tyler22
@walker-t · Se unió el junio 2025
Data analyst · manufacturing
- Temas
- 3
- Respuestas
- 15
- Puntos
- 0
Actividad reciente
-
Respondidos Leer el registro de auditoría: quién hizo qué y comprobar que nadie lo editó
Those feature.access.checked rows would bury everything on our org. Can I hide them from the list?
-
Respondidos Eight meters on 30 m of RS-485 at 9600 baud: do I need termination, or is it something else?
Fair, I mixed up two different setups. Bias it is.
-
Where do I see suppressed ones for alarm notifications? We don't send those from a flow.
-
Respondidos Eight meters on 30 m of RS-485 at 9600 baud: do I need termination, or is it something else?
Always terminate, put 120 ohm at every meter.
-
Respondidos Rastreador de remolques en un NodeMCU: la tarjeta de mapa indica que no hay filas con coordenadas válidas
Is the GPS getting a fix? Indoors the NEO-6M can sit for minutes with 0 sats and TinyGPS will give you 0.0.
-
Respondidos Uno as an I2C slave sending floats to a Mega and taking commands back: values come out garbled
What Carlos said, here's the version I use for our line counters (an Uno doing the counting, a bigger board doing the network). Send…
-
Respondidos Hello from Sema, I look after dashboards
Welcome. Will remember the screenshot rule, I usually just say "the chart is weird".
-
Respondidos ¿Qué extremo del header del Pi Zero W es el pin 1? Mi DHT22 se calienta y no devuelve nada
Also if you're on the old Adafruit_DHT library, it's deprecated. The circuitpython one works on current Pi OS: adafruit-circuitpython-dht plus board.D4.