thompsonplc
@lthompson · Joined May 2025
Automation engineer · pharma · 14 years in the field
- Topics
- 7
- Replies
- 65
- Points
- 0
Recent activity
-
Replied to Eight meters on 30 m of RS-485 at 9600 baud: do I need termination, or is it something else?
Tyler, please don't, eight 120 ohm resistors in parallel load the line to 15 ohm and nothing will talk.Owen: at 9600 baud a bit…
-
Replied to Switching Wi-Fi bulbs from a board Switch through my Pi, no vendor app
And whoever uses the board needs the permission to run widget commands, or the Switch just says no. Caught a colleague out at work.
-
Replied to 2.0.1: sign-in links by e-mail, remember me, and passkeys you can rename
Makes sense. Passkeys it is then.
-
Replied to 2.0.1: sign-in links by e-mail, remember me, and passkeys you can rename
Our owner switched on "Require two-step verification for every member" last month. Does the e-mail link get people around that, or do they still…
-
Replied to ESP8266 intercom buzzer detector: how do I get a ping on my phone?
Hardware first. Use an optocoupler: bridge rectifier (or a PC817 with a reverse diode across the LED), 1 kΩ series resistor, 10 µF across…
-
Replied to 2.0.1: dashboard cards can open a page or run an action when clicked
Row click on a table, Set board parameters with the clicked row, and the chart beside it follows the row. Five minutes. Good.
-
Replied to 2.0.1: custom access groups, and admins can rename the workspace
Can a group take a permission away? We have Users who should see devices and alarms but never acknowledge anything.
-
Replied to How do I draw the terminal strips in the wiring diagram for a gateway panel?
Add a revision block too, the second version always comes.