New: the AI firewall watches the whole platform and explains each incident in plain words. See how it works

Remote access to a router’s panel does not work

Symptom, cause and fix when Open panel is missing or greyed out, a session is refused or ends, the panel does not load, or its pages are slow.

This page helps when you cannot open a licensed router’s own web panel from Hermetry, or the panel stops working while you use it. It is written for the administrators who maintain routers. How remote access works is in Remote access to a router’s panel; the limits and the end reasons are in Remote access limits and audit.

Start from the router’s device page and from Panel sessions (address /admin/iot/remote-access in your organisation). An ended session shows a reason code in Ended because; the tables below use the same codes.

The Open panel button is missing

SymptomCauseFix
No Open panel button on any device pageYour role or groups lack the permission Open, enter and close the web panel of a claimed router (Admin by default)Ask an administrator for it. See Groups and permissions.
No button on this device onlyThe device is not a claimed licensed router. Panel access exists only for licensed routers claimed with their serial and claim code.Claim the router first. See Licensed devices.
The button was there and is goneThe router was released from your organisationClaim it again if it should be yours.

The Open panel button is greyed out

Hold the pointer over the greyed button: its tooltip names the reason. The checks run in this order, and the first one that fails is shown.

TooltipCauseFix
“Panel access is not set up on this installation.”The platform has no panel tunnel on this installationContact support. See Getting help.
“This router’s firmware does not support panel access yet.”The router has not announced panel support when it connectedUpdate the router’s firmware, then let it reconnect.
“The device is not active.”The device is disabled or quarantinedEnable or activate the device.
“The router has no valid certificate.”The router has no active certificate, or its certificate is revoked or expiredProvision the router again so it gets a new certificate. See Device certificates.
“The router is offline.”The router has no live connection to HermetryCheck the router’s power and uplink. The button works again when the router is back online.

Opening a session is refused

You select Open panel and a message appears next to the button.

MessageReason codeCauseFix
“This router already has 3 open panel sessions. Close one first.”device_busyA router has at most 3 open sessions, counting every member’sClose a session in Panel sessions. An administrator can close a colleague’s session there.
“Your plan’s limit of open panel sessions is reached.”tenant_limitYour organisation has as many sessions open as its plan allowsClose sessions you no longer use. See Plans and the IoT add-on.
“This month’s panel data allowance is used up.”monthly_bytesThe plan’s monthly panel data is used. Both directions of every session count.Wait for the next month. Sessions already running are not cut off; new ones are refused. See Usage and quotas.
“Panel access is switched off on this router. Switch on “Allow panel access from my cloud account” on the router’s Cloud page.”opt_inThe router owner has not allowed panel access on the router itselfSomeone with access to the router switches it on locally. It cannot be switched on from Hermetry.
“The router refused: it has the most panel sessions it allows.”router_busyThe router counts its own sessions and has no roomClose a session and try again.
“The router refused the panel session.”router_refusedThe router answered with another refusalCheck the router’s own logs, then try again.
“The router did not answer. Try again in a moment.”router_unreachableHermetry waits 15 seconds for the router’s answer and got noneCheck that the router is online, then try again.
“This panel session has ended.”session_closedYou selected Back to panel for a session that has ended meanwhileReload the device page and select Open panel.
“The panel could not be opened. Try again.”Another refusalFor example, too many requests in a short timeWait a moment and try again.

A refused attempt still leaves an ended row in Panel sessions with the reason router_refused or router_unreachable. Plan limits and the 3-per-router limit are in Remote access limits and audit.

Note

On a router that reports its mobile (LTE) uplink, Open panel first asks Open the panel over the mobile link? Nothing is opened until you confirm. Cancel if you do not want to use mobile data.

The session stays on Connecting, then ends

After you open a session, the router must connect out to Hermetry for it. While it does, the panel tab shows Reconnecting to the router and reloads itself every 3 seconds.

