New: the AI firewall watches the whole platform and explains each incident in plain words. See how it works

Machine vibration monitoring: what to measure and what to send

Velocity or acceleration, RMS or peak, waveform or summary: what a vibration sensor should measure and what it should send over a remote link.

Machine vibration monitoring measures how a machine’s housing moves, as displacement, velocity or acceleration, and tracks that level over time so a developing fault shows before the machine stops. For remote monitoring, compute summary values at the sensor, such as RMS velocity and peak acceleration, and send those every few minutes rather than the raw waveform.

I write the software that receives this data. The decisions that matter come after an accelerometer’s output becomes a number: which number to send, how often, and what stays at the machine.

Vibration velocity or acceleration for machine monitoring?

Both describe the same motion; the right one depends on the frequencies you care about. The U.S. Department of Energy’s O&M Best Practices Guide says the unit that best shows machine condition depends on the machine’s speed and design.

MeasureWhat it isWhat it makes stand out
DisplacementDistance from one extreme of travel to the other (peak-to-peak)Low frequencies
VelocityHow fast the surface moves as it oscillatesThe middle of the range
AccelerationRate of change of velocityHigh frequencies

The reason is arithmetic. For a vibration at frequency f, velocity is displacement times 2πf, and acceleration is velocity times 2πf. Two components with the same velocity, one at 100 Hz and one at 1,000 Hz, differ tenfold in acceleration. I report velocity as the overall level and keep acceleration for the high-frequency end.

What should a vibration sensor send, and how often?

Send a handful of summary values per interval, plus the machine’s running state, and keep the waveform at the sensor. One axis sampled 10,000 times a second at 2 bytes per sample is 20 kB a second, about 1.7 GB a day of data. No cellular or low-power link should carry that for a value you look at weekly.

  1. RMS velocity: the overall level, the number you trend.
  2. Peak acceleration: short impacts barely move an RMS value but show in the peak.
  3. Crest factor (peak divided by RMS): about 1.41 for a pure sine, higher when impacts ride on the signal.
  4. Running state or speed, so readings from a stopped machine do not drag the trend down; the same signal feeds machine downtime tracking.

Every one to ten minutes is enough for a trend. Keep the peak when you roll the data up later, because an hourly average flattens it, as Sema showed in what an hourly average hides.

Can FFT detect machine faults?

Yes, a spectrum from a fast Fourier transform (FFT) can point to the part causing the vibration, if someone reads it. The DOE guide describes signature analysis that separates the vibration by frequency, so a person who knows the machine’s design can trace a problem to a component. Its list of faults includes unbalance, misalignment, looseness, rolling element bearing problems, gear problems and belt drive problems, and it notes that the analysis needs highly trained people.

A spectrum needs a sample rate above twice the highest frequency you want to see, so compute it at the sensor or a gateway and send it on request, or when the RMS crosses a level.

How do you measure bearing temperature?

Put a contact temperature sensor on the bearing housing, as close to the bearing as the housing allows, and trend it against the ambient temperature. The DOE guide notes that trended infrared scans of single bearings give a useful indicator of wear and of the eventual need for replacement.

Ambient matters because a bearing reads warmer on a hot afternoon with nothing wrong; the DOE guide likewise trends the difference between a drive belt’s temperature and ambient. A rising difference at the same load is worth a look, and detecting outliers in sensor data helps separate it from noise. For a mining example, see conveyor, crusher and ventilation fan monitoring in mining.

Frequently asked questions

What vibration level is too high for a machine?

There is no single number. The DOE guide says it is impossible to establish absolute vibration limits, and that severity charts are for judging machines already in service, as a starting point, rather than acceptance criteria for new or rebuilt ones. Record a baseline for each machine in a known good state, at the same speed and load, and set action levels from it.

Where should a vibration sensor be mounted?

On the bearing housing, rigidly, and at the same point every time. The DOE guide describes transducers that are either permanently mounted or attached at the monitoring location for each round of data collection. A sensor that moves between readings changes the reading.

Is a vibration sensor enough without temperature?

Either one on its own misses things. Vibration analysis can trace a fault to a component, while trended bearing temperature, as the DOE guide notes for infrared scans, indicates wear and the eventual need for replacement. Sending both from the same housing costs little extra data.

Share

See your field data live this week

Start a trial in your region with your first devices, or book a demo and bring your own use case.