And while it’s in Manual, does the Commands part of the card still work? That’s exactly when we’d run the pump by hand.
Zener koruma için yeterli, biz hep öyle yapıyoruz. Düşüklüğü kalibrasyonla düzeltin.
Translated from Türkçe by AI ·
Be careful, the Wi-Fi and Ethernet MAC of the Pi are different. If the Pi’s connect over Wi-Fi, you will see the wlan0 MAC in the DHCP list.
Dikkat, Wi-Fi ile Ethernet MAC’i farklı. Pi’ler Wi-Fi’dan bağlanıyorsa DHCP listesinde wlan0 MAC’i görürsün.
CM4’lerde de aynısını gördük, bu dosya ile düzeldi. +1
Translated from Türkçe by AI ·
Running nmap on the corporate network can give you headaches, the IT team doesn’t really like it.
Kurumsal ağda nmap çalıştırmak başını ağrıtabilir, BT ekibi pek sevmez bunu.
Translated from Türkçe by AI ·
The button idea is good, we also put it inside the panel cover, so it can’t be pressed without opening the cover.
Buton fikri iyi, biz de pano kapağının içine koymuştuk, kapak açılmadan basılamıyor.
Titreşim sensörünü duvara koyarsanız kompresörün titreşimini yakalarsınız, bence iş görür.
Translated from Türkçe by AI ·
If you accept automatically, anyone within range can pair, so be careful. Bluetooth passes through walls even when the panel is locked.
Otomatik kabul edersen menzildeki herkes eşleşebilir, buna dikkat. Pano kilitli bile olsa Bluetooth duvardan geçer.
Uno’nun USB tarafını ana işlemci değil, yanındaki ATmega16U2 yönetiyor ve o sadece seri port gibi davranıyor. 16U2’yi yeniden programlayıp klavye yapanlar var ama zahmetli. Biz ilaç tarafında etiket yazıcısına benzer bir şey yaptık, şöyle kurdum:
Doğrudan USB’si olan bir kart lazım. Leonardo veya Pro Micro (ATmega32u4) Keyboard.h ile klavye olur. Ben ESP32-S3’ü tercih ederim: hem Wi-Fi’si var hem yerel USB’si, tek kart hem Hermetry’ye MQTT ile bağlanıyor hem klavye oluyor. Arduino-ESP32 core’unda USBHIDKeyboard var.
Hermetry tarafında kartın profiline Commands sekmesinden dozaj.yaz diye bir komut ekle, tek parametre: deger (Number, min-max aralığını gir ki saçma bir değer hiç gitmesin). Tier’ı Privileged yap, “High impact” işaretle; gönderen onaylamak zorunda kalır ve kayıt audit log’a düşer.
Kart tarafı kabaca:
void komutGeldi(int id, float deger) {
if (deger < 0.2 || deger > 3.0) { cevap(id, false); return; }
char s[12];
dtostrf(deger, 0, 2, s);
Keyboard.print(s);
Keyboard.write(KEY_RETURN);
cevap(id, true); // v1/rpc/res/{id} {"ok": true}
}
En büyük risk odak: klavye yazdığı yere yazar. Operatör o sırada başka bir pencerede ise değer oraya gider. Biz komuttan önce programın penceresini öne getiren bir kısayol (Alt+Tab değil, programın kendi kısayolu) yazdırdık, sonra alana Tab ile gittik.
Ayşe’nin sorusu birinci sorun, kodunuz da ikinci. İkisini de geçen yıl aynı kurulumda yaşadım.
1. Gerilim: RFM95 3.3 V çipi, SPI pinleri 5 V’a toleranslı değil. Mega’nın MOSI, SCK, NSS ve RESET çıkışları 5 V. Modül bir süre “çalışıyor gibi” yapıyor, sonra kilitleniyor. Araya bir seviye dönüştürücü koyun (74LVC245 ya da en azından MOSI/SCK/NSS’de dirençli bölücü). Modül hasar görmüş olabilir, yenisiyle deneyin. Daha basiti 3.3 V çalışan bir kart.
