IoT and SCADA terms starting with H include HMI, HVAC, HTTP and HMAC. Each of the 32 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.
Showing 0 terms on H · Clear
32 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)
H
Half-duplex
A link on which both sides can transmit, but not at the same time, such as two-wire RS-485 or most radios. Protocols on half-duplex links take turns, for example a Modbus master that asks and then waits for the answer.
Hall-effect sensor
A sensor that measures a magnetic field, used to detect position, speed and proximity, or to measure current without touching the conductor. It is common in flow meters, wheel speed sensors and clamp-on current sensors.
Harmonics
Currents and voltages at multiples of the grid frequency, caused by non-linear loads such as drives, chargers and LED drivers. They heat transformers and cables and disturb other equipment; THD sums them up.
HART
A protocol that sends digital data on top of a 4–20 mA current loop, so a field instrument can report diagnostics and extra values over the same two wires as its analog signal. Existing loop wiring and analog inputs keep working, while a handheld or a HART-capable input can read the extra data.
Hash function
A function that turns any input into a fixed-length fingerprint, such that a tiny change gives a completely different result. Cryptographic hashes such as SHA-256 are used to check firmware integrity, store passwords and build signatures.
Hazardous area (Ex zone)
A place where flammable gas, vapour or dust may be present, classified into zones by how often and how long it is there. Equipment used there must be certified for that zone and gas group, for example as intrinsically safe or flameproof.
Head (pump)
The height to which a pump can lift water, or the pressure it adds expressed as metres of water column. A pump’s duty point is where its head-flow curve meets the system curve of the network.
Health check
A regular automatic test that a service, device or connection is working, such as an endpoint that answers when all is well. Monitoring systems poll health checks and raise alarms or restart components when they fail.
Heartbeat (offline detection)
A regular message, or simply the regular arrival of data, that shows a device is alive. When it stops for longer than expected, the device is treated as offline.
In Hermetry A Device offline rule on the device profile raises an alarm when a device stops talking. More about Heartbeat
Heat index
A measure of how hot it feels to people when relative humidity is combined with air temperature. It is used for worker safety and comfort alarms, since high humidity stops the body cooling through sweat.
Heat meter
A meter that measures thermal energy delivered by hot or chilled water, from the flow and the temperature difference between supply and return. It is used for billing in district heating and for sub-metering in buildings.
Heat pump
A machine that moves heat from a colder place to a warmer one using a refrigeration cycle, for heating or cooling buildings and water. Its efficiency is given as COP; monitoring shows whether it runs as efficiently as designed.
Hermetry
Hermetry is a secure industrial IoT and SCADA platform, made with love by Roltek. It connects your devices, shows them live on dashboards and SCADA screens, and acts before small problems grow.
In Hermetry See what it does on the platform overview, or try it with your own devices.
Hierarchy (asset)
The tree that organises assets from the enterprise down to sites, areas, lines, machines and parts. Data and alarms rolled up along the hierarchy let people see a whole site or drill down to one pump.
High availability
Designing a system so it keeps running when a part fails, usually by running parts in duplicate with automatic switch-over. It is measured as the share of time the service is up.
High-performance HMI
A style of operator screen that uses greys and muted colours, saving bright colour for abnormal states, and shows trends and context instead of pictures of equipment. It helps operators spot problems faster; ISA-101 describes it.
Histogram
A chart that shows how often values fall into each range, such as how many hours a temperature spent in each band. It reveals spread and outliers that an average hides.
In Hermetry Hermetry’s chart cards include a histogram, next to line, bar, area, pie, scatter and heatmap charts. More about Histogram
Historian
A database built to store process values over time at high rates and to return them quickly for trends and reports. It is the long-term memory of a SCADA system.
In Hermetry To keep every reading in a historian of your own, a Hermetry flow can forward it after saving, by HTTP request, MQTT out or webhook. More about Historian
HMAC (hash-based message authentication code)
A short code computed from a message and a shared secret with a hash function, which proves that the message came from someone with the secret and was not changed. Webhooks are often signed with HMAC-SHA256.
In Hermetry Hermetry signs every webhook with HMAC-SHA256 of the timestamp and body, using your secret. More about HMAC
HMI (human-machine interface)
The screen through which operators see and control a machine or process: process drawings, values, alarms and buttons. A SCADA system shows HMI screens for a whole site or for many sites.
In Hermetry Hermetry draws process screens in the browser from a library of animated SCADA symbols. More about HMI
Home automation
Control of lighting, heating, blinds, locks and appliances in a home from apps, schedules and sensors. It uses short-range radios such as Zigbee, Z-Wave, Thread and Wi-Fi, increasingly tied together by the Matter standard.
Horizontal scaling
Handling more load by adding more machines rather than making one machine bigger. IoT back ends scale horizontally so that the number of devices and messages can grow without a ceiling.
Hot standby
A redundant component that runs alongside the active one, with its data kept in step, so it can take over almost instantly. Redundant PLCs, servers and SCADA nodes are often run in hot standby.
HSM (hardware security module)
A tamper-resistant device that stores cryptographic keys and performs operations with them, so private keys never leave it. Certificate authorities and key servers use HSMs to protect the keys that sign device certificates and firmware.
HTTP (Hypertext Transfer Protocol)
The request and response protocol of the web. Devices that wake up, send and sleep often use HTTPS POST requests, because they need no permanent connection.
In Hermetry Devices that wake up, send and sleep can use Hermetry’s HTTPS device API, handled exactly like MQTT messages. More about HTTP
HTTPS
HTTP carried over TLS, so the connection is encrypted and the server proves its identity with a certificate. Devices and APIs should only use HTTPS on public networks.
In Hermetry Devices that cannot keep an MQTT connection can send over Hermetry’s HTTPS device API, with the same payloads and limits as MQTT. More about HTTPS
Humidity sensor
A sensor that measures the moisture in air, usually as relative humidity in percent, often combined with temperature. It matters for comfort, mould prevention, storage of goods and many industrial processes.
HVAC (heating, ventilation and air conditioning)
The systems that keep a building’s temperature, humidity and air quality right. They are usually the largest energy user in a building.
In Hermetry The building HVAC and energy use case brings air handling units, chillers, boilers and heat pumps into Hermetry with the meters that serve them. More about HVAC
Hybrid cloud
An arrangement that combines on-premises or private infrastructure with public cloud services, with data and workloads moving between them. In IoT it often means local edge or plant servers for control and a cloud platform for fleet-wide analysis.
Hydraulic model
A computer model of a pipe network that calculates flows and pressures from the pipes, pumps, valves and demands. Calibrated with live meter and pressure data, it helps plan works, find leaks and test what-if changes.
Hydrostatic level sensor
A submersible pressure sensor that measures liquid level from the weight of the liquid above it. It is simple and reliable for wells, tanks and channels, but needs the liquid density and, for sealed versions, compensation for air pressure.
Hysteresis (alarm deadband)
A gap between the value that raises an alarm and the value that clears it, such as on at 80 °C and off at 75 °C. It stops a reading hovering at the limit from switching the alarm on and off.
In Hermetry Hermetry alarm rules have a hysteresis (clear margin) setting. More about Hysteresis
See your own devices on Hermetry
Connect a first device, watch its readings live and set an alarm on it. Start free, or ask us to set it up with you.