brian14
@russo-b · Se unió el diciembre 2025
IT and security admin · energy
- Temas
- 4
- Respuestas
- 7
- Puntos
- 0
Respuestas de foro creadas
Thanks, the explanation helped me write it up for my manager. Batched to one message every 2 minutes with 4 readings and keepalive 90 s first: no keepalive timeouts in a week. The yard AP on a bridge is approved for next month.
2.4 GHz, 20 MHz channels. The ESP32 can’t do 5 GHz anyway.
Traducido del English por IA ·
Preferiríamos enviar los eventos de alta severidad a nuestro SIEM en lugar de consultar la API. ¿Hay algún hook para eso?
We’d rather push high severity events into our SIEM than poll the API. Any hook for that?
SDN was floating. Tied it through the library pin and init succeeded on the first try. Sender at the tank, receiver on a second Pro Mini that passes lines to the Pi over USB, 900 m with RSSI around -95. Tank level is in Hermetry as tank.level_cm. Thanks Eric, and Maria for the reminder about power limits, I backed it off.
Traducido del English por IA ·
Solucionado. Se limpió el archivo interfaces, la configuración estática está en dhcpcd.conf con noipv4ll, y reinicié la Pi diez veces seguidas esta mañana; la pasarela se conectó en pocos segundos en todas las ocasiones. La pestaña Log ahora muestra una sola conexión limpia por arranque.
Fixed. Interfaces file cleaned, static config in dhcpcd.conf with noipv4ll, rebooted the Pi ten times in a row this morning and the gateway connected within a few seconds every time. The Log tab now shows one clean connect per boot.
Traducido del English por IA ·
Sí, ifdown indica interface eth0 not configured y ifup falla de la misma forma después.
Yes, ifdown says interface eth0 not configured and ifup fails the same way afterwards.
Kept the check valves (maintenance lead agreed with jessicathompson37). My compressor 2 pipe was drawn from the receiver, as you guessed. Redrew both from the compressors, now only the running one animates. Compressor symbols appeared after purchasing asked about the Process library, we had only the core set. Bypass added.