IoT glossary: L

IoT and SCADA terms starting with L: Ladder logic, LAN, Last mile, Last will and 48 more, each with a plain definition.

IoT and SCADA terms starting with L include LTE-M, LoRaWAN, LwM2M and Last will. Each of the 52 entries has a plain definition, its topic and related terms, and how Hermetry handles it where it does.

52 terms on this page · Search all 1,000 terms · Download the whole glossary (PDF, 1.8 MB, 80 pages)

L

Ladder logic

A graphical PLC programming language that looks like electrical relay diagrams, with contacts and coils on rungs. It is one of the IEC 61131-3 languages and is still the most common in machine control.

Automation and controlRelated: PLC, IEC 61131-3

LAN (local area network)

A network that connects devices within a building, site or plant, usually over Ethernet and Wi-Fi. Industrial sites often split their LAN into separate segments for office, control and devices.

ConnectivityRelated: Ethernet, VLAN, WAN

Last mile (delivery)

The final step of delivering goods from a local hub to the customer, often the most expensive part of logistics. Vehicle tracking, temperature monitoring and proof of delivery data help manage it.

LogisticsRelated: Fleet management, Cold chain, Asset tracking

Last will (MQTT LWT)

A message an MQTT client leaves with the broker when it connects. If the client disappears without saying goodbye, the broker publishes the message, so others learn the device went offline.

In Hermetry Hermetry allows a will message but ignores it; it decides a device’s connection state itself. More about Last will

ProtocolsRelated: Keep-alive, MQTT, Heartbeat

Latched alarm

An alarm that stays active after its condition has gone away, until someone acknowledges or resets it. Latching makes sure brief events, such as a short pressure spike, are not missed.

Automation and controlRelated: Alarm, Acknowledgement

Latency

The time between something happening and the data about it arriving where it is used. Monitoring can live with seconds; closed-loop control needs milliseconds and stays local.

Data and analyticsRelated: Jitter, Real time, Edge computing

LBT (listen before talk)

A rule that a radio must check that a channel is free before transmitting, instead of or as well as obeying a duty-cycle limit. Some regions require it in licence-free bands to share the spectrum fairly.

ConnectivityRelated: Duty cycle, ISM band, FHSS

LDAP (Lightweight Directory Access Protocol)

A protocol for reading and managing a directory of users, groups and devices. Applications use it to check sign-ins and group membership against a company’s central directory.

SecurityRelated: SSO, RBAC

Leachate monitoring

Measuring the level and quality of liquid that drains through a landfill, which must be collected and treated before it reaches groundwater. Level sensors and pumps in leachate wells are monitored remotely.

WaterRelated: Groundwater monitoring, Level sensor, Water quality monitoring

Leak detection

Finding leaks from data: flow at times when nothing should flow, water balance gaps, pressure drops or acoustic signals. Fast detection limits damage and water loss.

In Hermetry The server room use case brings leak detection into Hermetry next to temperatures, humidity and UPS values. More about Leak detection

WaterRelated: Night flow, DMA, NRW

Leak noise logger

A small acoustic sensor attached to water pipes or valves that listens at night for the noise of leaks. Comparing loggers along a pipe narrows down where a leak is, before it surfaces.

WaterRelated: Leak detection, Night flow, NRW

Lean manufacturing

A way of running production that removes waste, such as waiting, overproduction and defects, and keeps work flowing to customer demand. Machine data shows where the waste really is.

ManufacturingRelated: Kanban, OEE, Takt time

Legionella

Bacteria that grow in warm water systems and cause a serious lung infection when inhaled in droplets. Water systems are kept below 20 °C or above 50–60 °C, and temperature monitoring of outlets and tanks proves it.

BuildingsRelated: Water quality monitoring, Heat meter

Level crossing

A place where a road or path crosses a railway at the same level, protected by barriers, lights and train detection. Remote monitoring reports barrier position, lamp failures, power and faults to maintenance teams.

In Hermetry The level crossing use case watches crossings and signalled junctions in Hermetry through their controllers’ status outputs. More about Level crossing

Smart cityRelated: Interlock, Traffic signal controller

Level sensor

A sensor that measures how full a tank, well, silo or channel is, using pressure, radar, ultrasound, float, capacitance or other methods. Level is one of the most monitored values in water, fuel and process plants.

Devices and sensorsRelated: Hydrostatic level sensor, Ultrasonic level sensor, Radar level sensor

LiDAR

A sensor that measures distance by timing laser pulses reflected from objects, building a precise 3D picture of its surroundings. It is used for people counting, traffic, volume measurement of stockpiles and autonomous vehicles.

