Actividad reciente
-
Respondidos Saludos de un ingeniero de automatización de petróleo y gas
Hello from another field person. Watch for condensation in shelters like that, it settles on bare breakout boards overnight when the temperature drops. Conformal…
-
Short version from someone who has sat through too many of those slides: IoT is the plumbing (things with sensors that talk to a…
-
Built the P+N version on one station to test: battery current in sleep dropped by about 0.1 mA, and the reading is the same…
-
100k top, 22k bottom. At 12.6 V I get about 2.27 V on the pin, raw around 2700.
-
Two connected problems on our soil moisture stations (farm, 9 stations, each with a 12 V 7 Ah lead-acid battery and a 10 W…
-
Respondidos Blindaje del cable RS-485: ¿tierra, 0 V de la alimentación o ambos extremos?
Do you also have a separate 0 V / common wire between the meters and the gateway, or just A and B?
-
Respondidos Dibujo de nuestro sistema de aire comprimido: dónde va la válvula de retención y cómo mostrarla
Careful there: when compressor 2 is off, the receiver pressure pushes back into its discharge line. Most screw compressors do have a minimum pressure/check…
-
We went with an AODD pump in the pit, stainless with flap valves, and a dampener on the line. The separator is happy. On…