Cellular signal at remote sites: antennas, modem power and dropouts

A site checklist for cellular links: read the CSQ scale properly, take the antenna out of the metal cabinet, size the supply for transmit peaks, and alarm when a site goes quiet.

Cellular signal at a remote site depends on three things you control: where the antenna sits, how well the modem is powered, and whether you read the signal figures correctly. Put the antenna outside any metal cabinet, size the supply for transmit peaks rather than the average, and alarm on silence so a dropout shows up before anyone complains.

When one of my unmanned sites goes quiet, I check the antenna, the supply and the alarm setup before I blame the network operator.

What is a good CSQ or RSSI value for a cellular modem?

A good value is one you measured with the cabinet closed and that stays steady over days. The standard defines the scale and sets no pass mark. The AT+CSQ command in 3GPP TS 27.007 returns a received signal strength indication (RSSI) from 0 to 31, plus a bit error rate.

CSQ valueReceived signal strength
0-113 dBm or less
1-111 dBm
2 to 30-109 to -53 dBm
31-51 dBm or greater
99Not known or not detectable

Between 2 and 30, each step is 2 dB. On an LTE (4G) cell, the AT+CESQ command reports reference signal received power (RSRP) and quality (RSRQ). I record the figures at commissioning and trend them, because one reading is a snapshot and the trend shows a site drifting towards the edge of coverage.

Does an antenna work inside an enclosure?

Inside a plastic enclosure it usually works; inside a closed metal cabinet it works badly, because the metal shields the antenna from the radio waves. Mount the antenna on the outside of the cabinet, or on the mast with a short cable, since coaxial cable loses signal with every metre.

Measure with the door shut, because that is how the modem spends the year.

Why does a cellular modem keep rebooting?

When a modem reboots in a loop, check the supply first, because the modem may run short of current each time it transmits. A 2G modem transmits in bursts. GSM divides time into TDMA frames of eight timeslots, about 4.62 ms per frame (3GPP TS 45.002), and a power class 4 modem in the 900 MHz band transmits at up to 2 W (3GPP TS 45.005).

GSM power control keeps transmit power as low as the link quality allows (3GPP TS 45.008), so on a weak site the network orders the modem up towards its maximum. A supply sized for the average current sags during each burst, and the modem drops out, restarts and drops out again.

  1. Size the supply and the wiring for the peak transmit current in the modem’s datasheet, not the average.
  2. Measure the voltage at the modem’s terminals while it transmits.
  3. Improve the antenna: a stronger signal lowers the power the network asks for.

How do you know when a remote site goes offline?

Alarm on silence, with a delay longer than a normal reconnect. Mobile links drop and reconnect, and an alarm that fires on every short drop soon gets muted; Sema covers the delay choice in alerting on missing data.

Hermetry connects field devices to live dashboards, rules and alerts: IoT telemetry and SCADA in one platform. Its Device offline rule sits on the device profile and opens an alarm when a device stops talking. Open after can be set from 10 to 604,800 seconds (default 600); for a device on a live connection over a mobile network, which may drop its session briefly, the docs suggest 300 to 900 seconds. The alarm clears by itself when the device comes back.

For the power side of a silent site, see remote site UPS monitoring and UPS, generator and climate monitoring at unmanned sites.

Frequently asked questions

What does a CSQ of 99 mean?

The modem has no figure to report: 3GPP TS 27.007 defines 99 as not known or not detectable, for both the signal strength and the bit error rate. Check that the SIM is seated, that the antenna cable is connected at both ends, and that the modem has registered on the network.

Which fields of AT+CESQ apply to a 4G connection?

On an LTE cell, read RSRP and RSRQ. 3GPP TS 27.007 encodes RSRP from below -140 dBm up to -44 dBm and above, and RSRQ from below -19.5 dB up to -3 dB and above. Fields for other radio types read 99 or 255 when the serving cell is not of that type.

Should a modem share a power supply with the sensors?

It can, if the supply is sized for the modem’s transmit peak plus everything else on the rail. Otherwise the sensors and controller see the same dip during each burst, and a weak cellular link shows up as sensor resets. A separate regulator for the modem keeps the two apart.

Share

See your field data live this week

Start a trial in your region with your first devices, or book a demo and bring your own use case.