jacksonmaker
@mariajackson · Se unió el mayo 2026
Maker · hobby projects · Hamilton
- Temas
- 1
- Respuestas
- 18
- Puntos
- 0
Respuestas de foro creadas
Traducido del English por IA ·
Ahora hay dos sitios, ambos OK. ¡Gracias!
Two sites now, both OK. Thanks!
Traducido del English por IA ·
Lo probé en mi propio espacio de trabajo y la tabla está vacía. Tengo dispositivos, pero nunca creé ningún sitio. ¿Supongo que ese es todo el problema?
Tried it on my own workspace and the table is empty. I have devices but I never made any sites. I’m guessing that’s the whole problem?
Which autopilot firmware and which port is free on it? Most have a second telemetry port meant for a companion computer.
Traducido del English por IA ·
Entonces, la red de invitados queda descartada. Lo hice para la panadería de mi hermana y dos cafeterías, todas con Ubiquiti, así que más o menos tu misma configuración:Crea un nuevo SSID «store-iot» con WPA2 PSK, asígnale su propia VLAN (digamos la 30), activa el aislamiento de clientes para que los sensores no puedan comunicarse entre sí, y en las reglas del firewall permite que esa VLAN solo salga hacia fuera: DNS, NTP y TCP 8883 hacia el broker de Hermetry (443 también si algo usa HTTPS). Bloquea la VLAN 30 hacia todas las demás redes internas. Eso es lo que quiere ver el auditor, y es una tarde por tienda.No añadiría una Pi para esto. Una Pi merece la pena cuando tus dispositivos no pueden llegar a internet por sí mismos (BLE, Modbus, Zigbee) y algo tiene que reportar por ellos como pasarela. Tus ESP32 ya hacen TLS por su cuenta; una Pi solo añadiría una tarjeta SD que puede fallar en la oficina trasera.En el lado de Hermetry, dos extras baratos: en el perfil del refrigerador, configura Allowed networks con la IP pública de cada tienda, así un token robado no sirve desde otro lugar. Y comprueba que Plain MQTT esté desactivado; solo TLS en 8883 es lo predeterminado, pero tu encargado de TI pudo haberlo activado durante las pruebas. La lista de verificación está al final de Device transport security.
Then guest is out. I did this for my sister’s bakery and two cafes, all Ubiquiti, so roughly your setup:
Make a new SSID «store-iot» with WPA2 PSK, tag it to its own VLAN (say 30), turn on client isolation so sensors can’t talk to each other, and in the firewall rules allow that VLAN only outbound: DNS, NTP, and TCP 8883 to the Hermetry broker (443 too if anything uses HTTPS). Block VLAN 30 to every other internal network. That’s what the auditor wants to see, and it’s one afternoon per store.
I wouldn’t add a Pi for this. A Pi is worth it when your devices can’t reach the internet themselves (BLE, Modbus, Zigbee) and something has to report for them as a gateway. Your ESP32s already do TLS on their own, a Pi just adds an SD card that can die in the back office.
On the Hermetry side two cheap extras: on the fridge profile set Allowed networks to each store’s public IP, so a stolen token is useless from anywhere else. And check Plain MQTT is off, TLS only on 8883 is the default but your IT guy may have turned it on while testing. Checklist at the bottom of Device transport security.
Following. I’ve never touched FSK mode at all.
Traducido del English por IA ·
Zigbee en casa funciona bien en malla para mí, cada enchufe conectado a la red se convierte en un router. Desde entonces nunca he tenido una esquina sin cobertura.
Zigbee at home meshes fine for me, every mains-powered plug becomes a router. Never had a dead corner since.
I went down this hole for a garden sensor last year and the answer turned out to be energy per job, not current.
A battery device spends 99.9% of its life asleep. What empties the battery is (sleep current × sleep time) + (active current × awake time) + the radio. The core width hardly matters for sleep current: that’s set by the process the chip is made on, the RTC, the RAM retention and leakage. Modern 32-bit low power parts are made on newer, leakier-in-theory but better-managed processes with power domains you can switch off, and their sleep currents with RTC running are around 1 µA or less. An ATmega328P in power-down with the watchdog running is in the same ballpark at best, and with brown-out detection on, worse.
When awake, a 32-bit core finishes the job faster. Reading a 16-bit ADC result, doing a few multiplications for RMS current and building a packet is many more instructions on an 8-bit AVR than on a Cortex-M0+, at similar µA/MHz. Fewer cycles means less time awake, so less energy, even if the current while running is similar.
And the peripherals: the low power ARM parts can run the ADC, DMA and timers while the core sleeps, so the core wakes once with the result ready.
In my case the MCU choice turned out to be noise next to the radio: one LoRa transmit costs more than an hour of MCU sleep. Spend your effort on how often you send.
Traducido del English por IA ·
Para el estudio de cobertura: lleva un sensor de prueba y observa el registro de tramas. El RSSI y el SNR por trama me dijeron más que cualquier mapa de cobertura.
For the survey: carry one test sensor around and watch the frames log. RSSI and SNR per frame told me more than any coverage map.
HC-06 default is 9600. Is your sketch on 115200?
Way over my head but following, the tank-and-pump setup is the same as my rainwater barrel lol
Even with a null at the end, atoi on {«method»:… gives 0 because the first character is a brace. You need to parse the JSON.
Traducido del English por IA ·
CE0 frente a CE1, por supuesto. CS estaba en el pin 24 y el código decía 1. Lo cambié a spi.open(0, 0) y el canal 0 ahora lee 412 con el tanque medio lleno, el canal 1 flota como debe. La prueba de loopback también pasó, así que me quedo con esa. Ahora envío mA y escalo en el flujo, como dijo twilson.
CE0 vs CE1, of course. CS was on pin 24 and the code said 1. Changed it to spi.open(0, 0) and channel 0 now reads 412 with the tank half full, channel 1 floats like it should. Loopback test passed too, so I’ll keep that one. Sending mA now and scaling in the flow as twilson said.
Traducido del English por IA ·
VREF y VDD están ambos a 3,3 V, AGND y DGND están a tierra. Lo he comprobado dos veces.
VREF and VDD both on 3.3 V, AGND and DGND on ground. Checked twice.
Traducido del English por IA ·
Los huecos de exactamente la duración de la caída parecen indicar que no se publicó nada durante la caída, y no que el broker los perdiera. ¿Tu cliente encola siquiera los mensajes mientras está desconectado?
Gaps of exactly the outage length sounds like nothing was published at all during the outage, not like the broker lost them. Is your client even queuing while disconnected?
Traducido del English por IA ·
Estoy bastante seguro de que la Pi no conecta los pines HEC en absoluto, pero nunca lo he comprobado como es debido.
Pretty sure the Pi doesn’t wire up the HEC pins at all, but I’ve never checked properly.