New: the AI firewall watches the whole platform and explains each incident in plain words. See how it works

Reply To: After a power outage, 60 ESP32s enter an endless reconnection loop

Translated from Türkçe by AI ·

+1 for jitter. We also had a field case where 40 sensors trying to connect at the same time caused some of them to hit address blocking; it was resolved with a random delay.

Sahadan selamlar.
♥ 2