New: the AI firewall watches every module and explains each incident in plain words. See how it works

Getting help

Where to get help with Hermetry – the docs, the community forum and support – what to include in a question, and what never to send.

When the troubleshooting pages do not solve your problem, ask for help. A good question with the right details is usually answered at the first reply. This page explains where to ask, what to include and what to keep to yourself.

Where to ask

WhereUse it for
These docsSearch first. Each section has its own troubleshooting page, and Troubleshooting lists symptoms across all sections.
The community forumHow-to questions, ideas, sharing flows and boards, and problems other customers may have met. Do not post anything private.
Contact usSupport for your organisation, sales, plans and partnerships; anything that involves your account or data; security reports

Ask Hermetry support (through the contact page) when:

  • a page says to contact support, for example “No worker is running the IoT host right now…” or “This account is locked for security reasons…”,
  • your organisation cannot be reached, is suspended, or is read-only for longer than expected,
  • you need something only Hermetry can do: changing your home region, a full installation of a ready solution, an Enterprise or on-premises agreement,
  • you think you found a security problem.

Before you ask

  1. Read the record of what happened: the device’s Log tab, the root flow’s Activity, the alarm’s timeline, the rule’s History, the command’s history, the audit log.
  2. Reproduce the problem with one device or one board, if you can.
  3. Check In development: the feature may not be available yet.
  4. Check Limits and quotas: a limit may have been reached.
  5. Note the exact message. Copy it rather than describing it.

What to include

DetailExample
Your organisation’s addressacme.<platform domain> (not your password)
The regionEU, US or Türkiye
What you did, step by step“Opened Dashboards > Plant, selected Run pump 1, confirmed”
What you expected and what happened“Expected the pump to start; the control showed Timed out“
When, with your time zone2026-11-09 14:20 Europe/Istanbul
The exact message or codedevice_rate_limited, CONNACK 5, “No rows.”
The thing involvedDevice name and ID, profile name, flow name and slug, board title, alarm type
For an API callMethod, path (without the key), status, response body and the time of the call
For a deviceModel and firmware version, connection type (MQTT, HTTP, LoRaWAN, gateway child), what its own log says

Useful attachments:

  • A screenshot of the page with the message, with secrets hidden.
  • An exported flow: secrets are never in a flow export. See Versions, testing and rollback.
  • An exported board file, when a board misbehaves. See Templates and board files.
  • A recorded message from the flow’s debug panel, with personal data removed.

Never send

Never sendWhy
Passwords, passkeys or second-factor codesNobody at Hermetry needs them, and nobody will ask
Device access tokens, MQTT passwords, private keys, claim codesThey let anyone act as your device. If one was shared, rotate it. See Device credentials.
API keys, webhook signing secrets, SCIM tokensRotate any you shared by mistake. See API key hardening.
Camera passwords, router panel linksRevoke or change them if shared
Personal data you do not need to showRemove names, e-mail addresses and phone numbers from screenshots and messages

On the forum, everything you post is public: describe your setup with example names, never real addresses, keys or customer data.

Security reports

If you believe you found a security problem in Hermetry, report it through the contact page and do not post it on the forum. Include what you found and how to reproduce it, without accessing other customers’ data. See Security.

Planned maintenance and outages

Banners at the top of the console announce planned maintenance. During maintenance or an incident, devices that buffer their readings and send them later with their own time stamps lose no data; alarms raised from that data are marked Backfilled. See Timestamps, late and duplicate readings.