Wrong times and gaps

Readings at the wrong time, refused for their time stamp, duplicated or missing, and charts with gaps or smoothed lines – causes and fixes.

This page helps when readings appear at the wrong time, disappear because of their time stamp, or when a chart shows gaps, flat lines or less detail than you expect. Most of these problems come from the device’s clock, from the form of the time stamp, or from how long windows are read.

Readings at the wrong time

SymptomCauseFix
Readings are hours offThe device sends ts in local timets is milliseconds since 1970 in UTC. Send UTC, or send flat objects without ts and let Hermetry stamp the arrival time.
Readings are in 1970, or refusedThe device sends ts in secondsMultiply by 1,000, or leave ts out
Readings drift a little more every dayThe device clock is not synchronisedUse NTP, or leave ts out
All readings of a batch have the same timeThe device stamps the send time, not the measuring timeStamp each record when it is measured
The Telemetry tab’s Updated time is old although the device reportsThe device sends an old or fixed tsSend the measuring time; check the clock after a battery change

Everything is stored in UTC. The console, dashboards and exports show times in the viewer’s time zone (set under My Profile). Two people in different zones see the same reading at different clock times.

Rule of thumb: send ts only when the device’s clock is synchronised. A device without a reliable clock should send flat objects.

Readings refused for their time

CodeWhenFix
bad_tsts is not an integer of epoch millisecondsFix the form
bad_tsMore than 10 minutes in the future when it arrivesFix the clock. Administrators can change Future timestamp tolerance (minutes) (1 to 1,440) under Settings > Telemetry.
bad_tsOlder than Oldest accepted reading (days) (0 = any age, the default)Expected when that setting is used to stop very old replays
too_oldOlder than your retention class keeps raw readingsCannot be changed by a setting. See the table below.
Retention classReadings older than this are refused
7 days7 days
30 days7 days
90 days30 days
365 days90 days
1,095 days90 days

The run records of the root flow show these codes. See Timestamps, late and duplicate readings.

Readings sent after an outage

What you seeWhy
Buffered readings appear in the history but the latest value did not changeOlder readings never replace a newer latest value
Alarms opened from the buffered data are marked Backfilled, and nobody was toldAlarm rules evaluate late readings as backfill: the history is complete, nobody is paged for the past
Some buffered readings are missingThey were older than the raw window (too_old), or the replay was faster than the profile’s Replay messages per second
A flow that forwards data did not send the backlogMessages processed more than 5 minutes late are marked late; blocks that act outside the platform skip them unless their late setting is send

Duplicates and corrections

SymptomCause
A reading sent twice is stored onceExpected: the same values at the same time for the same device are stored once
A corrected value does not showIt was sent with the same ts as the original. The latest value keeps the first one it saw for that time stamp. Send the correction with a new ts.
The same value twice without ts is stored twiceWithout ts or a message id, two sends are two readings

Gaps on charts

SymptomCauseFix
No data for this periodThe device sent nothing in the window, or the key is misspelledCheck the device’s Telemetry tab; pick a longer window
A text or true/false key draws nothingOnly numbers have a chart history; text and booleans have no summariesStore a numeric copy (for example door_open as 0/1). See Numbers, text and true/false values.
A gap where the device was offlineNo readings were storedExpected. Buffer on the device and send with ts after the outage.
Older parts of a long window are emptyThe window reaches past what is kept: raw readings 7 to 90 days, minute summaries at most 31 daysUse a coarser interval (hour or day) for long windows. See How long data is kept.
An API request answers 400 range_too_largeMore than 10,000 buckets at the chosen resolutionAsk for a coarser bucket or a shorter window

Smoothed or flat lines

SymptomCause
A long window looks smoother than the last dayWindows longer than 24 hours read minute, hour or day summaries instead of every reading
Peaks disappear on a long windowThe aggregate is avg. Use max to keep peaks, min for dips.
A counter (kWh, m³) shows a rising line instead of consumptionUse the aggregate increase; a drop is taken as a counter restart
A daily figure does not match your local dayDay summaries run midnight to midnight UTC. For local days, read hourly figures and add them up by local day. See Aggregates and rollups.
A fresh reading is missing from a long-window chartSummaries are filled every minute; wait a minute or two

Schedules at the wrong hour

WhereTime zone used
A flow’s Schedule blockIts tz setting; empty uses the organisation’s default zone
A Rules-card time triggerThe organisation’s time zone
A Rules-card time windowThe place’s time zone
Sunrise and sunsetThe place’s location

See Time, sunrise/sunset, dates and holidays and Locations and time zones.