Warehouse temperature mapping is a documented study that measures temperature at many points across a pharmaceutical store to find its hot and cold spots and decide where products may sit. WHO guidance places loggers on a grid every 5 to 10 metres, at several heights, recording every 1 to 15 minutes, typically for at least seven days.
I work from the WHO technical supplement Temperature mapping of storage areas. It runs in four stages: an approved protocol, the mapping, a report, and the actions the report calls for.
How many sensors does warehouse temperature mapping need?
Enough to cover the floor on a grid and the full height at each grid point. WHO suggests a logger every 5 to 10 metres along the length and width, adjusted for alcoves, racking that blocks airflow, and where product is actually stored.
With a ceiling of 3.6 metres or less, WHO puts three loggers at each point, for example at floor level, 1.2 metres and 3.0 metres. Its example for a 6-metre store uses four: 0.3, 1.8, 3.6 and 5.4 metres. On a floor 40 by 20 metres with a point every 10 metres, I count 15 grid points if the outer rows sit along the walls, so 60 loggers at four heights.
How long should a temperature mapping study run?
For a warehouse, WHO says typically at least seven consecutive days, five working days and two weekend days. Cold rooms and freezer rooms get 24 to 72 hours, or longer if justified.
All loggers record at the same interval, typically 1 to 15 minutes, from the same start time, or the readings cannot be correlated. A store affected by the seasons may need two studies, one in the warmest season and one in the coldest.
How does sensor calibration affect mapping results?
Calibration decides how far apart two readings must be before the difference means anything. WHO asks for a NIST-traceable three-point calibration, valid within the current year, with an error of no more than ±0.5 °C at each point.
At ±0.5 °C each, two loggers can disagree by a full degree while both are in tolerance, so a hot spot reading 7.6 °C in a 2 to 8 °C room could be over the limit. WHO asks the analyst to account for the reading errors the device maker specifies. Record each logger’s serial number against its location, so every reading traces back to its certificate.
What do you do with the hot and cold spots?
You use them to decide where product may go and where the routine monitoring sensors belong. In WHO’s terms, a hot spot is the highest temperature recorded during the study that is still inside the range, a cold spot the lowest.
Compare each logger’s mean over the study as well as its extremes, since a location that runs consistently cooler shows up in the means. The report then sets the actions: a drawing of where products may be stored, zones kept free near cooling coils or heat sources, moved sensors, adjusted air outlets. I treat the downloaded data like any monitoring record.
Hermetry connects field devices to live dashboards, rules and alerts: IoT telemetry and SCADA in one platform. Each monitoring sensor the study settles on can be placed on its room in Hermetry, and a device placed on a room counts for its floor, building and site, so its status and open alarms show at every level above it. Hermetry keeps the maximum of every numeric reading per hour, so a chart of each monitoring sensor’s hourly maximums shows whether a hot spot stays put.
For zone-by-zone monitoring after the study, see warehouse temperature, humidity and door monitoring and the pharma industry page.
Frequently asked questions
Should a warehouse be temperature mapped empty or full?
Both, for a new store. WHO says new temperature-controlled storage areas must be mapped before they are commissioned, showing the air temperature profile when empty and in a normal loaded condition. An existing store, for example after alterations, can be mapped with products in it.
Can a temperature mapping study include door openings?
Yes. WHO says the protocol should state it and define how often and how long the door opens; temperature should stay within limits except for at most 30 minutes after an opening. Without automatic door logging, keep an access log during the study.
How often should a warehouse be re-mapped?
WHO gives every three years as an example, depending on the monitoring strategy, and asks for mapping after significant changes: heavier loading, altered air circulation, or refrigeration changes such as a new set point. Unexplained variability in monitoring records can also justify a remap.