Devices and sensorsRelated: Radar level sensor, People counting, Machine vision

Lifecycle management (device)

Managing a device from manufacture and provisioning through configuration, updates and monitoring to decommissioning. Platforms track each stage so that nothing is forgotten, such as revoking the credentials of a retired device.

OperationsRelated: Provisioning, OTA, Decommissioning

Lighting control

Switching and dimming lights by schedule, occupancy, daylight or command, from single rooms to whole streets. Connected lighting also reports burning hours, energy use and failed lamps.

BuildingsRelated: Occupancy sensor, DALI, Smart lighting

Lightning surge

A short, very high voltage pulse induced in cables by a nearby lightning strike or switching event. Outdoor sensors, antennas and long field cables need surge protection on power and signal lines.

Devices and sensorsRelated: Surge protection, Galvanic isolation, EMC

Limit switch

A switch operated by the movement of a machine part, used to detect end positions of doors, valves, gates and conveyors. Its contact is wired to a digital input and often to safety interlocks.

Devices and sensorsRelated: Digital input, Inductive proximity sensor, Interlock

Line of sight

A clear straight path between two antennas. Higher-frequency and long-range links need it, while lower frequencies bend and pass through obstacles better; see also the Fresnel zone.

ConnectivityRelated: Fresnel zone, Link budget, Antenna

Linearisation (sensor)

Correcting a sensor whose output is not proportional to the measured value, using a formula or a lookup table. Thermocouples, tank volume from level and some flow devices all need it.

Devices and sensorsRelated: Scaling, Calibration, Thermocouple

The sum of gains and losses between a transmitter and a receiver, in dB: transmit power, antenna gains, cable and path losses against the receiver’s sensitivity. It shows whether, and with how much margin, a link will work.

ConnectivityRelated: RSSI, SNR, Spreading factor

Lithium thionyl chloride battery (Li-SOCl₂)

A primary (non-rechargeable) battery with very high energy density and very low self-discharge, which lasts more than ten years in sensors that send little. It cannot deliver large current pulses on its own, so it is often paired with a capacitor.

Devices and sensorsRelated: Battery life, Supercapacitor, Low-power mode

Lithium-ion battery

A rechargeable battery with high energy density, used in trackers, phones and devices with solar panels. It ages with charge cycles and heat and must not be charged below freezing.

Devices and sensorsRelated: Battery life, Energy harvesting, Battery management system

Load balancing

Spreading incoming connections or requests across several servers so no single one is overloaded and a failed server is bypassed. Device brokers and APIs are load balanced to handle large fleets.

Data and analyticsRelated: Horizontal scaling, High availability, Message broker

Load cell

A sensor that converts force or weight into an electrical signal, usually with strain gauges. Load cells weigh silos, tanks, trucks and bins, and monitor loads on cranes and structures.

Devices and sensorsRelated: Strain gauge, Weighbridge, Level sensor

Load factor

Average power over a period divided by peak power in the same period, in percent. A low load factor means short, high peaks, which raise demand charges and the size of the connection a site needs.

EnergyRelated: Peak shaving, Demand charge, Load profile

Load management

Controlling when and how much power loads draw, such as EV chargers, heat pumps or pumps, to stay within a limit or use cheaper hours. It lets a site add loads without a bigger grid connection.

EnergyRelated: EV charger, Load shedding, Demand response

Load profile

A record of power demand over time, usually in 15-minute or hourly steps. It shows when a site uses energy and where peaks come from.

EnergyRelated: Demand charge, Energy monitoring, Peak shaving

Load shedding

Switching off less important loads on purpose to keep total demand under a limit, such as a contract peak or the capacity of a generator. Automatic load shedding acts in seconds based on live power readings.

EnergyRelated: Peak shaving, Demand response, EMS

Local/remote mode

A switch or setting that decides whether equipment takes commands from the panel next to it or from a remote control system. Remote commands are refused in local mode, so people working on a machine are not surprised.

Automation and controlRelated: Interlock, Command, SCADA

Log management

Collecting, storing and searching the event logs of devices, gateways and servers in one place. It helps engineers find the cause of faults and security teams spot attacks.

OperationsRelated: Audit log, Data retention

Long polling

A way for a client to get updates over plain HTTP: it sends a request that the server holds open until there is news or a timeout, then sends another. Devices that cannot keep a socket open can receive commands this way.

ProtocolsRelated: HTTP, WebSocket, Polling

Loop tuning

Adjusting the settings of a control loop, usually the PID gains, so the process reaches its setpoint quickly without overshoot or oscillation. Badly tuned loops waste energy and wear valves and pumps.

