Which account did you give the camera?
Dangerous settings are Owner only. Am I right that an API key can never write those then?
Welcome. Is the region per organisation or per person? Some of our people sit in Canada and some in Europe, and I’d rather not split us in two.
That is the answer I wanted for our vendor questionnaire. Two follow-ups from the same form: where do backups go, and can your own operators get into a node?
Clean session false won’t help on Hermetry anyway. I’m fairly sure the docs say it’s served as a clean session.
Moved both boards to SPI0 with CE0/CE1, removed the two overlays, three days without a crash and the readings match the old ones within 0.1 °C. Thanks Aoife. @Keisha the offline alarm wouldn’t help there since the Pi is still online. A threshold rule can’t see a missing key either, as far as I know. We’re looking at a flow watchdog for that.
enable_uart=1 (serial console is on, someone uses it for headless recovery), dtparam=i2c_arm=on, and the two SPI lines.
HC-12 modules are an Si4463 with a small MCU on top that gives you a plain serial port. If you don’t need anything fancy, that’s the lazy route.
Bottom layer under the trace was empty, I had routed the battery line through there. Rev B: CPWG at 50 ohm, via fence, ground solid. Now -100 dBm and SNR +6 at the same spot. Thanks Laura.
868, same one I use on the dev board.
That table is what I was missing. Left the profile at the defaults. After a week most meters sit at DR5 and four basement ones at DR2, all visible in lora.dr. Thanks Ciaran.
Good, that’s the same setup we use for a few signal lamps. Three pieces:
- Device profile of the relay, Commands tab: add a command
light.set, tier Basic, one parameteronof type Yes / no. Tier matters, because an API key can only send methods that are in the profile’s catalog. - Firmware: subscribe to
v1/rpc/req/+, switch GPIO12 (the relay on the Basic R2), answer on the same id, and report the new state.
void onMsg(char* topic, byte* p, unsigned int n) {
// topic: v1/rpc/req/42
String id = String(topic).substring(11);
StaticJsonDocument<128> d; deserializeJson(d, p, n);
bool on = d["params"]["on"];
digitalWrite(12, on ? HIGH : LOW);
mqtt.publish(("v1/rpc/res/" + id).c_str(), "{"ok":true}");
mqtt.publish("v1/telemetry", on ? "{"relay":1}" : "{"relay":0}");
}
- Your script: an API key from API Keys (Developer menu) with only what it needs. The send route wants
iot_rpc.readplus the tier’s permission, so tick those two and nothing else, fill the IP allowlist with the lab PC’s address and keep the 90-day expiry.
import requests
r = requests.post(
f"https://{HOST}/tenant/{TENANT}/api/iot/devices/{DEVICE}/rpc",
headers={"Authorization": f"Bearer {KEY}"},
json={"method": "light.set", "params": {"on": True}, "timeoutMs": 10000},
)
print(r.status_code, r.json()["rpc"]["status"])
A two-way command with a timeout of 30 s or less waits and comes back 200 with SUCCESSFUL. Reference: Commands API
The ESP8266 does TLS, but memory is tight; use BearSSL with smaller buffers if the connect fails.
Worth leaving a comment above every line you add to config.txt with the date and why. Saves the next person.
Exactly what I needed for the meeting. I explained the trapped air and stuck spool cases with Laura’s wording and management stopped asking about removing a part. I also told them no cloud product, Hermetry Safe included, takes over the safety chain, it stays hardwired. We added the aux contact and the dump valve pressure switch as telemetry, plus an alarm when the e-stop is active and the dump has not vented within 5 seconds. Tested it on Friday with the engineer present.