Reply To: Reading the partition table of ESP32s already in the field before we turn on OTA

Done. 9 of the contractor’s 12 came back with a single 3 MB app0, so no OTA on those without a visit. The other 3 and all of ours have app0/app1 at 1.25 MB each, which is tight against our 1.4 MB build, so I’m switching our table to the minimal SPIFFS one with 1.9 MB slots before we go further. Good thing we checked first.