reddysi
@nreddy · Se unió el noviembre 2025
System integrator · water and wastewater · 6 years in the field
- Temas
- 3
- Respuestas
- 14
- Puntos
- 0
Respuestas de foro creadas
Put hysteresis on the battery rule, something like below 20 with a margin of 5. Cold mornings make batteries dip and you’ll get an alarm every dawn otherwise.
Traducido del English por IA ·
Lo hice exactamente así para un cliente la semana pasada. La simulación mostró dos tarjetas como omitidas, ambas tarjetas de diagrama de proceso, porque la organización del cliente aún no tenía activado el módulo SCADA. Lo activé, eliminé la primera importación, volví a importar y las 14 tarjetas se transfirieron. Lee la simulación, te indica exactamente qué tarjeta es y por qué.
Did exactly this for a client last week. The dry run listed two cards as Skipped, both process diagram cards, because the client org didn’t have the SCADA module on yet. Turned it on, deleted the first import, imported again and all 14 cards came across. Read the dry run, it tells you exactly which card and why.
Traducido del English por IA ·
Una pregunta sobre la parte de webhooks. ¿«Reparado tras una caída» significa que las llamadas recibidas durante la caída se ejecutan después, o solo que el disparador vuelve a funcionar por sí mismo?
Question on the webhook part. Does «repaired after an outage» mean the calls that came in during the outage get run afterwards, or only that the trigger comes back by itself?
Water site sounds very close to my day job, tanks and pump stations. Is it included or does it need something extra on the plan?
Traducido del English por IA ·
Ambas opciones funcionan, tengo las dos en campo. En Bookworm es mucho menos complicado, NetworkManager hace el AP y el NAT de una sola vez:
sudo nmcli dev wifi hotspot ifname wlan0 ssid shed-iot password 'long-passphrase-here'
sudo nmcli con mod Hotspot connection.autoconnect yes ipv4.method shared
ipv4.method shared reparte DHCP a los ESP32 y les hace NAT a través de lo que tenga la ruta por defecto, tu dongle 4G. El Wi-Fi integrado de la Pi basta para 8 clientes a corta distancia.Donde yo lo pensaría dos veces es con el calor y las tarjetas SD, y además que nadie puede acceder a la Pi cuando se cuelga. Si eliges la Pi: caja metálica como disipador, una tarjeta SD industrial decente o un SSD USB, raíz de solo lectura si es posible, y el watchdog por hardware habilitado.Lo que un router con licencia te da en Hermetry por el dinero: lo reclamas con el código de su página Cloud local, inicia sesión con su propio certificado, puedes cambiar su configuración y actualizar su firmware desde Hermetry, y puedes abrir su panel web desde su página de dispositivo sin una IP fija, que en un enlace 4G no tendrás. Es un dispositivo de tu propia organización y cuenta una vez contra el límite de dispositivos. Las sesiones de acceso remoto tienen tiempo limitado y son auditadas.Mi regla: un sitio al que puedo ir en coche, Pi. Los sitios que necesitan una camioneta y un día, router con licencia. Detalles: Licensed gateways and Hermetry Edge.
Both work, I have both in the field. On Bookworm it’s much less fiddly, NetworkManager does the AP and the NAT in one go:
sudo nmcli dev wifi hotspot ifname wlan0 ssid shed-iot password 'long-passphrase-here'
sudo nmcli con mod Hotspot connection.autoconnect yes ipv4.method shared
ipv4.method shared hands out DHCP to the ESP32s and NATs them out of whatever has the default route, your 4G dongle. The Pi’s onboard Wi-Fi is fine for 8 clients at short range.
Where I’d think twice is heat and SD cards, plus nobody can reach the Pi when it hangs. If you go Pi: metal case as heatsink, a decent industrial SD or USB SSD, read-only root if you can, and the hardware watchdog enabled.
What a licensed router gives you on Hermetry for the money: you claim it with the code on its local Cloud page, it logs in with its own certificate, you can change its settings and update its firmware from Hermetry, and you can open its web panel from its device page without a fixed IP, which on a 4G link you won’t have. It’s a device in your org itself and counts once against the device limit. Remote access sessions are time-limited and audited.
My rule: one site I can drive to, Pi. Sites that need a ute and a day, licensed router. Details: Licensed gateways and Hermetry Edge.
Traducido del English por IA ·
¿VREF está conectada a 3,3 V? Si VREF está flotando, obtienes exactamente ese comportamiento de 0 / 1023.
Is VREF tied to 3.3 V? If VREF floats you get exactly that 0 / 1023 behaviour.
Complementary filter at 0.98 and a timer-driven loop, and it stands. Tuned it with P=18, D=0.6, a tiny I, plus a 6 % deadband. The 1 message per second batches at 20 Hz work, no more rate_limit, and the angle chart on the booth board looks great. My mistake was publishing from inside the control loop, every publish stretched the loop and made the oscillation worse too.
That explains the disconnects. So how do people get fast data for tuning, without getting kicked?
For 80 m and 12 nodes I’d not go I2C, even with extenders the capacitance adds up. CAN would work fine, MCP2515 boards are cheap. But RS-485 with Modbus is easier to debug with a USB dongle and a laptop.
Traducido del English por IA ·
Las claves caducan a los 90 días por defecto (un año como máximo), así que pon un recordatorio en algún sitio o tu atajo dejará de funcionar sin avisar en tres meses. Y mantén el archivo de claves con chmod 600, no en tu repositorio de dotfiles.
Keys expire after 90 days by default (a year at most), so put a reminder somewhere or your shortcut dies quietly in three months. And keep the key file chmod 600, not in your dotfiles repo.
Client’s mechanic welded simple guide rails onto the docks, and I changed the robot code to check charge current with 3 retries. Two weeks, one failed dock, and that one showed up red on the site view within a minute, so someone went over. Added Rachel’s battery alarm too.
No. It declares «docked» when the IR signal is strongest and stops.
NM is «not mounted», same as DNP (do not populate). The footprint is on the board but no part goes in it.
rc=2 is «client ID rejected». Colons are allowed in Hermetry client IDs (letters, digits and . _ : -, 1 to 64 chars), so it’s not the MAC format. Something else is getting into the ID.