M

M-Bus (Meter-Bus)

A European standard (EN 13757) for reading utility meters, such as water, heat, gas and electricity, over a two-wire bus. Wireless M-Bus is its radio variant, used for walk-by and fixed-network meter reading.

ProtocolsRelated: Smart meter, Energy meter, Modbus RTU

M2M (machine-to-machine)

Communication between devices without a person in the loop, such as a meter reporting to a utility or a pump controller talking to a tank sensor. The term is older than IoT and is still used by mobile operators for device SIM plans and networks.

ConnectivityRelated: IoT, Cellular IoT, Telemetry

MAC address

A hardware address, usually 48 bits written as six pairs of hex digits, that identifies a network interface on Ethernet, Wi-Fi or Bluetooth. It is used to deliver frames on the local network and is often printed on device labels for provisioning.

ConnectivityRelated: Ethernet, Wi-Fi, EUI-64

MAC command (LoRaWAN)

A control message between a LoRaWAN device and the network server, carried inside normal frames. MAC commands set data rates and power, add channels and check the link, without involving the application.

ConnectivityRelated: ADR, LoRaWAN, Network server

Machine learning

Building models that learn patterns from data instead of following hand-written rules. In IoT it is used to spot anomalies, forecast consumption or failures and classify events from sensor readings, and it needs clean, well-labelled history to work.

Data and analyticsRelated: Anomaly detection, Predictive maintenance, Time series

Machine vision

Using cameras and image processing to inspect, measure or count things automatically, for example checking labels, reading codes or finding defects on a line. Results are usually passed to the line controller or MES as pass/fail signals and counts.

ManufacturingRelated: Object detection, MES, Edge computing

Magnetic flow meter (magmeter)

A flow meter that measures the voltage induced when a conductive liquid moves through a magnetic field. It has no moving parts and no pressure loss, which makes it common for water, wastewater and slurries; it cannot measure non-conductive liquids such as oils.

WaterRelated: Flow meter, Totalizer, Pressure transmitter

Magnetometer

A sensor that measures magnetic field strength and direction. In IoT it serves as an electronic compass, detects vehicles above parking bays and senses whether a door or lid is open when paired with a magnet.

Devices and sensorsRelated: Parking sensor, Accelerometer

Mains power monitoring

Watching whether a site or cabinet still has mains power, often with voltage and frequency readings. A device on battery or UPS can report the loss at once, which separates a power cut from a communications fault.

EnergyRelated: UPS, Heartbeat, Power quality

Maintenance window

An agreed period in which updates, restarts or repairs may interrupt a service. Scheduling firmware updates and server work inside such windows keeps unexpected downtime away from operating hours.

OperationsRelated: OTA, Availability, Patch management

Man-in-the-middle attack

An attack in which someone secretly sits between two parties, reading or altering their messages while each believes it talks to the other. Mutual authentication and properly checked certificates are the main defence, which is why devices must not skip certificate validation.

SecurityRelated: mTLS, TLS, X.509 certificate

Mass flow meter (Coriolis)

A flow meter that measures mass flow directly from the twisting of vibrating tubes as fluid passes through them. It is accurate for liquids and gases regardless of density and also reports density and temperature, so it is used for custody transfer and dosing.

Devices and sensorsRelated: Flow meter, Magnetic flow meter, Totalizer

Matter

An open application standard for smart home devices that runs over Wi-Fi, Ethernet and Thread, so devices from different makers work with the same controllers. Devices are set up with a QR code and controlled locally, without needing a particular cloud service.

ConnectivityRelated: Thread, Zigbee, Wi-Fi

Maximum demand

The highest average power drawn over a billing interval, typically 15 or 30 minutes, within a month or year. Many tariffs charge for it separately, so a short peak can cost as much as days of normal use.

EnergyRelated: Demand charge, Peak demand, Load profile

MCP (Model Context Protocol)

An open protocol through which AI assistants connect to tools and data. A system offers MCP servers that describe what an assistant may read or do, and the assistant calls them on the user’s behalf.

