Soil moisture sensor calibration turns a probe’s raw reading into volumetric water content for your own soil, and then into an irrigation trigger. Take a dry and a wet reference reading in that soil, map the raw values linearly between them, and irrigate when the water content falls to the level your soil and crop allow.
I build automation for farms. A raw count of 2,100 from a soil probe says nothing on its own; it becomes useful once it is tied to the water content of the field’s own soil.
What does a raw soil moisture reading mean?
A raw reading is the output of the sensor’s circuit, a voltage or count, not a water content. The soil itself affects it, so relate it to water content in each soil with a two-point calibration:
- Install the probe at its final depth and let the soil settle around it.
- Record the reading when the soil is at its driest in normal operation, and take a soil sample next to the probe.
- Do the same a day after a full irrigation has drained.
- Have both samples weighed, oven-dried and weighed again, and convert the lost water to volumetric water content with the soil’s bulk density.
- Map the raw readings linearly between those two water contents.
A third sample in mid-season shows whether the straight line holds where you actually irrigate.
Hermetry connects field devices to live dashboards, rules and alerts: IoT telemetry and SCADA in one platform. Its LoRaWAN codec library includes codecs for soil moisture, temperature, conductivity and pH sensors, and a flow’s Scale block maps a number linearly from one range to another before it is stored. Set the input range to the probe’s two calibration readings and the output range to the water contents you measured; the default mode clamps results to that range, and mode free leaves them unclamped. The block is described in the data transform blocks reference.
What is a good soil moisture reading for irrigation?
There is no single good number; the trigger depends on the soil’s field capacity and wilting point and on the crop. FAO Irrigation and Drainage Paper 56 defines total available water as the difference between the two over the root depth, and readily available water as a fraction p of it, with 0.50 commonly used for many crops.
That gives a trigger in volumetric water content: field capacity minus p times the difference. With the approximate soil values FAO uses in its worked example and p = 0.50:
| Soil | Field capacity | Wilting point | Irrigate at about |
|---|---|---|---|
| Loamy sand | 0.15 m³/m³ | 0.06 m³/m³ | 0.105 m³/m³ |
| Silty clay | 0.35 m³/m³ | 0.23 m³/m³ | 0.29 m³/m³ |
A reading of 0.20 m³/m³ is above field capacity in that sand and below the wilting point in that clay. FAO also gives p values from 0.30 for shallow-rooted plants at high water use to 0.70 for deep-rooted plants at low water use, so set p per crop.
Why do soil moisture sensors corrode?
Resistive probes corrode because they pass current through wet soil between two bare metal electrodes, and with direct current the electrodes take part in electrolysis. The readings drift as the metal wears.
Powering the probe only for the moment of a reading slows this down. A capacitive probe avoids it, because its electrodes sit under a coating and no direct current passes through the soil.
Capacitive or resistive soil moisture sensor?
For anything that runs a pump, I would choose capacitive. A capacitive probe measures the soil’s dielectric permittivity, which rises with water content because water’s permittivity is far higher than that of soil minerals or air. A resistive probe measures conduction, so fertiliser salts move its reading as well. Both need the field calibration above. A single bad reading should not start a pump either, which is the subject of sensor spike filtering. For a whole irrigation setup, see monitoring for agriculture and soil moisture based irrigation for farms and orchards.
Frequently asked questions
How deep should soil moisture probes go?
Inside the root zone, ideally at two depths so you can see water arrive and drain. FAO Paper 56 uses rooting depths of about 0.4 m for onion, 0.8 m for tomato and 1.2 m for maize in its worked example, so the depths follow the crop, not a fixed rule.
How often should a soil moisture sensor report?
I would start with every 15 to 30 minutes. Soil water changes slowly between irrigations, and faster readings mostly cost battery on a field sensor. During irrigation a shorter interval shows when water reaches the lower probe, if the sensor allows it.
Do I need to recalibrate a soil moisture sensor?
Check the calibration whenever a probe is moved, the soil around it is worked, or a new season starts. Resistive probes need it more often, because corrosion changes their readings over time. A fresh soil sample next to the probe, compared with its reading, shows whether the line still holds.