Novedad: el cortafuegos de IA supervisa toda la plataforma y explica cada incidente con palabras sencillas. Vea cómo funciona

Reply To: BLE tags draw 40 uA asleep instead of 2, and Hermetry shows them offline between reports

Logging and serial off plus DC/DC: 3.1 uA on the bench. Gateway now waits 5 minutes before disconnect, and the offline rule opens after 15 minutes. Zero offline alarms since Tuesday, and the battery estimate is back over two years.

Ground loops are my cardio.
♥ 1