Telemetry keys

The rules every telemetry key and value must follow, the reserved prefixes, the raw key, topic-prefixed keys, the plan's key cap and profile key settings.

Every reading is a key and a value, for example "temperature": 21.5. This page lists the rules keys and values must follow, what happens to one that breaks a rule, and how to plan your key names.

Key rules

RuleDetail
CharactersA-Z, a-z, 0-9, _, . and - only
Length1 to 64 characters
CaseCase-sensitive: Temp and temp are two keys
Reserved prefixesA key may not start with _, fw_, current_fw_ or cfg.. These belong to attributes (firmware state, desired configuration) and to the platform.

A key that breaks a rule is left out of the record; the other keys of the same record are kept. The drop is reported in the flow’s run record (see the reasons below).

Value rules

ValueStored asLimit
A finite numberA number (charted and aggregated)
true / falseA flag
TextText1,024 characters
A JSON object or arrayJSON4 KiB when written as JSON
nullNothing: “no reading”, not an error

A value over its limit drops its key only. See Numbers, text and true/false values.

A message’s size

A message may hold at most 1,000 key-value points after it is split into records. A message with more is refused as a whole (bad_form); nothing of it is stored. The device’s profile also limits the payload size (64 KiB by default). See Device profiles.

The raw key

A body that is not JSON (binary data, plain text, or a JSON scalar or array on a custom topic) is stored under the single key raw, as text. The raw key is exempt from the 1,024-character limit and is capped by the profile’s Max raw payload (bytes) instead: 4,096 bytes by default, 256 to 65,536 bytes. A binary body arrives base64-encoded (msg.metadata.encoding is base64).

Decode raw in a flow (for example with the Base64, Hex or Bytes blocks, or a script) and save named keys. See Data transform blocks.

Topic-prefixed keys

With the profile setting Prefix keys with the topic, data on a custom topic is stored as <topic>.<key>:

  • / in the topic becomes .; any other character outside the key rule becomes _.
  • The reserved-prefix rule and the 64-character limit apply to the joined key. A joined key over 64 characters is dropped.
  • raw becomes <topic>.raw, with the same raw limits.

Example: topic site1/boiler and key temp give site1.boiler.temp. Without the prefix, the same key arriving on two topics is one key, and the last write wins.

The key cap

Your plan can limit how many distinct keys your organisation stores:

IoT plan tierDistinct telemetry keys
Starter250
Growth400
Scale2,050
  • A key counts once, however many devices send it.
  • A key stays counted after the devices that sent it are deleted: the key dictionary is never pruned.
  • The count is read at most once a minute.
  • A new key over the cap is not stored; the other keys of the record are. When nothing of a record is left, Save telemetry reports key_limit.

Keep key names stable and shared across device types (temperature, not temp_dev42). Put a device’s identity in the device, never in the key.

Profile key settings

The Telemetry keys list of a device profile (up to 500 keys) describes the keys its devices send:

FieldUse
TypeNumber, Whole number, Yes / no, Text or JSON
UnitUp to 32 characters; shown next to values and on chart axes
LabelUp to 128 characters; the name shown instead of the key
Min, MaxThe expected range; a gauge takes it as its default scale
Decimals0 to 10

The list does not filter what is stored: a key that is not listed is still stored. It names and formats keys on the Telemetry tab, in dashboards and in SCADA bindings. See Device profiles.

Why a value was left out

The run record of the root flow and the error of Save telemetry use these codes:

CodeMeaning
key_invalidA character outside the key rule, or an empty key
key_too_longOver 64 characters (also after the topic prefix)
key_reservedStarts with _, fw_, current_fw_ or cfg.
string_too_longText over 1,024 characters
value_too_largeJSON over 4 KiB, raw over its cap, or a number that is not finite
bad_formNot a form the store reads, or more than 1,000 points in one message
bad_tsA timestamp that is not epoch milliseconds, too far in the future or too old for the settings
too_oldOlder than your retention class keeps raw data
key_limitA new key over the plan’s key cap
no_valuesNothing in the record could be stored

Naming tips

  • Use lower case and underscores: flow_rate, pump_1_running.
  • Use dots for structure you want to group: p1.running, p1.value (SCADA element keys use this form).
  • Keep units out of key names; put them in the profile’s Unit.
  • Store states as numeric codes when you need their history. See Numbers, text and true/false values.

See also Reserved keys and attributes.