a deadband, or when a status changes, instead of at fixed intervals. It saves bandwidth and battery.
Resolution (measurement)
The smallest change a sensor or converter can show, such as 0.1 °C. Resolution is not accuracy: a reading can change in steps of 0.01 °C and still be 0.5 °C away from the true value.
REST API
A web API built around resources at addresses, read and changed with HTTP methods such as GET, POST and DELETE, usually with JSON bodies. Most IoT platforms offer one so that other systems can read data and manage devices.
In Hermetry Every Hermetry management path is scoped to your organisation and called with an API key as a bearer token. More about REST API
Retrofit
Adding sensors, meters or connectivity to existing equipment, such as clamp-on current sensors on an old motor. It brings old equipment into monitoring without replacing it, often in hours rather than months.
Retry policy
The rules a device or service follows when a request fails: how many times to try again and how long to wait in between. Good policies wait longer after each failure and add some randomness, so thousands of devices do not all reconnect in the same second after an outage.
Reverse osmosis (RO)
A water treatment process that pushes water through a membrane fine enough to hold back salts and most contaminants. Monitoring feed pressure, differential pressure, conductivity and flow shows membrane fouling early and tells operators when to clean.
RFID (radio-frequency identification)
Identifying tags by radio, usually without a battery in the tag: the reader powers it and reads its identifier. Common bands are 13.56 MHz for short range and 860–960 MHz (UHF) for reading at a few metres. It is used for inventory, access control and tracking returnable assets.
Ring topology
A network in which devices are connected in a closed loop. Industrial Ethernet rings can recover from one broken cable within milliseconds by sending traffic the other way round, which makes them popular in plants and substations.
Risk assessment (cyber security)
Identifying what could go wrong in a system, how likely it is and how bad the result would be, then choosing measures in proportion. IEC 62443 describes it for industrial systems, dividing a site into zones and conduits with a target security level for each.
Roaming
Using another operator’s network outside your own coverage. Cellular devices roam between mobile networks; LoRaWAN devices can roam when network servers exchange traffic over agreed back-end interfaces. Some countries restrict devices that roam permanently.
Rolling update
Updating a fleet or a server cluster a few members at a time instead of all at once, checking each batch before moving on. If something goes wrong, only part of the fleet is affected and the update can be stopped.
Rollup (aggregate)
A summary of readings over a period, such as the hourly average, minimum, maximum or total. Rollups make long charts and reports fast.
In Hermetry Hermetry summarises numeric readings per minute, hour and day and reads the summary that fits a chart’s time window. More about Rollup
Root cause analysis (RCA)
Working back from a failure to the underlying reason it happened, rather than the first symptom seen. Time-stamped readings, alarm histories and sequence-of-events records from monitoring are the raw material for most root cause analyses.
Root of trust
The small, highly protected part of a device that everything else relies on for security, such as an immutable boot loader or a secure element holding the device key. If the root of trust is sound, the device can prove its identity and verify its own firmware.
Router
A device that forwards traffic between networks, for example between a site’s local network and a cellular or fibre connection. Industrial routers add serial ports, digital inputs, VPN and firewall functions, and often act as the site’s IoT gateway as well.
RPC (remote procedure call)
Calling a function on another system as if it were local. Device platforms use RPC for commands that expect an answer, such as "read the current setting".
In Hermetry In Hermetry a command, also called RPC, asks a device to do something, such as reboot or switch an output, and is followed until it ends. More about RPC
RPO and RTO (recovery point and recovery time objectives)
Two targets for recovering from a failure. The recovery point objective is how much recent data you can afford to lose, such as five minutes; the recovery time objective is how long the service may be down. Together they decide how backups and replicas are designed.
RS-232
An old point-to-point serial interface for short cables, still found on instruments, modems and older equipment. It links two devices only and over short distances, usually up to about 15 metres.
RS-422
A serial standard that sends each signal as a voltage difference on a pair of wires, for long cable runs with little noise. Unlike RS-485 it has one transmitter per pair, so it is used for point-to-point links and full-duplex connections rather than shared buses.
RS-485
A serial interface on a two-wire twisted pair that links many devices on one bus over up to about 1,200 metres. Modbus RTU and BACnet MS/TP run on it.
In Hermetry Gateways with RS-485 ports are listed in Hermetry’s device catalogue. More about RS-485
RSSI (received signal strength indicator)
How strong a received radio signal is, usually in dBm. Values nearer zero are stronger; in LoRa, signals far below the noise can still be decoded, which is why SNR matters too.
RTC (real-time clock)
A small clock chip, often with its own backup battery, that keeps date and time while the rest of a device is off. Devices that log data offline need a reliable RTC so their readings carry the right timestamps when they are finally sent.
RTD (resistance temperature detector)
A temperature sensor whose resistance rises predictably with temperature, usually made of platinum. A Pt100 reads 100 Ω at 0 °C and changes by about 0.385 Ω per °C. RTDs are more accurate and stable than thermocouples but cover a narrower range.
RTSP (Real Time Streaming Protocol)
A protocol for controlling live video streams from IP cameras and recorders, with commands to start, pause and stop a stream. It usually runs on port 554 and carries the video itself over RTP. Most monitoring software that shows camera images speaks RTSP.
RTU (remote terminal unit)
A rugged field device at a remote site that collects data from sensors and equipment and talks to a control centre, often over telemetry protocols such as DNP3. RTUs are built for harsh, unmanned sites and usually have their own power backup and local logic.
RUL (remaining useful life)
An estimate of how long an asset can keep working before it needs repair or replacement, based on its condition data and how similar assets aged. RUL turns monitoring into a planning figure, such as a bearing likely to last another six weeks.
Rules engine
The part of a platform that evaluates conditions on incoming data and runs actions when they are met: raising alarms, sending notifications, writing values or calling other systems. Rules let a platform react to data at once and in the same way every time, without a person watching the screens.
In Hermetry You write Hermetry rules in sentences in the Rules card on a dashboard; each rule runs as a flow behind the scenes. More about Rules engine
Run hours
The total time a machine has actually been running, counted from a running signal or current reading. Many maintenance schedules are based on run hours rather than calendar time, such as an oil change every 2,000 hours.
RX window (LoRaWAN receive window)
A short time after each uplink during which a LoRaWAN class A device listens for a reply. By default the first window opens one second after the uplink and the second window a second later. Outside these windows a sleeping class A device cannot be reached.