Automation and controlRelated: PID controller, Setpoint, Control loop

Loop-powered device

A transmitter that takes its operating power from the same two wires as its 4–20 mA signal, so it needs no separate supply. The 4 mA live zero is what leaves enough current to run the electronics.

Devices and sensorsRelated: Current loop, HART, Analog input

LoRa

A spread-spectrum radio modulation that reaches several kilometres at very low power by trading speed for range. LoRaWAN is the network protocol built on top of it.

ConnectivityRelated: LoRaWAN, Spreading factor, LPWAN

LoRaWAN

An open low-power wide-area network protocol on top of LoRa radio. Battery sensors send small messages over kilometres to gateways, which pass them to a network server.

In Hermetry Hermetry runs its own LoRaWAN network server, so LoRaWAN gateways and devices connect to it directly. More about LoRaWAN

ConnectivityRelated: LoRa, LoRaWAN gateway, Network server

LoRaWAN gateway

A radio receiver that hears LoRaWAN devices nearby and forwards their frames to a network server, and sends downlinks back. One gateway can serve thousands of devices.

In Hermetry You add LoRaWAN gateways to Hermetry and watch their status and position on a map. More about LoRaWAN gateway

ConnectivityRelated: Gateway, Basics Station, Backhaul

LoRaWAN relay

A LoRaWAN feature in which a battery device forwards frames between end devices out of gateway range and a gateway. It extends coverage into basements and remote corners without adding a full gateway.

In Hermetry Hermetry shows LoRaWAN relays and routers running in local mode, which run a network server on the router itself. More about LoRaWAN relay

ConnectivityRelated: LoRaWAN, LoRaWAN gateway, Extended coverage

Lot traceability

Being able to follow a batch of product or material forward to where it went and back to where it came from, together with its process data. Food and pharma regulations require it for recalls.

ManufacturingRelated: MES, Golden batch, Cold chain

LOTO (lockout/tagout)

A safety procedure that isolates machines from energy sources and locks and tags the isolation before maintenance, so nobody can restart them by accident. Digital LOTO records who isolated what and when.

OperationsRelated: Interlock, Work order, Functional safety

Low-code

Building applications, flows or dashboards by configuring visual blocks instead of writing much code. In IoT it lets engineers create rules and automations themselves, with code kept for the unusual cases.

Data and analyticsRelated: Rules engine, Dashboard

Low-power mode (sleep)

A state in which a device switches off most of its circuits and wakes only on a timer or an interrupt. Battery sensors spend nearly all their time asleep; the sleep current largely decides how many years a battery lasts.

Devices and sensorsRelated: Battery life, PSM, Interrupt

LPWAN (low-power wide-area network)

A class of networks that send small amounts of data over long distances with very little energy, so sensors run for years on a battery. LoRaWAN, NB-IoT and LTE-M are examples.

ConnectivityRelated: LoRaWAN, NB-IoT, LTE-M

LTE (Long Term Evolution)

The 4G cellular standard that provides most mobile data today. IoT uses its low-power variants, LTE-M and NB-IoT, and categories such as Cat 1 for devices that need more bandwidth.

ConnectivityRelated: LTE-M, NB-IoT, LTE Cat 1

LTE Cat 1

A low-rate LTE device category, up to about 10 Mbit/s down, that works on ordinary 4G networks. It suits gateways and trackers that need more speed than LTE-M but not a full smartphone modem.

ConnectivityRelated: LTE-M, NB-IoT, Cellular IoT

LTE Cat-M1

The device category name for LTE-M in the mobile network specifications. See LTE-M.

ConnectivityRelated: LTE-M, Cellular IoT

LTE Cat-NB1

The device category name for the first release of NB-IoT in the mobile network specifications; later releases added Cat-NB2. See NB-IoT.

ConnectivityRelated: NB-IoT, Cellular IoT

LTE-M (LTE Cat-M1)

A low-power cellular technology for IoT on 4G networks. It allows mobility and voice and has more bandwidth than NB-IoT, while still saving energy with sleep modes.

In Hermetry Gateways and devices with LTE-M connectivity are listed in Hermetry’s device catalogue. More about LTE-M

ConnectivityRelated: NB-IoT, Cellular IoT, PSM

Lux

The unit of illuminance, the amount of light falling on a surface. Light sensors measure lux so lighting control can dim lights when daylight is enough and keep workplaces at the required level.

BuildingsRelated: Lighting control, Occupancy sensor

LwM2M (Lightweight M2M)

An open device management standard built on CoAP, with standard objects for things like firmware, connectivity and sensors. It covers registration, reading, writing and updates of constrained devices.

ProtocolsRelated: CoAP, Fleet management, OTA