This VPD calculator subtracts the actual vapour pressure from the saturation pressure, 0.6108 × e17.27T ÷ (T + 237.3) kPa: at 25 °C and 60 % the air VPD is 1.27 kPa, and 0.91 kPa at a leaf 2 °C cooler.
- VPD
- – kPa
- Air VPD
- – kPa
- Leaf VPD
- – kPa
- Saturation vapour pressure
- – kPa
- Actual vapour pressure
- – kPa
The headline value is at the leaf. The headline value is for the air. Below 0.4 kPa: very humid; plants transpire little and disease risk rises.0.4 to 0.8 kPa: suits propagation and young plants.0.8 to 1.2 kPa: suits vegetative growth.1.2 to 1.6 kPa: suits flowering and fruiting.Above 1.6 kPa: dry air; plants may close their stomata and stress. The ranges are a common rule of thumb; crops differ.
Enter a temperature from −20 to 60 °C and a relative humidity from 0 to 100 %.
How it works
How is vapour pressure deficit calculated?
Saturation vapour pressure (kPa) = 0.6108 × e17.27 T ÷ (T + 237.3). Actual vapour pressure = saturation pressure × RH ÷ 100.
Air VPD = saturation pressure at air temperature − actual vapour pressure. Leaf VPD uses the saturation pressure at the leaf temperature instead, since the leaf’s inside is saturated at its own temperature.
At 25 °C and 60 % the air VPD is 1.27 kPa; with leaves 2 °C cooler it is 0.91 kPa at the leaf.
Glossary Sensor, HVAC (heating, ventilation and air conditioning)
Questions
Questions about the VPD calculator
Why use VPD instead of relative humidity?
The same relative humidity dries plants very differently at 15 °C and at 30 °C. VPD measures the drying power of the air directly.
How do I lower VPD?
Raise humidity (misting, fogging, less ventilation) or lower the temperature. Raise it with ventilation, heating or dehumidifying.