Reply To: STM32 with a MAX3485 gets my own echo and loses the start of the Modbus reply

That was it. The HAL_Delay(5) was something I’d added while guessing, removing it and waiting on TC gives me all 9 bytes and the CRC checks out every time. No more echo either. Moving to idle line DMA next like Aoife suggested.