In Hermetry Hermetry offers MCP servers; an assistant acts as the person who connected it and never gets more rights than that person or API key. More about MCP

ProtocolsRelated: API, API key, REST API

MCSA (motor current signature analysis)

Finding motor and load faults by analysing the frequency content of the motor’s supply current. Broken rotor bars, bearing wear and misalignment leave typical patterns, and the measurement needs only clamp-on current sensors.

OperationsRelated: Condition monitoring, CT, Vibration monitoring

MCU (microcontroller)

A small computer on a single chip with processor, memory and peripherals such as timers, ADCs and serial ports. Most sensors and battery devices run on an MCU because it can sleep at microamps and wake in microseconds.

Devices and sensorsRelated: Firmware, GPIO, Sleep mode

MDM (meter data management)

Software that collects, validates, estimates and stores readings from many utility meters before they go to billing and analysis. It fills gaps, flags suspicious values and keeps the history that settlement and disputes depend on.

EnergyRelated: Smart meter, AMR, Data quality

Measurement uncertainty

The range within which the true value of a measurement is expected to lie, such as 20.3 °C ± 0.2 °C. Every reading has some; stating it honestly is what makes comparisons and alarm limits meaningful.

StandardsRelated: Accuracy and precision, Calibration, Resolution

Medium voltage (MV)

The voltage range between low-voltage consumer supply and high-voltage transmission, commonly about 1 kV to 36 kV. Distribution networks, larger factories and substations run at medium voltage, and their switchgear and transformers are frequent monitoring targets.

EnergyRelated: Substation, Transformer monitoring, IEC 61850

MEMS (micro-electro-mechanical systems)

Tiny mechanical structures built on silicon chips alongside electronics. Most low-cost accelerometers, gyroscopes, pressure sensors and microphones in IoT devices are MEMS parts.

Devices and sensorsRelated: Accelerometer, Sensor, Vibration monitoring

MES (manufacturing execution system)

The software layer that runs and tracks production on the shop floor: orders, materials, quality and output, between the machines and the business systems. It records what was made, when, from which materials and with what quality results.

ManufacturingRelated: ISA-95, OEE, SCADA

Mesh network

A network in which devices pass each other’s messages along, so data can hop around obstacles and the network heals when one node fails. Zigbee, Thread and BLE mesh work this way.

ConnectivityRelated: Zigbee, Thread, BLE

Message broker

A server that receives messages from senders and delivers them to the receivers that subscribed to them. In MQTT it is simply called the broker.

ProtocolsRelated: MQTT, Publish-subscribe, AMQP

Message deduplication

Discarding copies of a message that arrive more than once, for example when several LoRaWAN gateways hear the same uplink or an MQTT QoS 1 message is resent. Without it, counters and totals are counted twice.

Data and analyticsRelated: MQTT QoS, LoRaWAN gateway, Network server

Message queue

A buffer that holds messages until a consumer takes them, so senders and receivers do not have to be online or equally fast at the same time. Queues smooth bursts of telemetry and keep data safe while a back-end service restarts.

Data and analyticsRelated: Message broker, Queue, AMQP

Metadata

Data about data: a device’s location, model, installation date, unit of measure or the meaning of a register. Good metadata lets readings be found, compared and trusted long after the people who installed the device have moved on.

Data and analyticsRelated: Tag, Digital twin, Data model

Methane leak detection

Finding escaping methane at wells, pipelines, compressor stations, landfills or biogas plants with fixed gas sensors, optical cameras or periodic surveys. Continuous sensors with alarms shorten the time a leak runs, which matters for safety and for emissions reporting.

EnergyRelated: Pipeline leak detection, Gas detector, Alarm

MFA (multi-factor authentication)

Signing in with two or more independent proofs, such as a password plus a code from an app or a security key. It stops most account takeovers that start with a stolen or guessed password.

