New: the AI firewall watches the whole platform and explains each incident in plain words. See how it works

LoRa link budget and range calculator

Free LoRa link budget calculator: receiver sensitivity per spreading factor, the path loss a link can take and the free-space range from power and gains.

This LoRa link budget calculator adds transmit power and antenna gains, subtracts losses, receiver sensitivity and fade margin, and turns the rest into a free-space distance. Sensitivity = −174 dBm/Hz + 10 log₁₀(bandwidth) + noise figure + the spreading factor’s SNR limit.

Both ends together.

About 6 dB for a typical LoRa receiver.

Room for fading, interference and changes over time.

Set to 0 for a clear line of sight; 10 to 20 dB or more for a device inside a building or among buildings.

Path loss the link can take
– dB
Free-space distance (line of sight)
– km
Receiver sensitivity
– dBm
Radiated power (EIRP)
– dBm

The distance assumes a clear line of sight and nothing else in the way. Buildings, terrain and trees cut it a lot: use it as an upper bound and the path loss to compare set-ups.

How it works

Receiver sensitivity is the weakest signal the gateway can decode: −174 dBm/Hz of thermal noise, plus 10 × log₁₀ of the bandwidth in hertz, plus the noise figure, plus the lowest signal-to-noise ratio the spreading factor can decode (−7.5 dB at SF7, 2.5 dB lower per step, −20 dB at SF12).

The path loss the link can take is the transmit power plus both antenna gains, minus cable losses, minus the sensitivity, minus the fade margin and any extra loss you enter.

Free-space path loss in dB is 20 × log₁₀(distance in km) + 20 × log₁₀(frequency in MHz) + 32.44: 91.2 dB at 1 km on 868 MHz. The distance shown is where that loss equals the budget.

Real links lose more than free space. The extra-loss field lets you add what you expect from walls, terrain and the height of the antennas.

In Hermetry Hermetry shows the RSSI and SNR of every device a gateway hears, so you can check a site against the budget: Gateway status, health and map.

Glossary Link budget, RSSI (received signal strength indicator), SNR (signal-to-noise ratio), Spreading factor (SF)

Questions

How far does LoRa reach?

It depends mostly on what lies between the antennas. The free-space distance here is the line-of-sight upper bound; buildings, terrain and vegetation reduce it, often to a few kilometres in built-up areas. Add the losses you expect in the extra-loss field.

What is a fade margin?

Spare decibels kept in the budget for fading, interference and changes over time. 10 dB is a common starting point; the calculator subtracts it before working out the distance.

Why does a higher spreading factor reach further?

Each step up lets the receiver decode a signal 2.5 dB weaker, at the cost of twice the time on air. SF12 decodes signals about 12.5 dB weaker than SF7.