2. onReceive bir kesmeden çağrılıyor. İçinde Serial.print, String birleştirme ve hele MQTT publish yaparsanız kesme çok uzun sürer, Ethernet shield de SPI’yi kullandığı için LoRa ile aynı hatta çakışıyorlar. Kesmede sadece bayrak kaldırın, işi loop()’ta yapın:
volatile int rxSize = 0;
void onReceive(int size) { rxSize = size; }
void loop() {
if (rxSize) {
char buf[64]; int n = 0;
while (LoRa.available() && n < 63) buf[n++] = (char)LoRa.read();
buf[n] = 0; rxSize = 0;
gonderHermetry(buf);
LoRa.receive(); // tekrar alma moduna al
}
mqtt.loop();
}
Ethernet shield ile RFM95’in CS pinleri ayrı olsun, birini seçerken öbürü HIGH kalsın.
Bizde ilaç tesisinde IO-Link master’lar hazır modüller, kimse kendi master’ını yazmıyor. Sertifikasyonu ayrı dert.
Translated from Türkçe by AI ·
A relay would work too, but for two switchings a day a MOSFET is quieter and cleaner. My suggestion:A logic-level N-channel MOSFET (like IRLZ44N), low-side wiring. The positive of the lamps goes directly to 12V, the negative to the MOSFET’s drain, and the source to the battery (negative). Put a 100 Ω series resistor from the Pi’s GPIO to the gate, and a 10k pull-down between gate and source. Without the pull-down the lamps will flicker while the Pi boots. At 4 A the IRLZ44N runs comfortably without a heatsink. Don’t forget to join the Pi’s negative with the battery’s negative.For scheduling, use the Rules card in Hermetry:
- When: Sunrise or sunset, sunset, offset -15 minutes
- Then: Send command, device Pi, command
light.set, parameteron: true - A second rule: sunrise,
on: false
You need to add the command to the Commands catalog of the device profile. The site’s location must also be entered, otherwise the card won’t save: the location of the nearest asset on the device is used. Details: Rules card: triggers.On the Pi side, subscribe to the topic v1/rpc/req/+, drive the pin when light.set arrives, and reply via v1/rpc/res/<id>. That way the seasonal worry goes away too.
Röle de olur ama günde iki anahtarlama için MOSFET daha sessiz ve temiz. Benim önerim:
Lojik seviyeli N-kanal bir MOSFET (IRLZ44N gibi), low-side bağlantı. Lambaların artısı doğrudan 12V’a, eksisi MOSFET’in drain’ine, source aküye (eksi). Gate’e Pi’nin GPIO’sundan 100 Ω seri direnç, gate ile source arasına 10k pull-down. Pull-down olmazsa Pi açılırken lambalar yanıp söner. 4 A’de IRLZ44N soğutucusuz rahat çalışır, Pi’nin eksisi ile akünün eksisini birleştirmeyi unutma.
Zamanlama için Hermetry’de Kurallar kartını kullan:
- Ne zaman: Gün doğumu veya gün batımı, gün batımı, ofset -15 dakika
- Sonra: Komut gönder, cihaz Pi, komut
light.set, parametreon: true - İkinci bir kural: gün doğumu,
on: false
Komutu cihaz profilinin Commands kataloğuna eklemen lazım. Bir de yerin konumu girilmiş olmalı, yoksa kart kaydetmiyor: cihazın üstündeki en yakın varlığın konumu kullanılıyor. Ayrıntılar: Kurallar kartı: tetikleyiciler.
Pi tarafında v1/rpc/req/+ konusuna abone ol, light.set gelince pini sür, cevabı v1/rpc/res/<id> ile dön. Mevsim derdi de böylece kalmaz.
Translated from Türkçe by AI ·
At 2 km Zigbee won’t work then, it struggles to cover even a few hundred meters in open areas. You’d need a repeater in between, and the battery will be a headache too.
2 km’de Zigbee de olmaz o zaman, açık alanda bile birkaç yüz metreyi zor geçer. Arada röle koymak lazım, pille de uğraştırır.
Çok net oldu, teşekkürler Esra Hanım. Vanayı Opening’e bağladım, SP için set point kartı koydum, Kp’yi ekrandan kaldırdım. Komutu ilk başta Privileged yapmıştım, panodan “This command cannot be sent from a board” hatası aldım, Basic’e çektik ama kartı sadece vardiya şefleri görsün diye ayrı bir panoya koyduk.
Akış yönü olsa diğer oklar gibi yatay olurdu diye düşündüm. Hande Hanım’ın dediği daha mantıklı geliyor.