SecurityRelated: SSO, OTP, RBAC

MIC (message integrity code)

A short code computed from a message and a secret key, added to the message so the receiver can check it was not changed and came from a key holder. Every LoRaWAN frame carries one.

SecurityRelated: AES-128, Session keys, Frame counter

Microgrid

A local group of generators, storage and loads that can run connected to the main grid or on its own. Campuses, ports and remote sites use microgrids for resilience and to use more local solar or wind.

EnergyRelated: PV (photovoltaic) system, BESS, Peak shaving

Microservices

An architecture in which an application is built from small, separately deployed services that talk over the network. IoT platforms often split ingestion, rules, storage and user interfaces this way so each can scale on its own.

Data and analyticsRelated: IoT platform, Ingestion, Orchestration

Middleware

Software that sits between devices or applications and handles common jobs such as messaging, protocol conversion, security and data routing. An IoT platform is largely middleware between field devices and business systems.

Data and analyticsRelated: IoT platform, Message broker, Protocol converter

Milk cooling monitoring

Watching the temperature of milk in farm bulk tanks and how fast it cools after each milking. Alerts on slow cooling or a failed compressor protect milk quality before collection.

AgricultureRelated: Cold chain, Threshold, Data logger

MIMO (multiple input, multiple output)

A radio technique that uses several antennas at both ends to send parallel streams or make a link more robust. It raises throughput in Wi-Fi and LTE/5G, while most low-power IoT devices use a single antenna to save cost and energy.

ConnectivityRelated: Antenna, Wi-Fi, Cellular IoT

MKT (mean kinetic temperature)

A single temperature that has the same overall effect on product degradation as the varying temperatures actually recorded. It weights warm periods more than a plain average and is used to judge temperature excursions in pharma storage and transport.

LogisticsRelated: Cold chain, Temperature excursion, Data logger

MNO (mobile network operator)

A company that owns and runs a cellular network and its radio licences. IoT SIMs come either directly from an MNO or from an MVNO that resells access, sometimes across several MNOs.

ConnectivityRelated: MVNO, SIM, Roaming

Modbus coil

A single on/off value in a Modbus device that can be read and written, typically mapped to a relay output or a command bit. Coils are read with function code 01 and written with 05 or 15.

ProtocolsRelated: Modbus register, Modbus function code, Digital output

Modbus exception code

The error a Modbus device returns when it cannot carry out a request, for example 02 for an illegal data address or 04 for a device failure. Logging these codes quickly shows wrong register maps or overloaded slaves.

ProtocolsRelated: Modbus function code, Modbus register, Modbus RTU

Modbus function code

The number in a Modbus request that says what to do, such as 03 read holding registers, 04 read input registers, 06 write one register or 16 write several. Devices support only some codes, so the device manual decides which can be used.

ProtocolsRelated: Modbus register, Modbus coil, Modbus exception code

Modbus gateway (TCP to RTU)

A device that lets Modbus TCP clients on Ethernet talk to Modbus RTU devices on an RS-485 line, translating frames and addresses. It is the usual way to bring serial meters and drives onto an IP network.

ProtocolsRelated: Modbus TCP, Modbus RTU, Protocol converter

Modbus register

A numbered 16-bit slot in a Modbus device’s data table. Holding registers can be read and written, input registers only read; a 32-bit value spans two registers, and devices differ in the order of their words and bytes.

In Hermetry Try the Modbus register decoder on our tools page to read 16- and 32-bit values in every word and byte order. Open the tool

ProtocolsRelated: Modbus RTU, Modbus TCP, Scaling

Modbus RTU

The serial form of Modbus, usually over RS-485: one master asks numbered devices for register values in turn. It is simple, old and still on almost every meter, drive and controller.

In Hermetry Gateways read Modbus RTU devices and bring each one into Hermetry as a child device. More about Modbus RTU

ProtocolsRelated: Modbus TCP, RS-485, Modbus register

Modbus RTU over TCP

Sending complete Modbus RTU frames, including their CRC, inside a TCP connection, often through a serial-to-Ethernet converter. It differs from Modbus TCP, which drops the CRC and adds its own header, so both sides must agree on which form they use.

