New: the AI firewall watches every module and explains each incident in plain words. See how it works

A dashboard shows no data

Why a card is empty or asks for a value – unbound slots, parameters, key filters, windows, text values, permissions, module access and display links.

This page helps when a dashboard card is empty, shows a message instead of data, or shows data to you but not to a colleague. Read the card’s own message first: most empty cards say what they need.

First: is the data there?

Open one of the card’s devices and its Telemetry tab. If the key is not there, or its Updated time is old, the board is not the problem: see Data does not arrive.

What the card says

The card saysCauseFix
“This card is not finished: choose its … in its settings.”A required data field is emptyOpen the card’s settings and fill it
“Bind a value / a data series / a table query in this widget’s settings.”The value, series or rows slot is emptyBind it
“Choose a value in the filters above to load this widget.”The card follows a parameter that has no value yetPick a value in the filter bar
“ holds N devices; pick one”A card that shows one device takes a parameter that holds a site with several devicesPick one device, or bind the card to The device this page shows
“No data for this period.”Nothing was sent in the window, or the key is misspelledCheck the key on the Telemetry tab; choose a longer window
No values in this window on a chart, while a value card shows a valueThe key is text or true/false: only numbers have a chart historyStore a numeric copy. See Numbers, text and true/false values.
“No rows.”Nothing matches the source’s filters or the windowRelax the key filters; for alarm tables try Ignore the board window
“No rows with valid coordinates.”A map’s latitude and longitude columns are missing, empty or out of rangeCheck the column names; the device must send lat and lng, or you set them
“You may not see the data of this card.”You lack the read permission for that dataAsk an administrator
“Widget not available”The widget’s module is off for your organisation, or you lost access to itRemove from board, or ask for the module
“Not refreshed”Too many requests: the card shows the last data and asks again shortlyWait; lower the card’s refresh rate
“Live updates unavailable — polling”The live connection is not availableCards refresh on their interval; nothing to fix on the board

Parameters and key filters

A board’s parameters decide which devices or sites its cards read.

SymptomCauseFix
The card shows another device than you expectThe page’s parameter was set by the link you opened; your own filter choices win once you change oneCheck the filter bar and the address (?p.device=…)
A hidden page opens emptyA hidden page needs the device or site it shows, set by the row, marker or button that opens itOpen it from the board, not from a bare address
A list stops at 500 devicesA resolved parameter holds at most 500 entities, the first 500 by name; a fixed list at most 100Narrow the parameter, or split the board
Some devices are missing from a listA key filter excludes them, for example “latest temperature above 30″ excludes devices that never sent temperatureCheck Manage key filters…: the key, its type (Text, Number, Boolean, Date and time) and the operation
The board shows nothing after a key was renamedCards and filters still read the old keyUpdate the cards, or rename back in the root flow

See Data sources and parameters.

Windows and aggregates

SymptomCause
A card shows less detail for older daysWindows over 24 hours read summaries, not every reading
Older parts of a long window are emptyRaw readings are kept 7 to 90 days and minute summaries at most 31 days, by your retention class; hour and day figures for the full class. See How long data is kept.
A window of more than a year is refusedThe longest window is 366 days
Counter values look like a rising lineUse the aggregate increase

A colleague sees something different

SymptomCauseFix
A colleague sees an empty card on a shared boardThey lack the read permission for that data (devices, telemetry, alarms), or an access policy hides those devicesCheck their role, groups and policies. See Groups and permissions.
A card is missing for a colleagueIt uses a private widget only its author can seePublish the widget, or replace it
Alarm counts are empty for some peopleAlarm counts need the alarm read permissionGrant View alarms and alarm rules
A camera card is blank for a colleagueWatching needs Watch the live picture of a camera and read access to the camera’s deviceSee Camera limits and privacy
A control is greyed outThe reading is old or unknown, or they may not send that commandSee Control cards
The screen saysFix
“This display link is not valid”Check the address, or create a new link
“This display link was revoked” or “has expired”Create a new link (1 to 365 days)
“Nothing to show”None of the board’s cards can be shown on a display; share the custom widgets it uses
A card is blank on the screenIt is a 3D card (not shown on display links), or the person who made the link may no longer read that data

See Wall screens and full screen.

Ready-solution boards

A board made from a solution template leaves out the cards that read relations or run compute scripts. Cards of a full installation read the solution’s keys; if your devices send other names, see Adapting a solution to your devices.

SCADA and site views

SymptomPage
Symbols do not move or change colourTroubleshooting SCADA
A site or room is UnknownNo device under it sends a status key, has an open alarm or was active in the last 10 minutes. See Site status and the status key.