fw_owen
@owen_t42 · Nisan 2026 tarihinde katıldı
Embedded developer · agriculture
- Konular
- 6
- Yanıtlar
- 20
- Puan
- 0
Oluşturulan forum yanıtları
Yapay zekâ tarafından English dilinden çevrildi ·
Yani rolü User olan tek tasarımcımız için bir grup oluşturup buna designs.write iznini mi işaretlemeliyim? Yoksa write izni her durumda Admin gerektirir mi?
So for our one designer who is a User, I’d make a group and tick designs.write for it? Or does write need Admin no matter what?
Yapay zekâ tarafından English dilinden çevrildi ·
Bugün ota.rollout.paused olayını on-call webhook’umuza bağladım. Sabah saat 2’de yapılan dalga duraklatmalarının bildirilmesi tam da istediğim şey.
Wired ota.rollout.paused into our on-call webhook today. Wave pauses at 2 in the morning are exactly what I want to hear about.
Yapay zekâ tarafından English dilinden çevrildi ·
En üstteki işaretçilerinizden ikisi neredeyse birbirinin üzerinde. Üst üste geldiklerinde gruplanıyorlar mı?
Two of your markers near the top are almost on top of each other. Do they group when they overlap?
I always assumed WROOM was “Wireless ROOM” or something. Never checked.
Yapay zekâ tarafından English dilinden çevrildi ·
Kartta yaklaşık 4,63 V’de devreye giren bir gerilim denetleyicisi var ve yazılım bunu kilitliyor. Bunu vcgencmd get_throttled ile okuyabilirsiniz.
There’s a voltage supervisor on the board that trips at roughly 4.63 V and the firmware latches it. You read it with vcgencmd get_throttled.
AfcAutoOn on, AfcBw at 41.7 kHz. This week had three mornings at -1 °C and no dropouts. The FEI chart is a nice touch, one probe swings 13 kHz, it gets a TCXO board.
Yapay zekâ tarafından English dilinden çevrildi ·
Yönlendirici A, çiftlik müdürüyle telefonda konuşularak çözüldü; panel ilk denemede açıldı ve Modbus zaman aşımını masamdan düzelttim. Yönlendirici B dün gece kendiliğinden güncellendi, ardından panel orada da çalıştı. LTE üzerindeydi ve 50 MB uyarısı çıktı, oturum yaklaşık 6 MB kullandı.
Router A done via phone call with the farm manager, panel opened on the first try and I fixed the Modbus timeout from my desk. Router B updated last night on its own, then the panel worked too. It was on LTE and the 50 MB prompt came up, the session used about 6.
Yapay zekâ tarafından English dilinden çevrildi ·
İki haftanın sonuçları geldi. Keepalive 300 (taşıyıcımız buna sorun çıkarmıyor, Log sekmesinde zaman aşımı yok), 3’lü gruplar halinde gönderim, öznitelikler yalnızca değiştiğinde. SIM başına aylık tahmini ~9 MB, önceki 25 MB’dan düştü. Sürpriz, öznitelik trafiğiydi: firmware’imiz her okumayla birlikte lan.ip ve cell.rssi değerlerini öznitelik olarak yayınlıyordu. rssi’yi bunun yerine her 15 dakikada bir telemetri olarak taşıdık. Kevin, teşekkürler; bu ölçümler bana bir haftalık iş kazandırdı.
Numbers are in after two weeks. Keepalive 300 (our carrier is fine with it, no timeouts in the Log tab), batches of 3, attributes only on change. Projected ~9 MB per SIM per month, down from 25. The attribute chatter was the surprise: our firmware was publishing lan.ip and cell.rssi as attributes with every reading. Moved rssi into telemetry every 15 minutes instead. Thanks Kevin, those measurements saved me a week.
We track tractors and handheld scanners in large sheds, so I’ve been through both parts.
Positioning: UWB two-way ranging. Fix 4-8 anchors on walls and columns (more in aisles with racking), put a tag on each cart (Qorvo DWM1001/DWM3000 modules are the usual starting point). The tag ranges to the anchors and computes x, y in metres in your own coordinate frame. 10-30 cm accuracy in line of sight. Racks of metal parts will cost you some of that.
The dashboard part is easier than people think. A Map card has an Image (floor plan) mode: you give it the floor plan picture and its width/height in pixels, and then the latitude and longitude columns hold y and x in pixels from the top-left corner. So convert metres to pixels on the cart (or in the gateway) and send them as two keys:
{"pos_x_px": 812, "pos_y_px": 377, "batt_pct": 74, "job": "B12"}
In the card set Latitude column to pos_y_px and Longitude column to pos_x_px, colour markers from a status column (idle, busy, fault), and add tooltip fields for battery and job. Routes can be drawn and replayed too if you want “where did cart 7 go this morning”.
Megan’s question matters for limits. One message per cart per second is 86,400 a day each, so put all the cart’s values in the same message. The default per-device limit is 10 messages a second, so you’re fine there, but look at your monthly message quota before you go to 50 carts. Map cards
Struct with scaled int fixed it. Temperature has been clean since yesterday afternoon, no gaps on the chart. The evaluation order thing was news to me.
Yapay zekâ tarafından English dilinden çevrildi ·
İki test cihazında ve bir sahadaki cihazda çalışır hale getirdim. Flash belleğin üst yarısını ve 16 KB’lık bir bootloader’ı kullandım. İlk deneme başarısız oldu; paketteki fw_title değerini “irr_stm32” olarak ayarlamıştım, ESP32 ise bir tire arıyordu, bu yüzden cihaz Queued durumunda takılı kaldı. Adı doğru şekilde verince işlem UPDATED durumuna geçti ve yeni current_fw_version değeri göründü.
Got it working on two bench units and one in the field. I used the upper half of flash plus a 16 KB bootloader. First try failed because I set fw_title on the package to “irr_stm32” and the ESP32 checked for a dash, so it just sat in Queued. Named it properly and it went through to UPDATED with the new current_fw_version.
Yapay zekâ tarafından English dilinden çevrildi ·
Tam da ihtiyacım olan şey buydu. Ona şunu söyledim: IoT katmanımız var; bizim için “4.0” kısmı varlık ağacı ile pivotlar üzerindeki otomatik eylemler olur, MES benzeri her şeyi ise Forge’un neleri kapsadığını öğrendikten sonra ayrıca değerlendiririz. Bundan memnun kaldı ve kuzey çiftlik için Sites & Assets bölümünü geliştirmek üzere bir ticket aldım. Teşekkürler Maria.
This is exactly what I needed. Told him: we have the IoT layer, the “4.0” part for us would be the asset tree plus automatic actions on the pivots, and anything MES-like we look at separately once I know what Forge covers. He was happy with that, and I got a ticket to build out Sites & Assets for the north farm. Thanks Maria.
Yapay zekâ tarafından English dilinden çevrildi ·
Haha, toplantı için ihtiyacım olan kelime muhtemelen “tesisat”. Ama “peki bunu 4.0 yapan ne olacak” diye soracak ve bunun cevabı hâlâ bende yok.
Ha, “plumbing” is probably the word I need for the meeting. But he will ask “so what would make it 4.0” and I still don’t have that.
Once it joins you’ll see your bytes but no values until you give the profile a codec. Plan your payload layout before you write the firmware.
master side, sorry, should have included it:
Wire.requestFrom(8, 9);
m1 = (Wire.read() << 8) | Wire.read();
m2 = (Wire.read() << 8) | Wire.read();
Wire.read(); // the old byte
for (int i = 0; i < 4; i++) ((byte*)&t)[i] = Wire.read();