Minimum night flow leak detection: finding bursts in a water network from flow and pressure

Utilities find leaks by metering whole zones and reading them at night. District metered areas, the night flow calculation, the night-day factor and the pressure drop of a burst.

Minimum night flow (MNF) leak detection meters all water entering a closed zone of the network, a district metered area, and watches the lowest flow of the night, when customers use least. Subtract an estimate of customer night use and the rest is night leakage; a sudden step up, with a pressure drop, points to a new burst.

A single flow sensor tells you what one pipe carries. To find leaks in a network, water utilities meter whole zones and read them at night, when real use is lowest.

What is a district metered area?

A district metered area (DMA) is a zone of the network closed off by shut boundary valves, with a meter on every pipe that feeds it. The EU Good Practices on Leakage Management describe meters with telemetry data loggers at these points, so the utility can monitor the zone’s consumption continuously and estimate leakage from it.

The numbers hold only if every inflow and outflow has a meter and the boundary valves stay shut. One valve left open after a repair feeds the zone from its neighbour, and the night flow no longer describes the zone.

How do you calculate minimum night flow?

Take the zone’s net inflow, find its lowest average over the same night window every day, and subtract the estimated night use of customers. What remains is night leakage, a rate in cubic metres per hour.

  1. Log the inflow, minus any flow out to neighbouring zones, every few minutes.
  2. Average it over fixed periods, 15 minutes or an hour, and take the lowest period of the night. How much an average can hide is covered in downsampling time series data.
  3. Subtract customer night use: households, plus any large users known to run at night.
  4. Plot the result every day. A slow rise means leaks building up; a sudden step points to a new burst or a change in the zone.

Do not multiply night leakage by 24 to get a daily figure. Leak flow follows pressure, and pressure changes over the day, so the EU guidance converts it with a night-day factor that ranges from 15 to 30 or more hours per day, depending on how much pressure varies in the zone.

Hermetry connects field devices to live dashboards, rules and alerts: IoT telemetry and SCADA in one platform. It keeps aggregates and rollups of every numeric key per minute, hour and day, with the sum, count, minimum, maximum and last value of each bucket. A chart window from 7 days to about 416 days reads the hour rollups, so a DMA inflow charted with the avg aggregate shows each night’s lowest hourly average without exporting data. Buckets are aligned to UTC, so pick the hours that match your local night.

How does pressure data help find bursts?

Pressure tells you whether a change in night flow is a burst and how hard each leak runs. A burst draws more water through the mains, friction losses rise, and pressure in the zone drops at the moment the night flow steps up.

Leak flow also depends on pressure. Under the FAVAD concept in the EU guidance, leak flow varies with average zone pressure raised to a power N1, about 0.5 to 1.5 depending on the leak type, so a 10 % pressure cut reduces leak flow by roughly 5 % to 15 %. I compare night flows at similar pressure, measured at a point that represents the zone’s average, which the guidance calls the Average Zone Point. A flow step with no pressure drop is worth checking against a boundary valve or a new night user before a crew goes out. For a full design, see the pressure and night flow watch for a water distribution network.

Frequently asked questions

How big should a district metered area be?

Small enough to see the leaks you care about. In the EU case studies, DMAs range from about 5,000 to fewer than 100 service connections. An Austrian case found that below about 3,000 connections a single new mains burst becomes easier to spot in continuous night flow, and a single service leak at about 1,000. Background leakage showed at about 400 or fewer in Odense, Denmark.

Why read the flow at night instead of over the whole day?

At night customer use is at its lowest, so leakage makes up most of the flow. The EU guidance notes that leakage as a share of system input can fall from 90 % to 10 % over the few hours between the minimum night flow and the morning demand peak.

Can a single building use the same idea?

Yes, on a smaller scale. Read the main meter in the quietest hour, when nothing should run. If the flow never drops to zero night after night, something is leaking or running that nobody switched on, and it is worth walking the building before the next bill.