Plant manager, not a security person, but we lost a board out of a remote pump house last year and I had to clean up after it, so this is what we do now.

One credential per device, never shared. If two boards ever run the same token, the second login takes over the first one’s session and you spend a week chasing « flapping » devices. Tokens and the PSK go into NVS at the bench, like Aoife says, so the binary carries no secrets. Flash encryption on production boards once you’ve practised on a couple of spares.

On the Hermetry side, the profile has an Allowed networks field. Put the public address range your cabinet routers use in it. A token dumped from a stolen board is then refused from anywhere else (CONNACK 5, and the reason shows on the device’s Log tab). That one setting made our IT people much calmer.

When a board goes missing, revoke its credential (the API has DELETE on the device’s credentials) or just delete the device, and the old token stops working at once, with every open session cut. Admins also get a notice when a device logs in from a network it hasn’t used before, so watch for those.

For the PSK, put the sensors on their own SSID or VLAN on the router so a leaked PSK only gets you onto a network with nothing else on it.

Most of this is on the device credentials page.

Solution acceptée♥ 8

Traduit de English par IA ·

Nous avons acheté des trackers finis, donc désolé, nous ne pouvons pas aider. Nous suivons toutefois la discussion et réfléchissons à nos propres cartes.

♥ 0

Traduit de English par IA ·

En tant que personne qui valide les visites de dépôt : merci de vérifier ceci avant que le prochain lot ne soit flashé.

♥ 0

On Forge: there’s no doc page for it, so I can’t tell you whether it counts rejects or how you’d switch it on. What Lewis describes is what we do on our packing lines: counters as telemetry and a bar chart per hour with the increase aggregate. The supervisors look at it at shift change.

♥ 0

Traduit de English par IA ·

Dans ce cas l’image complète convient, je cesserais de m’inquiéter pour le delta. Nous avons envoyé une image de 1,6 Mo à environ 200 contrôleurs dans notre usine le printemps dernier. Le déploiement progressif est ce qui nous a rassurés.Pour l’affectation du paquet, choisissez Chaque appareil du profil et activez Envoyer par vagues. Le plan habituel consiste en un canari de 1 % (au moins un, au plus dix), puis 10 %, puis 50 %, puis le reste, avec 15 à 30 minutes d’attente entre chaque vague ; le déploiement se met automatiquement en pause si une vague dépasse 5 % d’échecs. Pour un hôtel, je modifierais les vagues : première vague de 3 chambres accessibles à pied, attendre quelques heures, puis 20, puis le reste pendant la nuit. Personne ne télécharge avant sa vague, donc le Wi-Fi ne voit que quelques appareils à la fois.Autres éléments qui nous ont aidés :

  • Testez d’abord avec des affectations Un seul appareil sur deux unités.
  • Le lien de téléchargement expire au bout de 15 minutes, mais l’appareil peut le redemander et reprendre avec une requête HTTP Range, donc une chambre instable n’est pas un drame.
  • Un appareil qui ne repasse pas sur la nouvelle version apparaît comme Revenu à l’ancienne version : c’est la preuve que votre retour arrière fonctionne.

Détails : Déploiement du firmware par vagues.

Solution acceptée♥ 4

We had this with old shields on a bottling line, two problems stacked on top of each other.

Forcing the switch port to 100/full is what killed traffic after you got a link. The W5100 still auto-negotiates. When the other side is forced, auto-negotiation can’t find out the duplex and falls back to half duplex. Switch on full, shield on half, and you get a duplex mismatch: link up, almost nothing passes. Put the ports back to auto, or force both ends (and you can’t force the W5100 from the Arduino library).

The original no-link problem is very often the reset on those clone shields. The W5100 comes out of reset before its supply is stable and its PHY sometimes never negotiates properly. The old switch was forgiving, the new one isn’t. Fix that worked for us:

// shield RESET pin wired to D8 with a jumper wire
pinMode(8, OUTPUT);
digitalWrite(8, LOW);
delay(50);
digitalWrite(8, HIGH);
delay(500);              // let the PHY settle
Ethernet.begin(mac, ip);

And if one still refuses, a cheap unmanaged 10/100 switch between the shield and the managed one ends the argument. Long term, W5500 shields don’t have this problem.

Solution acceptée♥ 5

Traduit de English par IA ·

Aisha a raison, et j’ajouterais quelques éléments issus de l’exploitation de passerelles Pi sur un atelier de production.
Achetez un splitter indiquant 802.3af/at et laissant le switch négocier, jamais un injecteur passif. Vérifiez la longueur du câblage : les longs cordons de brassage fins font chuter suffisamment la tension pour que le Pi throttle. Vous pouvez le voir directement sur le Pi :

$ vcgencmd get_throttled
throttled=0x50005      # bit 0 = under-voltage now, bit 16 = has happened since boot

J’enverrais cette valeur à Hermetry avec les relevés des sondes. La passerelle peut remonter sa propre télémétrie sur v1/telemetry comme un appareil normal, tandis que les sondes passent sur v1/gw/telemetry en tant qu’enfants. Une règle d’alarme sur le profil de la passerelle pour pi.undervolt == 1 vous indique alors que l’alimentation est limite avant que la carte SD ne soit corrompue.
Gardez à l’esprit que lorsque la passerelle passe hors ligne, tous ses enfants passent hors ligne avec elle. L’alarme de passerelle hors ligne est donc celle qui compte, et les alarmes hors ligne des enfants se déclencheront aussi, sauf si leur délai est plus long. Nous avons réglé la passerelle à 300 s et les enfants à 900 s. Le comportement des enfants est décrit ici : Passerelles et appareils derrière une passerelle.
Conservez aussi le tampon SQLite que vous utiliseriez de toute façon : un redémarrage du switch PoE pendant une mise à jour du firmware provoque une interruption de 2 minutes.

Solution acceptée♥ 4

Traduit de English par IA ·

Super. Nous avons ajouté une invite « Êtes-vous sûr ? » à la nôtre pour les lumières du quai, après que quelqu’un les a éteintes alors qu’un chauffeur faisait encore marche arrière.