New: the AI firewall watches every module and explains each incident in plain words. See how it works

Gateway status, health and the map

Read a gateway's state, round trip and health telemetry, use the default health alarms, and place gateways on the gateway map.

Every gateway reports its connection and health to Hermetry. You see the current state on the gateway’s LoRaWAN tab, its health history as ordinary telemetry of its device, and all gateways together on the Gateway map.

Gateway states

BadgeMeaning
OnlineThe gateway’s connection to the network server is open.
OfflineNo connection. The time since it was last seen is shown beside the badge.
DisabledSomeone disabled the gateway. It is refused until enabled again.
PendingA gateway that was seen but not accepted. This state belongs to LoRaWAN relays, which are in development; gateways you add are never pending.

On the map, a gateway that never connected is shown as Never connected.

The gateway’s device follows the Live connection online rule of the built-in LoRaWAN gateway profile: the device is online exactly while its connection is open.

The gateway’s LoRaWAN tab

Open Devices, open the gateway, and select the LoRaWAN tab. The tab is read again every 10 seconds while it is open.

FieldShows
Gateway EUIThe EUI, with a copy button.
ProtocolBasics Station, or the licensed router link.
RegionEU868.
Network serverCloud, or Local (on the gateway).
Round tripAverage time to the gateway and back, in ms. Marked above 800 ms.
Last seenWhen the network server last heard from it.
Connected sinceWhen the current connection opened.
LocationLatitude and longitude (and altitude when known), or Not on the map.

Below the facts are the Connect the gateway steps, Frames this gateway heard (the last day, refreshed while the tab is open), and Devices heard recently (each device with its RSSI, SNR and when it was heard; No device heard in the last day. when empty). Select a device to open it.

Round trip and RX1

A Class A device listens for an answer one RX1 delay after its uplink (5 seconds by default on Hermetry). The network server must hand the answer to the gateway before that moment. A slow internet link at the gateway, such as weak mobile data, eats into this time. When the round trip is above 800 ms, devices with a short RX delay fall back to the second window (RX2). With the default 5-second delay, downlinks still make it.

Health telemetry

Once a minute, while the gateway is connected, the network server writes one health record to the gateway’s device. These are normal telemetry keys: chart them on dashboards and use them in alarm rules.

KeyMeaning
lora.gw.up_rxUplink copies received in the interval
lora.gw.up_uniqueUplinks the gateway contributed after de-duplication
lora.gw.rtt_msAverage round trip in ms
lora.gw.dn_sentDownlinks the gateway confirmed it transmitted
lora.gw.dn_failedDownlinks that failed (refused by the gateway, or the connection was gone)
lora.gw.dn_unknownDownlinks with no result (Basics Station reports no failures)
lora.gw.dn_failed_pctFailed share of downlinks, when any were tried
lora.gw.dc_used_pct.<band>Share of the hourly duty-cycle budget used per EU868 sub-band (K, L, M, N, P, Q)

Licensed routers report more keys; see Licensed routers as LoRaWAN gateways.

When the gateway connects, the network server also stores client attributes: lora.gw.station (gateway software version), lora.gw.firmware, lora.gw.model, lora.gw.protocol, lora.gw.mode and lora.gw.region.

Default health alarms

When alarms are available in your organisation, the built-in LoRaWAN gateway profile gets these rules. Change or switch them off on the profile’s Alarm rules tab.

RuleRaised whenSeverityCleared when
Gateway offlineNo connection for 10 minutesMajor, notifies adminsIt connects again
Round triplora.gw.rtt_ms above 800 for 10 records in a rowWarningBelow 600 for 10 records
Failed downlinkslora.gw.dn_failed_pct above 5 for 3 recordsMinorBelow 2 for 10 records
Duty cycle nearly used upAny lora.gw.dc_used_pct.<band> above 80WarningAll below 60 for 5 records
Offline buffer not draininglora.gw.buffer_oldest_s above 3,600 for 2 records (licensed routers)MinorBelow 1
Temperaturelora.gw.temp_c above 75 for 3 records (licensed routers)Major, notifies adminsBelow 70 for 3 records

The gateway map

  1. Open Devices.
  2. Open the ⋯ menu and select Gateway map.

The map shows every gateway of your organisation (up to 1,000), Basics Station gateways and licensed routers alike, coloured Online, Offline or Never connected. It refreshes every 15 seconds. Select a pin to open the gateway’s device page. Fit all zooms to show every pin.

Gateways without a location are listed under Not on the map. To place one:

  1. Select Place on the map beside it. The pin appears in the middle of the map.
  2. Drag the pin to where the gateway stands.

Each drop is saved at once, rounded to six decimal places. To move a placed gateway, drag its pin. You never type coordinates. Placing and moving needs the permission to manage gateways; others see the map read-only.

You can also set latitude, longitude and altitude through the API with PATCH /tenant/<tenantId>/api/iot/lorawan/gateways/<gatewayId>.