ProtocolsRelated: Modbus RTU, Modbus TCP, Protocol converter

Modbus TCP

Modbus over Ethernet and IP, normally on TCP port 502. The registers and functions are the same as in Modbus RTU; only the framing and the network differ.

In Hermetry Hermetry Edge, on the gateways Hermetry supports, can read Modbus TCP devices, depending on the gateway model. More about Modbus TCP

ProtocolsRelated: Modbus RTU, Modbus register, Protocol converter

Modbus unit ID (slave address)

The address, 1 to 247, that tells devices on a Modbus RTU bus which one a request is for. Every device on one line needs a different address; on Modbus TCP the field selects a device behind a gateway.

ProtocolsRelated: Modbus RTU, Modbus gateway, RS-485

Modulation

The way information is put onto a radio carrier, by changing its amplitude, frequency or phase. Different modulations trade data rate against range and robustness, for example chirp spread spectrum in LoRa or narrowband modulation in cellular IoT.

ConnectivityRelated: LoRa, Bandwidth, Data rate

Motion sensor

A sensor that detects movement, most often a passive infrared sensor that reacts to body heat. In buildings it switches lights and ventilation; in security it raises alerts; in IoT it often wakes a sleeping device.

Devices and sensorsRelated: PIR sensor, Occupancy sensor, Accelerometer

Moving average

An average taken over a sliding window of recent readings, such as the last ten samples or the last hour. It smooths noise so trends and alarm thresholds react to real changes rather than single spikes.

Data and analyticsRelated: Downsampling, Deadband, Anomaly detection

MPC (model predictive control)

An advanced control method that uses a model of the process to predict the next steps and choose the best control moves within limits. It is used where several variables interact, such as in chemical plants or building energy optimisation.

Automation and controlRelated: PID controller, Process control, Setpoint

MPPT (maximum power point tracking)

A control method in solar charge controllers and inverters that keeps panels at the voltage where they deliver most power. Small MPPT chargers also make solar-powered IoT devices work better in poor light.

EnergyRelated: PV (photovoltaic) system, Energy harvesting

MQTT

A light publish-subscribe messaging protocol over TCP. Devices keep one connection to a broker, publish readings on topics and receive commands on the topics they subscribe to.

In Hermetry Devices connect to Hermetry over MQTT 3.1.1 with TLS on port 8883. More about MQTT

ProtocolsRelated: MQTT topic, MQTT QoS, Message broker

MQTT 5

The current major version of MQTT, adding reason codes, user properties, message and session expiry, shared subscriptions and request/response patterns. Many devices still use version 3.1.1, and brokers usually support both.

ProtocolsRelated: MQTT, MQTT shared subscription, MQTT persistent session

MQTT bridge

A link between two MQTT brokers that forwards chosen topics from one to the other. It connects a site broker to a cloud broker, so local systems keep working when the connection drops and data catches up afterwards.

ProtocolsRelated: Message broker, MQTT topic, Store and forward

MQTT persistent session

A session the broker keeps after a client disconnects, with its subscriptions and the QoS 1 and 2 messages it missed. The client asks for it with clean session off (MQTT 3.1.1) or a session expiry (MQTT 5).

In Hermetry Hermetry asks devices to connect with a clean session and serves a request for a persistent one as clean. More about MQTT persistent session

ProtocolsRelated: MQTT QoS, MQTT 5, Keep-alive

MQTT QoS (quality of service)

The delivery guarantee of an MQTT message: 0 at most once, 1 at least once (duplicates possible), 2 exactly once. Higher levels cost more round trips.

In Hermetry Hermetry asks devices to publish with QoS 1, accepts QoS 0 and handles QoS 2 as QoS 1; it acknowledges a message only after it is safely queued. More about MQTT QoS

ProtocolsRelated: MQTT, MQTT retained message

MQTT retained message

A message the broker keeps as the last known value of a topic and hands to every new subscriber at once. It is useful for states such as "online" or a current setting.

