rf_jessica
@jessicathompson37 · Membre depuis janvier 2026
Connectivity engineer · agriculture · 4 years in the field
- Sujets
- 2
- Réponses
- 9
- Points
- 0
Activité récente
-
Réponses à G’day from an oil and gas automation engineer
Hello from another field person. Watch for condensation in shelters like that, it settles on bare breakout boards overnight when the temperature drops. Conformal…
-
Short version from someone who has sat through too many of those slides: IoT is the plumbing (things with sensors that talk to a…
-
Built the P+N version on one station to test: battery current in sleep dropped by about 0.1 mA, and the reading is the same…
-
100k top, 22k bottom. At 12.6 V I get about 2.27 V on the pin, raw around 2700.
-
Two connected problems on our soil moisture stations (farm, 9 stations, each with a 12 V 7 Ah lead-acid battery and a 10 W…
-
Réponses à RS-485 cable shield: earth, 0 V of the supply, or both ends?
Do you also have a separate 0 V / common wire between the meters and the gateway, or just A and B?
-
Réponses à Drawing our compressed air system: where the check valve goes and how to show it
Careful there: when compressor 2 is off, the receiver pressure pushes back into its discharge line. Most screw compressors do have a minimum pressure/check…
-
We went with an AODD pump in the pit, stainless with flap valves, and a dampener on the line. The separator is happy. On…