SymptomCauseFix
The session ends with no_dialThe router accepted the request but did not connect within 90 secondsCheck that the router’s network allows its outbound connection to Hermetry. See Hostnames, ports and IP addresses.
The session ends with node_lostThe tunnel’s connection on the platform side was lost, and the router did not connect again when asked once moreOpen a new session.

The router proves who it is with its device certificate when it connects. A router whose certificate is not its current, active one cannot attach to the session, and the session ends with no_dial.

The session ends while you work

When a session ends, the panel tab shows This panel session has ended (“Open the panel again from the device page.”). Look up the reason in Ended because.

Reason codeCauseWhat to do
ttl_idle30 minutes without any traffic in the sessionOpen a new session. Any request in the panel resets the 30 minutes.
ttl_hard4 hours since the session was opened, whatever the activityOpen a new session.
lte_capOn a mobile (LTE) uplink, the session moved more data than its cap (50 MB by default, both directions together)Prefer a wired uplink for long work, or open a new session.
userSomeone closed it in Panel sessionsOpen a new one if you still need it.
releasedThe router was released from your organisationThe router is no longer yours to open.
device_goneThe device was deletedNothing to reopen: the device no longer exists.
certificate_revokedThe router’s certificate was revokedProvision the router again.
permission_lostYou lost the panel permission, or your role changedAsk an administrator. A role change always closes your sessions, so they are judged again on your new role.
membership_endedYou left the organisation or were removedAsk to be invited again.
session_revokedYour Hermetry sign-in session ended: you signed out, signed out other devices, changed your password, or an administrator ended itSign in again and open a new session.
tenant_endedThe organisation was suspended or its deletion startedContact the organisation’s owner.
router_closedThe router ended the tunnel, or its connection to Hermetry droppedOpen a new session once the router is back online.
pong_timeoutThe router stopped answering the tunnel’s keep-alive: three missed answers, sent every 20 secondsCheck the router’s uplink, then open a new session.
protocol_error, drainThe link broke, or the platform restarted the tunnel serviceOpen a new session.
supersededThe router connected the session’s tunnel again and the older connection was replacedIf the panel stopped working, open a new session.

A change that ends access (a revoked certificate, a lost permission or membership, a signed-out session, a suspended organisation) closes the tunnel within about a second. A check every 60 seconds catches any change the fast path missed.

The panel does not load

What the tab showsCauseFix
Open the panel from the platform (“This page needs a panel session started from the device page.”)The tab has no valid entry. The entry link works once, within 60 seconds, and only in the browser that used it. Copying the link to another browser or opening it again gives this page.On the device page, select Back to panel. It makes a fresh entry link for your open session.
This panel session has endedThe session is closed or past its 4 hours, or the address belongs to no sessionOpen a new session from the device page.
Reconnecting to the router (reloads by itself)The router is connecting, or connecting againWait. If the session then ends with no_dial, see above.
Temporarily unavailable (reloads by itself)A short platform-side problemWait for the reload.
Too many requests (“Try again in a minute.”)20 refused requests from your address within one minuteWait a minute, then open the panel from the device page.
The router’s own sign-in pageThe panel runs the router’s own sign-inUse the router’s local user and password, as you would on site.

Each session belongs to the person who opened it: colleagues open their own sessions, and only you get Back to panel for yours.

The panel opens on its own web address, separate from Hermetry’s, so a router’s page can never read your Hermetry session. The entry link is exchanged for a cookie that belongs to that panel address only, and the panel opens as a normal tab, so blocking third-party cookies does not stop it. A browser that blocks every cookie for the panel’s address cannot keep the session and shows Open the panel from the platform on each page.

Panel pages are slow

SymptomCauseFix
Large pages, uploads or downloads are slowEach session has a data rate limit over both directions together (2 MB per second by default)Expected for large files. On a mobile uplink, large transfers also count toward the session’s cap.
The router is busy (“Too many requests at once.”), reloads by itselfThe panel opened more than 64 requests at once through one sessionWait for the reload; close other tabs of the same panel.
The router did not answer (“Try again, or open the panel again from the device page.”)The router did not take a request within 10 seconds, or the request brokeReload. If it keeps happening, check the router’s load and uplink.