In Hermetry Hermetry ignores the retain flag on device messages: the message is processed, not retained. More about MQTT retained message

ProtocolsRelated: MQTT, MQTT topic, Last will

MQTT shared subscription

A subscription shared by a group of clients, where the broker hands each message to only one of them. It spreads the processing of a busy topic across several back-end workers.

ProtocolsRelated: MQTT 5, Message broker, MQTT topic

MQTT topic

The address of an MQTT message, a path such as site/pump-3/temperature. Subscribers can use wildcards: + matches one level, # matches all levels below.

In Hermetry All topics of Hermetry’s default scheme start with v1/, such as v1/telemetry for readings. More about MQTT topic

ProtocolsRelated: MQTT, Publish-subscribe

MQTT wildcard

A placeholder in an MQTT subscription: + matches exactly one topic level and # matches all remaining levels. Wildcards let one subscription cover many devices, but they cannot be used when publishing.

ProtocolsRelated: MQTT topic, Publish-subscribe, MQTT

MQTT-SN (MQTT for sensor networks)

A variant of MQTT for devices on non-TCP networks such as UDP, Zigbee or other low-power radios. It shortens topic names to numeric IDs and needs a gateway that translates to standard MQTT.

ProtocolsRelated: MQTT, UDP, Gateway

MTBF (mean time between failures)

The average running time between one failure and the next for equipment that is repaired. Rising MTBF means the equipment is getting more reliable.

OperationsRelated: MTTR, Availability, Predictive maintenance

mTLS (mutual TLS)

A TLS connection in which both sides prove who they are with certificates, not only the server. A device with its own certificate cannot be impersonated by someone who only knows a password.

In Hermetry Supported devices log in to Hermetry with an X.509 client certificate from Hermetry’s own device certificate authority. More about mTLS

SecurityRelated: TLS, X.509 certificate, PKI

MTTD (mean time to detect)

The average time between a fault or incident starting and someone noticing it. Monitoring with good alarms shortens it, and in remote assets it is often the largest part of the total outage.

OperationsRelated: MTTR, Alarm, Heartbeat

MTTF (mean time to failure)

The average time a non-repairable item runs before it fails, such as a battery or a sensor that is replaced rather than repaired. For repairable equipment the related figure is MTBF.

OperationsRelated: MTBF, MTTR

MTTR (mean time to repair)

The average time from a failure until the equipment works again, including finding, travelling and fixing. Faster alarms and remote diagnosis shorten it.

OperationsRelated: MTBF, Availability, Remote access

MTU (maximum transmission unit)

The largest packet a network link carries without splitting it. Cellular IoT, VPN tunnels and satellite links often have smaller MTUs, and oversized packets then fragment or get dropped.

ConnectivityRelated: UDP, VPN, Packet loss

Multi-tenancy

One system serving several customers or organisations, each seeing only its own devices, data and users. It matters for service providers that run many clients on one platform.

In Hermetry Hermetry keeps organisations apart in the database with row-level security, so one organisation can never read another’s rows. More about Multi-tenancy

OperationsRelated: RBAC, Data residency

Multicast

Sending one message to a group of devices at once instead of to each in turn. LoRaWAN uses it for firmware updates and group commands.

ConnectivityRelated: FUOTA, Downlink

Multipath propagation

Radio signals arriving by several paths, reflected by buildings, ground or metal, and interfering with each other at the receiver. It causes fades that shift when someone or something moves, which is why signal strength in factories and cities varies from metre to metre.

ConnectivityRelated: Path loss, Antenna

MVNO (mobile virtual network operator)

An operator that sells mobile service over other operators’ networks without owning radio infrastructure. IoT-focused MVNOs often offer one SIM that roams on several networks, plus management tools for large fleets.

ConnectivityRelated: MNO, SIM, Roaming